These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
70 related articles for article (PubMed ID: 18218516)
21. Study of PET intrinsic spatial resolution and contrast recovery improvement for PET/MRI systems. Peng H; Levin CS Phys Med Biol; 2012 May; 57(9):N101-15. PubMed ID: 22481596 [TBL] [Abstract][Full Text] [Related]
22. NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner. Prasad R; Ratib O; Zaidi H Phys Med Biol; 2011 Oct; 56(20):6649-64. PubMed ID: 21941029 [TBL] [Abstract][Full Text] [Related]
23. PET with a dual-head coincidence camera: spatial resolution, scatter fraction, and sensitivity. Kunze WD; Baehre M; Richter E J Nucl Med; 2000 Jun; 41(6):1067-74. PubMed ID: 10855637 [TBL] [Abstract][Full Text] [Related]
24. Performance of QPET, a high-resolution 3D PET imaging system for small volumes. McKee BA; Dickson AW; Howse DC IEEE Trans Med Imaging; 1994; 13(1):176-85. PubMed ID: 18218495 [TBL] [Abstract][Full Text] [Related]
25. [Investigation of the signal-to-noise ratio on a state-of-the-art PET system: measurements with the EEC whole-body phantom]. Jägel M; Adam LE; Bellemann ME; Zaers J; Trojan H; Rauschnabel K; Brix G Nuklearmedizin; 1998 Aug; 37(5):171-6. PubMed ID: 9728344 [TBL] [Abstract][Full Text] [Related]
26. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography. Roessl E; Brendel B; Engel KJ; Schlomka JP; Thran A; Proksa R IEEE Trans Med Imaging; 2011 Sep; 30(9):1678-90. PubMed ID: 21507770 [TBL] [Abstract][Full Text] [Related]
27. Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application. Shikhaliev PM; Fritz SG Phys Med Biol; 2011 Apr; 56(7):1905-30. PubMed ID: 21364268 [TBL] [Abstract][Full Text] [Related]
28. Energy dependence of nonstationary scatter subtraction--restoration in high resolution PET. Bentourkia M; Lecomte R IEEE Trans Med Imaging; 1999 Jan; 18(1):66-73. PubMed ID: 10193698 [TBL] [Abstract][Full Text] [Related]
29. Design features and performance of a PET system for animal research. Cutler PD; Cherry SR; Hoffman EJ; Digby WM; Phelps ME J Nucl Med; 1992 Apr; 33(4):595-604. PubMed ID: 1552348 [TBL] [Abstract][Full Text] [Related]
30. Energy dependence of scatter components in multispectral PET imaging. Bentourkia M; Msaki P; Cadorette J; Lecomte R IEEE Trans Med Imaging; 1995; 14(1):138-45. PubMed ID: 18215818 [TBL] [Abstract][Full Text] [Related]
31. FPGA Electronics for OPET: A Dual-Modality Optical and Positron Emission Tomograph. Douraghy A; Rannou FR; Silverman RW; Chatziioannou AF IEEE Trans Nucl Sci; 2008 Oct; 55(5):2541-2545. PubMed ID: 25722497 [TBL] [Abstract][Full Text] [Related]
32. Study of the resolution performance of an array of discrete detectors with independent readouts for positron emission tomography. Lecomte R; Martel C; Cadorette J IEEE Trans Med Imaging; 1991; 10(3):347-57. PubMed ID: 18222836 [TBL] [Abstract][Full Text] [Related]
33. Architecture and Implementation of OpenPET Firmware and Embedded Software. Abu-Nimeh FT; Ito J; Moses WW; Peng Q; Choong WS IEEE Trans Nucl Sci; 2016 Apr; 63(2):620-629. PubMed ID: 27110034 [TBL] [Abstract][Full Text] [Related]
34. An evaluation of a two-dimensional array detector for high resolution PET. Dahlbom M; Hoffman EJ IEEE Trans Med Imaging; 1988; 7(4):264-72. PubMed ID: 18230478 [TBL] [Abstract][Full Text] [Related]
35. Performance of positron imaging systems as a function of energy threshold and shielding depth. Mankoff D; Muehllehner G IEEE Trans Med Imaging; 1984; 3(1):18-24. PubMed ID: 18234606 [TBL] [Abstract][Full Text] [Related]
36. Note: design and construction of a multi-scale, high-resolution, tube-generated x-ray computed-tomography system for three-dimensional (3D) imaging. Mertens JC; Williams JJ; Chawla N Rev Sci Instrum; 2014 Jan; 85(1):016103. PubMed ID: 24517828 [TBL] [Abstract][Full Text] [Related]
37. Quad-Detector Arrangement and Sampling Characteristics in Rotary Positron Tomography: POSITOLOGICA II. Yamamoto M; Kawaguchi F IEEE Trans Med Imaging; 1982; 1(2):136-42. PubMed ID: 18238266 [TBL] [Abstract][Full Text] [Related]
38. A high resolution PET for animal studies. Watanabe M; Uchida H; Okada H; Shimizu K; Satoh N; Yoshikawa E; Ohmura T; Yamashita T; Tanaka E IEEE Trans Med Imaging; 1992; 11(4):577-80. PubMed ID: 18222900 [TBL] [Abstract][Full Text] [Related]
39. Digital pulse processing and optimization of the front-end electronics for nuclear instrumentation. Bobin C; Bouchard J; Thiam C; Ménesguen Y Appl Radiat Isot; 2014 May; 87():195-9. PubMed ID: 24326314 [TBL] [Abstract][Full Text] [Related]
40. Electrical substitution radiometry with feedback control: optimization of measurement time and resolution for repeated observations. Clare JF; White DR Appl Opt; 1992 Jun; 31(16):3123-30. PubMed ID: 20725257 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]