283 related articles for article (PubMed ID: 18219694)
1. Review of optimal characteristics of face-masks for valved-holding chambers (VHCs).
Amirav I; Newhouse MT
Pediatr Pulmonol; 2008 Mar; 43(3):268-74. PubMed ID: 18219694
[TBL] [Abstract][Full Text] [Related]
2. Dead space variability of face masks for valved holding chambers.
Amirav I; Newhouse MT
Isr Med Assoc J; 2008 Mar; 10(3):224-6. PubMed ID: 18494237
[TBL] [Abstract][Full Text] [Related]
3. Design of facemasks for delivery of aerosol-based medication via pressurized metered dose inhaler with valved holding chamber: key issues that affect performance.
Morton RW; Mitchell JP
J Aerosol Med; 2007; 20 Suppl 1():S29-42; discussion S42-5. PubMed ID: 17411403
[TBL] [Abstract][Full Text] [Related]
4. Force-dependent static dead space of face masks used with holding chambers.
Shah SA; Berlinski AB; Rubin BK
Respir Care; 2006 Feb; 51(2):140-4. PubMed ID: 16441958
[TBL] [Abstract][Full Text] [Related]
5. Facemasks and aerosol delivery by metered dose inhaler-valved holding chamber in young children: a tight seal makes the difference.
Janssens HM; Tiddens HA
J Aerosol Med; 2007; 20 Suppl 1():S59-63; discussion S63-5. PubMed ID: 17411407
[TBL] [Abstract][Full Text] [Related]
6. Aerosol therapy with valved holding chambers in young children: importance of the facemask seal.
Amirav I; Newhouse MT
Pediatrics; 2001 Aug; 108(2):389-94. PubMed ID: 11483804
[TBL] [Abstract][Full Text] [Related]
7. Optimal administration of bronchodilators with valved holding chambers in preschool children: a review of literature.
Csonka P; Tapiainen T; Mäkelä MJ; Lehtimäki L
Eur J Pediatr; 2021 Oct; 180(10):3101-3109. PubMed ID: 33877400
[TBL] [Abstract][Full Text] [Related]
8. A novel, versatile valved holding chamber for delivering inhaled medications to neonates and small children: laboratory simulation of delivery options.
DiBlasi RM; Coppolo DP; Nagel MW; Doyle CC; Avvakoumova VI; Ali RS; Mitchell JP
Respir Care; 2010 Apr; 55(4):419-26. PubMed ID: 20406509
[TBL] [Abstract][Full Text] [Related]
9. Methodology for the in vitro evaluation of the delivery efficiency from valved holding chambers with facemasks.
Xu Z; Hsu W; von Hollen D; Viswanath A; Nikander K; Dalby R
J Aerosol Med Pulm Drug Deliv; 2014 Aug; 27 Suppl 1():S44-54. PubMed ID: 24219816
[TBL] [Abstract][Full Text] [Related]
10. An instrumented valved holding chamber with facemask to measure application forces and flow in young asthmatic children.
Minh KT; von Hollen D; von Königslöw AJ; Nikander K; Janssens HM
J Aerosol Med Pulm Drug Deliv; 2014 Aug; 27 Suppl 1():S55-62. PubMed ID: 25054482
[TBL] [Abstract][Full Text] [Related]
11. Effect of face mask dead volume, respiratory rate, and tidal volume on inhaled albuterol delivery.
Chavez A; McCracken A; Berlinski A
Pediatr Pulmonol; 2010 Mar; 45(3):224-9. PubMed ID: 20146371
[TBL] [Abstract][Full Text] [Related]
12. Comparative in vitro performance of three small-volume valved holding chambers with beclomethasone/formoterol pressurized metered dose inhaler.
Goncalves TM; Alhanout K; Nicolay A; Dubus JC; de Santana DP; Andrieu V
J Aerosol Med Pulm Drug Deliv; 2013 Aug; 26(4):223-7. PubMed ID: 23094686
[TBL] [Abstract][Full Text] [Related]
13. Effect of facial material softness and applied force on face mask dead volume, face mask seal, and inhaled corticosteroid delivery through an idealized infant replica.
Carrigy NB; O'Reilly C; Schmitt J; Noga M; Finlay WH
J Aerosol Med Pulm Drug Deliv; 2014 Aug; 27(4):290-8. PubMed ID: 24219815
[TBL] [Abstract][Full Text] [Related]
14. Redesigned face mask improves "real life" aerosol delivery for Nebuchamber.
Amirav I; Mansour Y; Mandelberg A; Bar-Ilan I; Newhouse MT
Pediatr Pulmonol; 2004 Feb; 37(2):172-7. PubMed ID: 14730663
[TBL] [Abstract][Full Text] [Related]
15. Variation in pediatric aerosol delivery: importance of facemask.
Smaldone GC; Berg E; Nikander K
J Aerosol Med; 2005; 18(3):354-63. PubMed ID: 16181009
[TBL] [Abstract][Full Text] [Related]
16. Mask Use with Spacers/Valved Holding Chambers and Metered Dose Inhalers among Children with Asthma.
Volerman A; Balachandran U; Siros M; Akel M; Press VG
Ann Am Thorac Soc; 2021 Jan; 18(1):17-22. PubMed ID: 33052700
[TBL] [Abstract][Full Text] [Related]
17. The conversion to metered-dose inhaler with valved holding chamber to administer inhaled albuterol: a pediatric hospital experience.
Salyer JW; DiBlasi RM; Crotwell DN; Cowan CA; Carter ER
Respir Care; 2008 Mar; 53(3):338-45. PubMed ID: 18291050
[TBL] [Abstract][Full Text] [Related]
18. Considerations for Designing In Vitro Bioequivalence (IVBE) Studies for Pressurized Metered Dose Inhalers (pMDIs) with Spacer or Valved Holding Chamber (S/VHC) Add-on Devices.
Sandell D; Mitchell JP
J Aerosol Med Pulm Drug Deliv; 2015 Jun; 28(3):156-81. PubMed ID: 25089555
[TBL] [Abstract][Full Text] [Related]
19. Clinically relevant test methods to establish in vitro equivalence for spacers and valved holding chambers used with pressurized metered dose inhalers (pMDIs).
Mitchell J; Dolovich MB
J Aerosol Med Pulm Drug Deliv; 2012 Aug; 25(4):217-42. PubMed ID: 22857273
[TBL] [Abstract][Full Text] [Related]
20. Jet nebulizers versus pressurized metered dose inhalers with valved holding chambers: effects of the facemask on aerosol delivery.
Nikander K; Berg E; Smaldone GC
J Aerosol Med; 2007; 20 Suppl 1():S46-55; discussion S55-8. PubMed ID: 17411405
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]