These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 18214649)

  • 1. Experiment study on fracture fixation with low rigidity titanium alloy: plate fixation of tibia fracture model in rabbit.
    Sumitomo N; Noritake K; Hattori T; Morikawa K; Niwa S; Sato K; Niinomi M
    J Mater Sci Mater Med; 2008 Apr; 19(4):1581-6. PubMed ID: 18214649
    [TBL] [Abstract][Full Text] [Related]  

  • 2. β-type TiNbSn Alloy Plates With Low Young Modulus Accelerates Osteosynthesis in Rabbit Tibiae.
    Ito K; Mori Y; Kamimura M; Koguchi M; Kurishima H; Koyama T; Mori N; Masahashi N; Hanada S; Itoi E; Aizawa T
    Clin Orthop Relat Res; 2022 Sep; 480(9):1817-1832. PubMed ID: 35543573
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of elastic intramedullary nails composed of low Young's modulus Ti-Nb-Sn alloy on healing of tibial osteotomies in rabbits.
    Kogure A; Mori Y; Tanaka H; Kamimura M; Masahashi N; Hanada S; Itoi E
    J Biomed Mater Res B Appl Biomater; 2019 Apr; 107(3):700-707. PubMed ID: 29920923
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparative biomechanical evaluation of a noncontacting plate and currently used devices for tibial fixation.
    Kowalski MJ; Schemitsch EH; Harrington RM; Chapman JR; Swiontkowski MF
    J Trauma; 1996 Jan; 40(1):5-9. PubMed ID: 8576998
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of plate design on cortical bone perfusion and fracture healing in canine segmental tibial fractures.
    Jain R; Podworny N; Hupel TM; Weinberg J; Schemitsch EH
    J Orthop Trauma; 1999; 13(3):178-86. PubMed ID: 10206249
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Histological and radiographic evaluations of demineralized bone matrix and coralline hydroxyapatite in the rabbit tibia.
    Zhukauskas R; Dodds RA; Hartill C; Arola T; Cobb RR; Fox C
    J Biomater Appl; 2010 Mar; 24(7):639-56. PubMed ID: 19581323
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.
    Jain R; Podworny N; Hearn T; Anderson GI; Schemitsch EH
    J Orthop Trauma; 1997 Oct; 11(7):490-5. PubMed ID: 9334950
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Novel Shape Memory Plate Osteosynthesis for Noninvasive Modulation of Fixation Stiffness in a Rabbit Tibia Osteotomy Model.
    Müller CW; Pfeifer R; Meier K; Decker S; Reifenrath J; Gösling T; Wesling V; Krettek C; Hurschler C; Krämer M
    Biomed Res Int; 2015; 2015():652940. PubMed ID: 26167493
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Structural design and evaluation of bone remodeling effect of fracture internal fixation implants with time-varying stiffness].
    Sun H; Ding X; Xu S; Duan P; Xiong M; Zhang H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2024 Jun; 41(3):595-603. PubMed ID: 38932547
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of intramedullary nails composed of a new β-type Ti-Nb-Sn alloy with low Young's modulus on fracture healing in mouse tibiae.
    Fujisawa H; Mori Y; Kogure A; Tanaka H; Kamimura M; Masahashi N; Hanada S; Itoi E
    J Biomed Mater Res B Appl Biomater; 2018 Nov; 106(8):2841-2848. PubMed ID: 29360240
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bone bonding ability of a chemically and thermally treated low elastic modulus Ti alloy: gum metal.
    Tanaka M; Takemoto M; Fujibayashi S; Kawai T; Yamaguchi S; Kizuki T; Matsushita T; Kokubo T; Nakamura T; Matsuda S
    J Mater Sci Mater Med; 2014 Mar; 25(3):635-43. PubMed ID: 24293215
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical and histological evaluation of the application of biodegradable poly-L-lactic cushion to the plate internal fixation for bone fracture healing.
    Fan Y; Xiu K; Duan H; Zhang M
    Clin Biomech (Bristol, Avon); 2008; 23 Suppl 1():S7-S16. PubMed ID: 18291564
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bone healing after metal plate fixation and external fixation of the osteotomized rabbit tibia.
    Terjesen T
    Acta Orthop Scand; 1984 Feb; 55(1):69-77. PubMed ID: 6702434
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro and in vivo biological performance of porous Ti alloys prepared by powder metallurgy.
    do Prado RF; Esteves GC; Santos ELS; Bueno DAG; Cairo CAA; Vasconcellos LGO; Sagnori RS; Tessarin FBP; Oliveira FE; Oliveira LD; Villaça-Carvalho MFL; Henriques VAR; Carvalho YR; De Vasconcellos LMR
    PLoS One; 2018; 13(5):e0196169. PubMed ID: 29771925
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrastructural differences of the interface zone between bone and Ti 6Al 4V or commercially pure titanium.
    Johansson C; Lausmaa J; Ask M; Hansson HA; Albrektsson T
    J Biomed Eng; 1989 Jan; 11(1):3-8. PubMed ID: 2927096
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young's modulus.
    Miura K; Yamada N; Hanada S; Jung TK; Itoi E
    Acta Biomater; 2011 May; 7(5):2320-6. PubMed ID: 21316491
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vivo investigation of calcium phosphate coatings on Ti6-Al-4V alloy substrates using lactic acid - sodium lactate buffered synthetic body fluid.
    Havitçioğlu H; Ceçen B; Pasinli A; Yüksel M; Aydin I; Yildiz H
    Acta Orthop Traumatol Turc; 2013; 47(6):417-22. PubMed ID: 24509222
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Incorporating simvastatin/poloxamer 407 hydrogel into 3D-printed porous Ti
    Liu H; Li W; Liu C; Tan J; Wang H; Hai B; Cai H; Leng HJ; Liu ZJ; Song CL
    Biofabrication; 2016 Oct; 8(4):045012. PubMed ID: 27788122
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Bone remodeling after internal fixation with different stiffness plates: ultrastructural investigation].
    Chen YQ
    Zhonghua Wai Ke Za Zhi; 1991 Apr; 29(4):256-9, 272. PubMed ID: 1874119
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bioactivity of Ti-6Al-4V alloy implants treated with ibandronate after the formation of the nanotube TiO2 layer.
    Moon SH; Lee SJ; Park IS; Lee MH; Soh YJ; Bae TS; Kim HS
    J Biomed Mater Res B Appl Biomater; 2012 Nov; 100(8):2053-9. PubMed ID: 22915455
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.