These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 18218653)

  • 1. Evaluation of biological aortic valve prostheses by dual source computer tomography and anatomic measurements for potential transapical valve-in-valve procedure.
    Grünenfelder J; Plass A; Alkadhi H; Genoni M
    Interact Cardiovasc Thorac Surg; 2008 Apr; 7(2):195-9; discussion 199-200. PubMed ID: 18218653
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Truly stentless autologous pericardial aortic valve replacement: an alternative to standard aortic valve replacement.
    Chan KM; Rahman-Haley S; Mittal TK; Gavino JA; Dreyfus GD
    J Thorac Cardiovasc Surg; 2011 Jan; 141(1):276-83. PubMed ID: 20965520
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Medium to long-term clinical outcome following stentless aortic valve replacement: comparison between allograft and xenograft valves.
    Ali A; Patel A; Ali Z; Abu-Omar Y; Freed D; Saeed A; Athanasiou T; Pepper J
    Interact Cardiovasc Thorac Surg; 2010 Aug; 11(2):166-70. PubMed ID: 20357012
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stability of aortic annulus enlargement during aortic valve replacement using a bovine pericardial patch: an 18-year clinical, echocardiographic, and angio-computed tomographic follow-up.
    Celiento M; Saccocci M; De Martino A; Nardi C; Faggioni L; Milano AD; Bortolotti U
    J Thorac Cardiovasc Surg; 2014 Mar; 147(3):977-83. PubMed ID: 23540656
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Morphologic findings in explanted Hancock II porcine bioprostheses.
    Butany J; Yu W; Silver MD; David TE
    J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sutureless aortic valve replacement: catheter-based transapical versus direct transaortic implantation.
    Doss M; Buhr E; Moritz A; Martens S
    J Heart Valve Dis; 2012 Nov; 21(6):758-63. PubMed ID: 23409358
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sutureless aortic valve prosthesis in a calcified homograft.
    Capestro F; Massaccesi S; Matteucci ML; Torracca L
    J Thorac Cardiovasc Surg; 2015 Sep; 150(3):e29-30. PubMed ID: 25963438
    [No Abstract]   [Full Text] [Related]  

  • 8. Aortic valve replacement with the Cryolife-O'Brien stentless aortic bioprosthesis: five-year experience.
    Martinovic I; Farah I; Everlien M; Knez I; Greve HP; Vogt P
    J Cardiovasc Surg (Torino); 2004 Dec; 45(6):557-63. PubMed ID: 15746635
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis.
    Mykén PS; Berggren HE; Larsson S; Roberts B; Wallentin I; Caidahl K
    J Thorac Cardiovasc Surg; 1998 Oct; 116(4):599-608. PubMed ID: 9766588
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Apico-aortic valved conduit as an alternative for aortic valve re-replacement in severe prosthesis-patient mismatch.
    Chahine JH; El-Rassi I; Jebara V
    Interact Cardiovasc Thorac Surg; 2009 Oct; 9(4):680-2. PubMed ID: 19643802
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inflammation and infection in nine surgically explanted Medtronic Freestyle stentless aortic valves.
    Butany J; Zhou T; Leong SW; Cunningham KS; Thangaroopan M; Jegatheeswaran A; Feindel C; David TE
    Cardiovasc Pathol; 2007; 16(5):258-67. PubMed ID: 17868876
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves.
    Eggebrecht H; Schäfer U; Treede H; Boekstegers P; Babin-Ebell J; Ferrari M; Möllmann H; Baumgartner H; Carrel T; Kahlert P; Lange P; Walther T; Erbel R; Mehta RH; Thielmann M
    JACC Cardiovasc Interv; 2011 Nov; 4(11):1218-27. PubMed ID: 22115663
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results.
    Bapat V; Attia R; Redwood S; Hancock J; Wilson K; Young C; Thomas M
    J Thorac Cardiovasc Surg; 2012 Dec; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Aortic Annulus Dimension After Aortic Valve Neocuspidization With Valve Replacement and Normal Valve.
    Yamamoto Y; Iino K; Shintani Y; Kato H; Kimura K; Watanabe G; Takemura H
    Semin Thorac Cardiovasc Surg; 2017 Summer; 29(2):143-149. PubMed ID: 28823320
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sutureless Perceval aortic valve in comparison with the stented Carpentier-Edwards Perimount aortic valve.
    König KC; Wahlers T; Scherner M; Wippermann J
    J Heart Valve Dis; 2014 Mar; 23(2):253-8. PubMed ID: 25076560
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Do statins slow the process of calcification of aortic tissue valves?
    Gilmanov D; Bevilacqua S; Mazzone A; Glauber M
    Interact Cardiovasc Thorac Surg; 2010 Sep; 11(3):297-301. PubMed ID: 20570976
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stented within a stentless aortic valve. A simple surgical solution for the replacement of a stentless aortic bioprosthesis.
    Panagiotou M; Kogerakis N; Crockett JR; Economidou S
    Interact Cardiovasc Thorac Surg; 2010 Jan; 10(1):7-8. PubMed ID: 19805504
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of bovine pericardial tissue for aortic valve and aortic root replacement: long-term results.
    Vrandecic M; Gontijo Filho B; Fantini F; Barbosa J; Martins I; de Oliveira OC; Martins C; Max R; Drumond L; Oliveira C; Ferrufino A; Alcocer E; Silva JA; Vrandecic E
    J Heart Valve Dis; 1998 Mar; 7(2):195-201. PubMed ID: 9587861
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anticalcification strategies to increase bioprosthetic valve durability.
    Thiene G; Valente M
    J Heart Valve Dis; 2011 Jan; 20(1):37-44. PubMed ID: 21404896
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mid-term results of aortic root replacement using a self-assembled biological composite graft.
    Meszaros K; Liniger S; Czerny M; Stanger O; Reineke D; Englberger L; Carrel TP
    Interact Cardiovasc Thorac Surg; 2014 Oct; 19(4):584-9. PubMed ID: 24994702
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.