BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

291 related articles for article (PubMed ID: 18222800)

  • 1. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging].
    Pauly J; Le Roux P; Nishimura D; Macovski A
    IEEE Trans Med Imaging; 1991; 10(1):53-65. PubMed ID: 18222800
    [TBL] [Abstract][Full Text] [Related]  

  • 2. General parameter relations for the Shinnar-Le Roux pulse design algorithm.
    Lee KJ
    J Magn Reson; 2007 Jun; 186(2):252-8. PubMed ID: 17408999
    [TBL] [Abstract][Full Text] [Related]  

  • 3. |B1(+)|-selective excitation pulse design using the Shinnar-Le Roux algorithm.
    Grissom WA; Cao Z; Does MD
    J Magn Reson; 2014 May; 242():189-96. PubMed ID: 24674887
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Combined simulated annealing and Shinnar-Le Roux pulse design of slice-multiplexed RF pulses for multi-slice imaging.
    Lee KJ; Paley MN; Wild JM
    J Magn Reson; 2006 Sep; 182(1):133-42. PubMed ID: 16828567
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Generalized Estimate of the SLR B Polynomial Ripples for RF Pulse Generation.
    Raddi A; Klose U
    J Magn Reson; 1998 Jun; 132(2):260-5. PubMed ID: 9632551
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.
    Balchandani P; Qiu D
    Magn Reson Imaging; 2014 Sep; 32(7):804-12. PubMed ID: 24928300
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method.
    Grissom WA; McKinnon GC; Vogel MW
    Magn Reson Med; 2012 Sep; 68(3):690-702. PubMed ID: 22161690
    [TBL] [Abstract][Full Text] [Related]  

  • 8. SLfRank: Shinnar-Le-Roux Pulse Design With Reduced Energy and Accurate Phase Profiles Using Rank Factorization.
    Ong F; Zhong Z; Liao C; Lustig M; Vasanawala SS; Pauly JM
    IEEE Trans Med Imaging; 2023 May; 42(5):1522-1531. PubMed ID: 37015710
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficient design of pulses with trapezoidal magnitude and linear phase response profiles.
    Pickup S; Popescu M
    Magn Reson Med; 1997 Jul; 38(1):137-45. PubMed ID: 9211389
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimized Shinnar-Le Roux RF 180 degrees pulses in fast spin-echo measurements.
    Raddi A; Klose U
    J Magn Reson Imaging; 1999 Apr; 9(4):613-20. PubMed ID: 10232522
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Robust slice-selective broadband refocusing pulses.
    Janich MA; Schulte RF; Schwaiger M; Glaser SJ
    J Magn Reson; 2011 Dec; 213(1):126-35. PubMed ID: 21974997
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selective maximization of (31)P MR spectroscopic signals of in vivo human brain metabolites at 3T.
    Blenman RA; Port JD; Felmlee JP
    J Magn Reson Imaging; 2007 Mar; 25(3):628-34. PubMed ID: 17279535
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Practical pulse synthesis via the discrete inverse scattering transform.
    Magland J; Epstein CL
    J Magn Reson; 2005 Jan; 172(1):63-78. PubMed ID: 15589409
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improved Shinnar-Le Roux algorithm.
    Ikonomidou VN; Sergiadis GD
    J Magn Reson; 2000 Mar; 143(1):30-4. PubMed ID: 10698643
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Velocity sensitivity of slice-selective excitation.
    Lewis DP; Tsui BM; Moran PR
    Magn Reson Imaging; 1998 Oct; 16(8):907-16. PubMed ID: 9814773
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Deep Reinforcement Learning Designed Shinnar-Le Roux RF Pulse Using Root-Flipping: DeepRF
    Shin D; Ji S; Lee D; Lee J; Oh SH; Lee J
    IEEE Trans Med Imaging; 2020 Dec; 39(12):4391-4400. PubMed ID: 32833629
    [TBL] [Abstract][Full Text] [Related]  

  • 17. T2-selective magnetization preparation pulses.
    Vidarsson L; Cunningham C; Gold GE; Pauly JM
    IEEE Trans Med Imaging; 2007 Jul; 26(7):981-9. PubMed ID: 17649911
    [TBL] [Abstract][Full Text] [Related]  

  • 18. RE Pulse Shapes for Selective Excitation in NMR Imaging.
    Smith MR
    IEEE Trans Med Imaging; 1985; 4(2):79-83. PubMed ID: 18243955
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chebyshev series for designing RF pulses employing an optimal control approach.
    Ulloa JL; Guarini M; Guesalaga A; Irarrazaval P
    IEEE Trans Med Imaging; 2004 Nov; 23(11):1445-52. PubMed ID: 15554131
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of broadband RF pulses with polynomial-phase response.
    Schulte RF; Henning A; Tsao J; Boesiger P; Pruessmann KP
    J Magn Reson; 2007 Jun; 186(2):167-75. PubMed ID: 17331765
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.