BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

801 related articles for article (PubMed ID: 18192074)

  • 1. Efficacy of point-of-entry copper--silver ionisation system in eradicating Legionella pneumophila in a tropical tertiary care hospital: implications for hospitals contaminated with Legionella in both hot and cold water.
    Chen YS; Lin YE; Liu YC; Huang WK; Shih HY; Wann SR; Lee SS; Tsai HC; Li CH; Chao HL; Ke CM; Lu HH; Chang CL
    J Hosp Infect; 2008 Feb; 68(2):152-8. PubMed ID: 18192074
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Abbreviated duration of superheat-and-flush and disinfection of taps for Legionella disinfection: lessons learned from failure.
    Chen YS; Liu YC; Lee SS; Tsai HC; Wann SR; Kao CH; Chang CL; Huang WK; Huang TS; Chao HL; Li CH; Ke CM; Lin YS
    Am J Infect Control; 2005 Dec; 33(10):606-10. PubMed ID: 16330310
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Controlling Legionella in hospital water systems: experience with the superheat-and-flush method and copper-silver ionization.
    Stout JE; Lin YS; Goetz AM; Muder RR
    Infect Control Hosp Epidemiol; 1998 Dec; 19(12):911-4. PubMed ID: 9872527
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experiences of the first 16 hospitals using copper-silver ionization for Legionella control: implications for the evaluation of other disinfection modalities.
    Stout JE; Yu VL
    Infect Control Hosp Epidemiol; 2003 Aug; 24(8):563-8. PubMed ID: 12940575
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prevention of Legionnaires' disease in hospitals.
    Sarjomaa M; Urdahl P; Ramsli E; Borchgrevink-Lund CF; Ask E
    Tidsskr Nor Laegeforen; 2011 Aug; 131(16):1554-7. PubMed ID: 21866196
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Water disinfection with ozone, copper and silver ions, and temperature increase to control Legionella: seven years of experience in a university teaching hospital.
    Blanc DS; Carrara P; Zanetti G; Francioli P
    J Hosp Infect; 2005 May; 60(1):69-72. PubMed ID: 15823660
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Outbreak of hospital acquired Legionnaires' disease in patients of ophthalmic ward. Nosocomial Legionella infections for the first time observed in Poland].
    Stypułkowska-Misiurewicz H; Pancer K; Krogulska B; Matuszewska R
    Przegl Epidemiol; 2007; 61(4):657-65. PubMed ID: 18572497
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Disinfection of water distribution systems for Legionella.
    Lin YS; Stout JE; Yu VL; Vidic RD
    Semin Respir Infect; 1998 Jun; 13(2):147-59. PubMed ID: 9643393
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prolonged effect of two combined methods for Legionella disinfection in a hospital water system.
    Casari E; Ferrario A; Montanelli A
    Ann Ig; 2007; 19(6):525-32. PubMed ID: 18376573
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Four years of experience with silver-copper ionization for control of legionella in a german university hospital hot water plumbing system.
    Rohr U; Senger M; Selenka F; Turley R; Wilhelm M
    Clin Infect Dis; 1999 Dec; 29(6):1507-11. PubMed ID: 10585804
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hospital-acquired legionnaires disease in a university hospital: impact of the copper-silver ionization system.
    Mòdol J; Sabrià M; Reynaga E; Pedro-Botet ML; Sopena N; Tudela P; Casas I; Rey-Joly C
    Clin Infect Dis; 2007 Jan; 44(2):263-5. PubMed ID: 17173228
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Management of the Legionella-link risk in a multicentre area's hospital: lessons learned of a six-year experience].
    Lecointe D; Fagundez E; Pierron P; Musset JP; Brissé P; Vollereau D; Breton D; Théodora C; Beauvais R; Malbrunot C; Crine L; Fèvre C;
    Pathol Biol (Paris); 2010 Apr; 58(2):131-6. PubMed ID: 19875245
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Prevention and control of Legionella infection in the hospital environment].
    Borella P; Bargellini A; Pergolizzi S; Aggazzotti G; Curti C; Nizzero P; Stancanelli G; Vaiani R; Gesù G; Mazzuconi R
    Ann Ig; 2000; 12(4):287-96. PubMed ID: 11140095
    [TBL] [Abstract][Full Text] [Related]  

  • 14. From legionnaire to guerrilla combatant: suppression of Legionella pneumophila in a hospital cold water supply.
    Wagenvoort JH; Sijstermans ML
    J Hosp Infect; 2004 Oct; 58(2):162-3. PubMed ID: 15474192
    [No Abstract]   [Full Text] [Related]  

  • 15. Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 degrees C: experience from a 10-year surveillance programme in a district general hospital.
    Darelid J; Löfgren S; Malmvall BE
    J Hosp Infect; 2002 Mar; 50(3):213-9. PubMed ID: 11886198
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Silver/copper ionisation treatment of water to reduce the risk of Legionella in NHS healthcare premises. Water Quality Working Group-4.
    Dobson C; Griffiths D; Thomas S; Lee J
    Health Estate J; 1997 May; 51(4):7-8, 10. PubMed ID: 10169415
    [No Abstract]   [Full Text] [Related]  

  • 17. Use of terminal tap water filter systems for prevention of nosocomial legionellosis.
    Vonberg RP; Eckmanns T; Bruderek J; Rüden H; Gastmeier P
    J Hosp Infect; 2005 Jun; 60(2):159-62. PubMed ID: 15866015
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Cold tap water as a source of fatal nosocomial pneumonia due to Legionella pneumophila in a rehabilitation center].
    Hoebe CJ; Cluitmans JJ; Wagenvoort JH; van Leeuwen WJ; Bilkert-Mooiman MA
    Ned Tijdschr Geneeskd; 1999 May; 143(20):1041-5. PubMed ID: 10368731
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Point-of-care controls for nosocomial legionellosis combined with chlorine dioxide potable water decontamination: a two-year survey at a Welsh teaching hospital.
    Hosein IK; Hill DW; Tan TY; Butchart EG; Wilson K; Finlay G; Burge S; Ribeiro CD
    J Hosp Infect; 2005 Oct; 61(2):100-6. PubMed ID: 16002178
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A 17-month evaluation of a chlorine dioxide water treatment system to control Legionella species in a hospital water supply.
    Srinivasan A; Bova G; Ross T; Mackie K; Paquette N; Merz W; Perl TM
    Infect Control Hosp Epidemiol; 2003 Aug; 24(8):575-9. PubMed ID: 12940577
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 41.