BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 18212477)

  • 1. Efficiency of a tool-mounted local exhaust ventilation system for controlling dust exposure during metal grinding operations.
    Ojima J
    Ind Health; 2007 Dec; 45(6):817-9. PubMed ID: 18212477
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effectiveness of dust control methods for crystalline silica and respirable suspended particulate matter exposure during manual concrete surface grinding.
    Akbar-Khanzadeh F; Milz SA; Wagner CD; Bisesi MS; Ames AL; Khuder S; Susi P; Akbar-Khanzadeh M
    J Occup Environ Hyg; 2010 Dec; 7(12):700-11. PubMed ID: 21058155
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An evaluation of on-tool shrouds for controlling respirable crystalline silica in restoration stone work.
    Healy CB; Coggins MA; Van Tongeren M; MacCalman L; McGowan P
    Ann Occup Hyg; 2014 Nov; 58(9):1155-67. PubMed ID: 25261456
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Crystalline silica dust and respirable particulate matter during indoor concrete grinding - wet grinding and ventilated grinding compared with uncontrolled conventional grinding.
    Akbar-Khanzadeh F; Milz S; Ames A; Susi PP; Bisesi M; Khuder SA; Akbar-Khanzadeh M
    J Occup Environ Hyg; 2007 Oct; 4(10):770-9. PubMed ID: 17763068
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Metal dust exposure and control in hand-held grinding operation].
    Ojima J
    Sangyo Eiseigaku Zasshi; 2007 Jan; 49(1):9-11. PubMed ID: 17303933
    [No Abstract]   [Full Text] [Related]  

  • 6. Experimental Evaluation of Respirable Dust and Crystalline Silica Controls During Simulated Performance of Stone Countertop Fabrication Tasks With Powered Hand Tools.
    Johnson DL; Phillips ML; Qi C; Van AT; Hawley DA
    Ann Work Expo Health; 2017 Jul; 61(6):711-723. PubMed ID: 28927166
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reducing silica and dust exposures in construction during use of powered concrete-cutting hand tools: efficacy of local exhaust ventilation on hammer drills.
    Shepherd S; Woskie SR; Holcroft C; Ellenbecker M
    J Occup Environ Hyg; 2009 Jan; 6(1):42-51. PubMed ID: 19005968
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Control of Dust Dispersion From an Enclosed Renovation Site Into Adjacent Areas by Using Local Exhaust Ventilation.
    Kokkonen A; Linnainmaa M; Säämänen A; Kanerva T; Sorvari J; Kolehmainen M; Lappalainen V; Pasanen P
    Ann Work Expo Health; 2019 Apr; 63(4):468-479. PubMed ID: 30877765
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An evaluation of an aftermarket local exhaust ventilation device for suppressing respirable dust and respirable crystalline silica dust from powered saws.
    Garcia A; Jones E; Echt AS; Hall RM
    J Occup Environ Hyg; 2014; 11(11):D200-7. PubMed ID: 25148513
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of hollow bit local exhaust ventilation on respirable quartz dust concentrations during concrete drilling.
    Rempel D; Barr A; Cooper MR
    J Occup Environ Hyg; 2019 May; 16(5):336-340. PubMed ID: 31013200
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities.
    Croteau GA; Guffey SE; Flanagan ME; Seixas NS
    AIHA J (Fairfax, Va); 2002; 63(4):458-67. PubMed ID: 12486779
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The efficacy of local exhaust ventilation for controlling dust exposures during concrete surface grinding.
    Croteau GA; Flanagan ME; Camp JE; Seixas NS
    Ann Occup Hyg; 2004 Aug; 48(6):509-18. PubMed ID: 15298850
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laboratory evaluation to reduce respirable crystalline silica dust when cutting concrete roofing tiles using a masonry saw.
    Carlo RV; Sheehy J; Feng HA; Sieber WK
    J Occup Environ Hyg; 2010 Apr; 7(4):245-51. PubMed ID: 20169490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Designing, construction, assessment, and efficiency of local exhaust ventilation in controlling crystalline silica dust and particles, and formaldehyde in a foundry industry plant.
    Morteza MM; Hossein K; Amirhossein M; Naser H; Gholamhossein H; Hossein F
    Arh Hig Rada Toksikol; 2013; 64(1):123-31. PubMed ID: 23585164
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Task-specific noise exposure during manual concrete surface grinding in enclosed areas-influence of operation variables and dust control methods.
    Akbar-Khanzadeh F; Ames AL; Milz SA; Akbar-Khanzadeh M
    J Occup Environ Hyg; 2013; 10(9):478-86. PubMed ID: 23926952
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of air distribution on efficiency of dust capture from metal grinding--bench test method.
    Jankowski T
    Ind Health; 2011; 49(6):735-45. PubMed ID: 22020017
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement.
    Echt A; Mead K
    Ann Occup Hyg; 2016 May; 60(4):519-24. PubMed ID: 26826033
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Respirable silica dust suppression during artificial stone countertop cutting.
    Cooper JH; Johnson DL; Phillips ML
    Ann Occup Hyg; 2015 Jan; 59(1):122-6. PubMed ID: 25326187
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A numerical and experimental investigation of crystalline silica exposure control during tuck pointing.
    Heitbrink W; Bennett J
    J Occup Environ Hyg; 2006 Jul; 3(7):366-78. PubMed ID: 16835163
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Respirable dust control in grinding gray iron castings.
    O'Brien D; Baron P; Willeke K
    Am Ind Hyg Assoc J; 1987 Feb; 48(2):181-7. PubMed ID: 3031975
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.