342 related articles for article (PubMed ID: 18199904)
21. Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies.
Reilhac A; Tomeï S; Buvat I; Michel C; Keheren F; Costes N
Neuroimage; 2008 Jan; 39(1):359-68. PubMed ID: 17920931
[TBL] [Abstract][Full Text] [Related]
22. Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction.
Karakatsanis NA; Casey ME; Lodge MA; Rahmim A; Zaidi H
Phys Med Biol; 2016 Aug; 61(15):5456-85. PubMed ID: 27383991
[TBL] [Abstract][Full Text] [Related]
23. Direct 4D parametric imaging for linearized models of reversibly binding PET tracers using generalized AB-EM reconstruction.
Rahmim A; Zhou Y; Tang J; Lu L; Sossi V; Wong DF
Phys Med Biol; 2012 Feb; 57(3):733-55. PubMed ID: 22252120
[TBL] [Abstract][Full Text] [Related]
24. Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality.
Brasse D; Kinahan PE; Lartizien C; Comtat C; Casey M; Michel C
J Nucl Med; 2005 May; 46(5):859-67. PubMed ID: 15872361
[TBL] [Abstract][Full Text] [Related]
25. Model-based image reconstruction for four-dimensional PET.
Li T; Thorndyke B; Schreibmann E; Yang Y; Xing L
Med Phys; 2006 May; 33(5):1288-98. PubMed ID: 16752564
[TBL] [Abstract][Full Text] [Related]
26. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.
Holen RV; Vandenberghe S; Staelens S; De Beenhouwer J; Lemahieu I
Phys Med Biol; 2009 Feb; 54(3):715-29. PubMed ID: 19131666
[TBL] [Abstract][Full Text] [Related]
27. Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.
Tsoumpas C; Turkheimer FE; Thielemans K
Med Phys; 2008 Apr; 35(4):1299-309. PubMed ID: 18491524
[TBL] [Abstract][Full Text] [Related]
28. Mean and covariance properties of dynamic PET reconstructions from list-mode data.
Asma E; Leahy RM
IEEE Trans Med Imaging; 2006 Jan; 25(1):42-54. PubMed ID: 16398413
[TBL] [Abstract][Full Text] [Related]
29. Dynamic positron emission tomography data-driven analysis using sparse Bayesian learning.
Peng JY; Aston JA; Gunn RN; Liou CY; Ashburner J
IEEE Trans Med Imaging; 2008 Sep; 27(9):1356-69. PubMed ID: 18753048
[TBL] [Abstract][Full Text] [Related]
30. Gap compensation during PET image reconstruction by constrained, total variation minimization.
Ahn S; Kim SM; Son J; Lee DS; Sung Lee J
Med Phys; 2012 Feb; 39(2):589-602. PubMed ID: 22320768
[TBL] [Abstract][Full Text] [Related]
31. Three-dimensional maximum a posteriori (MAP) imaging with radiopharmaceuticals labeled with three Cu radionuclides.
Ruangma A; Bai B; Lewis JS; Sun X; Welch MJ; Leahy R; Laforest R
Nucl Med Biol; 2006 Feb; 33(2):217-26. PubMed ID: 16546676
[TBL] [Abstract][Full Text] [Related]
32. A new method for PET image reconstruction using Fourier-Wavelet moment.
Hu Y; Zhou J; Shu H; Luo L; Coatrieux JL
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():2546-9. PubMed ID: 17946521
[TBL] [Abstract][Full Text] [Related]
33. Impact of time-of-flight on indirect 3D and direct 4D parametric image reconstruction in the presence of inconsistent dynamic PET data.
Kotasidis FA; Mehranian A; Zaidi H
Phys Med Biol; 2016 May; 61(9):3443-71. PubMed ID: 27049697
[TBL] [Abstract][Full Text] [Related]
34. Image segmentation and activity estimation for microPET 11C-raclopride images using an expectation-maximum algorithm with a mixture of Poisson distributions.
Su KH; Chen JS; Lee JS; Hu CM; Chang CW; Chou YH; Liu RS; Chen JC
Comput Med Imaging Graph; 2011 Jul; 35(5):417-26. PubMed ID: 21288690
[TBL] [Abstract][Full Text] [Related]
35. Image derived input functions for dynamic High Resolution Research Tomograph PET brain studies.
Mourik JE; van Velden FH; Lubberink M; Kloet RW; van Berckel BN; Lammertsma AA; Boellaard R
Neuroimage; 2008 Dec; 43(4):676-86. PubMed ID: 18707007
[TBL] [Abstract][Full Text] [Related]
36. Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA.
Cui JY; Pratx G; Prevrhal S; Levin CS
Med Phys; 2011 Dec; 38(12):6775-86. PubMed ID: 22149859
[TBL] [Abstract][Full Text] [Related]
37. A fast fully 4-D incremental gradient reconstruction algorithm for list mode PET data.
Li Q; Asma E; Ahn S; Leahy RM
IEEE Trans Med Imaging; 2007 Jan; 26(1):58-67. PubMed ID: 17243584
[TBL] [Abstract][Full Text] [Related]
38. 18F-CPFPX PET: on the generation of parametric images and the effect of scan duration.
Meyer PT; Elmenhorst D; Matusch A; Winz O; Zilles K; Bauer A
J Nucl Med; 2006 Feb; 47(2):200-7. PubMed ID: 16455624
[TBL] [Abstract][Full Text] [Related]
39. Variational segmentation of vector-valued images with gradient vector flow.
Jaouen V; González P; Stute S; Guilloteau D; Chalon S; Buvat I; Tauber C
IEEE Trans Image Process; 2014 Nov; 23(11):4773-85. PubMed ID: 25203991
[TBL] [Abstract][Full Text] [Related]
40. Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors.
Alessio AM; Kinahan PE
Med Phys; 2006 Nov; 33(11):4095-103. PubMed ID: 17153389
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]