153 related articles for article (PubMed ID: 18204330)
1. The Cleveland Clinic PediPump: virtual fitting studies in children using three-dimensional reconstructions of cardiac computed tomography scans.
Saeed D; Ootaki Y; Noecker A; Weber S; Smith WA; Duncan BW; Fukamachi K
ASAIO J; 2008; 54(1):133-7. PubMed ID: 18204330
[TBL] [Abstract][Full Text] [Related]
2. The Cleveland Clinic PediPump: anatomic modeling and virtual fitting studies in a lamb model.
Noecker AM; Cingoz F; Ootaki Y; Liu J; Kuzmiak S; Kopcak MW; Fukamachi K; Duncan BW
ASAIO J; 2007; 53(6):716-9. PubMed ID: 18043154
[TBL] [Abstract][Full Text] [Related]
3. Development of patient-specific three-dimensional pediatric cardiac models.
Noecker AM; Chen JF; Zhou Q; White RD; Kopcak MW; Arruda MJ; Duncan BW
ASAIO J; 2006; 52(3):349-53. PubMed ID: 16760727
[TBL] [Abstract][Full Text] [Related]
4. The practical clinical value of three-dimensional models of complex congenitally malformed hearts.
Riesenkampff E; Rietdorf U; Wolf I; Schnackenburg B; Ewert P; Huebler M; Alexi-Meskishvili V; Anderson RH; Engel N; Meinzer HP; Hetzer R; Berger F; Kuehne T
J Thorac Cardiovasc Surg; 2009 Sep; 138(3):571-80. PubMed ID: 19698837
[TBL] [Abstract][Full Text] [Related]
5. Cleveland Clinic PediPump lamb cadaver fitting studies.
Cingoz F; Fukamachi K; Ootaki Y; Kamohara K; Akiyama M; Ootaki C; Kopcak MW; Liu J; Noecker A; Dudzinski D; Smith WA; Duncan BW
Artif Organs; 2007 May; 31(5):405-8. PubMed ID: 17470212
[TBL] [Abstract][Full Text] [Related]
6. The PediPump: a versatile, implantable pediatric ventricular assist device-update III.
Weber S; Dudzinski DT; Gu L; Mielke N; Casas F; Noecker AM; Saeed D; Ootaki Y; Fukamachi K; Smith WA; Duncan BW
ASAIO J; 2007; 53(6):730-3. PubMed ID: 18043157
[TBL] [Abstract][Full Text] [Related]
7. Three-dimensional visualization and virtual simulation of resections in pediatric solid tumors.
Fuchs J; Warmann SW; Szavay P; Kirschner HJ; Schäfer JF; Hennemuth A; Scheel-Walter HG; Bourquain H; Peitgen HO
J Pediatr Surg; 2005 Feb; 40(2):364-70. PubMed ID: 15750930
[TBL] [Abstract][Full Text] [Related]
8. [Study on the methods for establishing virtual three-dimensional models of cerebral arteries with the three-dimensional moulding software].
Wei X; Xie X; Wang C
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Dec; 24(6):1246-9. PubMed ID: 18232470
[TBL] [Abstract][Full Text] [Related]
9. The PediPump: a new ventricular assist device for children.
Duncan BW; Lorenz M; Kopcak MW; Fukamachi K; Ootaki Y; Chen HM; Chapman PA; Davis SJ; Smith WA
Artif Organs; 2005 Jul; 29(7):527-30. PubMed ID: 15982280
[TBL] [Abstract][Full Text] [Related]
10. [The use of open source software in graphic anatomic reconstructions and in biomechanic simulations].
Ciobanu O
Rev Med Chir Soc Med Nat Iasi; 2009; 113(3):927-33. PubMed ID: 20191857
[TBL] [Abstract][Full Text] [Related]
11. The use of stereolithographic hand held models for evaluation of congenital anomalies of the great arteries.
Vranicar M; Gregory W; Douglas WI; Di Sessa P; Di Sessa TG
Stud Health Technol Inform; 2008; 132():538-43. PubMed ID: 18391364
[TBL] [Abstract][Full Text] [Related]
12. Physical models aiding in complex congenital heart surgery.
Mottl-Link S; Hübler M; Kühne T; Rietdorf U; Krueger JJ; Schnackenburg B; De Simone R; Berger F; Juraszek A; Meinzer HP; Karck M; Hetzer R; Wolf I
Ann Thorac Surg; 2008 Jul; 86(1):273-7. PubMed ID: 18573436
[TBL] [Abstract][Full Text] [Related]
13. The PediPump: development status of a new pediatric ventricular assist device: update II.
Duncan BW; Dudzinski DT; Gu L; Mielke N; Noecker AM; Kopcak MW; Fukamachi K; Cingoz F; Ootaki Y; Smith WA
ASAIO J; 2006; 52(5):581-7. PubMed ID: 16966863
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of virtual reality and stereolithographic models in maxillo-facial surgical planning.
Robiony M; Salvo I; Costa F; Zerman N; Bandera C; Filippi S; Felice M; Politi M
J Craniofac Surg; 2008 Mar; 19(2):482-9. PubMed ID: 18362729
[TBL] [Abstract][Full Text] [Related]
15. Surgical planning for microsurgical excision of cerebral arterio-venous malformations using virtual reality technology.
Ng I; Hwang PY; Kumar D; Lee CK; Kockro RA; Sitoh YY
Acta Neurochir (Wien); 2009 May; 151(5):453-63; discussion 463. PubMed ID: 19319471
[TBL] [Abstract][Full Text] [Related]
16. The visible ear simulator: a public PC application for GPU-accelerated haptic 3D simulation of ear surgery based on the visible ear data.
Sorensen MS; Mosegaard J; Trier P
Otol Neurotol; 2009 Jun; 30(4):484-7. PubMed ID: 19546800
[TBL] [Abstract][Full Text] [Related]
17. Virtual study models: a comparison of modular application systems.
Favero L; Terrazzani C; Favero V; Stellini E; Cocilovo F
Prog Orthod; 2009; 10(2):16-25. PubMed ID: 20545088
[TBL] [Abstract][Full Text] [Related]
18. Accuracy of craniofacial measurements: computed tomography and three-dimensional computed tomography compared with stereolithographic models.
Frühwald J; Schicho KA; Figl M; Benesch T; Watzinger F; Kainberger F
J Craniofac Surg; 2008 Jan; 19(1):22-6. PubMed ID: 18216660
[TBL] [Abstract][Full Text] [Related]
19. Three-dimensional localization of implanted biomaterials in anatomical and histological specimens using combined X-ray computed tomography and three-dimensional surface reconstruction: a technical note.
Cuijpers VM; Walboomers XF; Jansen JA
Tissue Eng Part C Methods; 2010 Feb; 16(1):63-9. PubMed ID: 19358629
[TBL] [Abstract][Full Text] [Related]
20. Dynamic computed tomography to determine cardiac output in patients with left ventricular assist devices.
Raman SV; Tran T; Simonetti OP; Sun B
J Thorac Cardiovasc Surg; 2009 May; 137(5):1213-7. PubMed ID: 19379994
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]