372 related articles for article (PubMed ID: 18224357)
1. Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.
Koller H; Acosta F; Tauber M; Fox M; Martin H; Forstner R; Augat P; Penzkofer R; Pirich C; Kässmann H; Resch H; Hitzl W
Eur Spine J; 2008 Apr; 17(4):539-55. PubMed ID: 18224357
[TBL] [Abstract][Full Text] [Related]
2. In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III).
Koller H; Hitzl W; Acosta F; Tauber M; Zenner J; Resch H; Yukawa Y; Meier O; Schmidt R; Mayer M
Eur Spine J; 2009 Sep; 18(9):1300-13. PubMed ID: 19575244
[TBL] [Abstract][Full Text] [Related]
3. Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.
Koller H; Hempfing A; Acosta F; Fox M; Scheiter A; Tauber M; Holz U; Resch H; Hitzl W
Eur Spine J; 2008 Apr; 17(4):523-38. PubMed ID: 18224358
[TBL] [Abstract][Full Text] [Related]
4. Anterior transpedicular screw fixation of cervical spine: Is it safe? Morphological feasibility, technical properties, and accuracy of manual insertion.
Koktekir E; Toktas ZO; Seker A; Akakin A; Konya D; Kilic T
J Neurosurg Spine; 2015 Jun; 22(6):596-604. PubMed ID: 25815805
[TBL] [Abstract][Full Text] [Related]
5. Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques.
Ludwig SC; Kramer DL; Balderston RA; Vaccaro AR; Foley KF; Albert TJ
Spine (Phila Pa 1976); 2000 Jul; 25(13):1655-67. PubMed ID: 10870141
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws.
Patton AG; Morris RP; Kuo YF; Lindsey RW
Spine (Phila Pa 1976); 2015 Apr; 40(7):E404-10. PubMed ID: 25599290
[TBL] [Abstract][Full Text] [Related]
7. Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.
Reinhold M; Magerl F; Rieger M; Blauth M
Eur Spine J; 2007 Jan; 16(1):47-56. PubMed ID: 16628443
[TBL] [Abstract][Full Text] [Related]
8. The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping.
Koller H; Schmidt R; Mayer M; Hitzl W; Zenner J; Midderhoff S; Graf N; Resch H; Wilke HJ
Eur Spine J; 2010 Dec; 19(12):2137-48. PubMed ID: 20589516
[TBL] [Abstract][Full Text] [Related]
9. Paravertebral foramen screw fixation for posterior cervical spine fusion: biomechanical study and description of a novel technique.
Maki S; Aramomi M; Matsuura Y; Furuya T; Ota M; Iijima Y; Saito J; Suzuki T; Mannoji C; Takahashi K; Yamazaki M; Koda M
J Neurosurg Spine; 2017 Oct; 27(4):415-420. PubMed ID: 28498072
[TBL] [Abstract][Full Text] [Related]
10. [Comparison of statics characteristics between anterior transpedicular screws system and vertebral body screws system in lower cervical spine].
Zhao LJ; Li J; Jiang WY; Xu RM; Ma WH; Qi F; Yu L; Zhang M; Wang YJ
Zhongguo Gu Shang; 2014 Feb; 27(2):118-22. PubMed ID: 24826474
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical analysis of differential pull-out strengths of bone screws using cervical anterior transpedicular technique in normal and osteoporotic cervical cadaveric spines.
Wu C; Chen C; Wu W; Zhao W; Sun P; Fan J; Bi Z; Zhang J; Ouyang J
Spine (Phila Pa 1976); 2015 Jan; 40(1):E1-8. PubMed ID: 25341974
[TBL] [Abstract][Full Text] [Related]
12. Posterior cervicothoracic instrumentation in spine tumors.
Mazel C; Hoffmann E; Antonietti P; Grunenwald D; Henry M; Williams J
Spine (Phila Pa 1976); 2004 Jun; 29(11):1246-53. PubMed ID: 15167665
[TBL] [Abstract][Full Text] [Related]
13. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.
Kawaguchi Y; Nakano M; Yasuda T; Seki S; Hori T; Kimura T
Spine (Phila Pa 1976); 2012 Nov; 37(23):1983-8. PubMed ID: 22531473
[TBL] [Abstract][Full Text] [Related]
14. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study.
Luo J; Wu C; Huang Z; Pan Z; Li Z; Zhong J; Chen Y; Han Z; Cao K
Arch Orthop Trauma Surg; 2017 Apr; 137(4):517-522. PubMed ID: 28236185
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical evaluation of a novel anterior transpedicular screw-plate system for anterior cervical corpectomy and fusion (ACCF): a finite element analysis.
Huang S; Ling Q; Lin X; Qin H; Luo X; Huang W
Front Bioeng Biotechnol; 2023; 11():1260204. PubMed ID: 38026869
[No Abstract] [Full Text] [Related]
16. Which salvage fixation technique is best for the failed initial screw fixation at the cervicothoracic junction? A biomechanical comparison study.
Hong JT; Tomoyuki T; Jain A; Orías AAE; Inoue N; An HS
Eur Spine J; 2017 Sep; 26(9):2417-2424. PubMed ID: 28752245
[TBL] [Abstract][Full Text] [Related]
17. Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study.
Bredow J; Meyer C; Scheyerer MJ; Siedek F; Müller LP; Eysel P; Stein G
Eur Spine J; 2016 Jun; 25(6):1683-9. PubMed ID: 26810977
[TBL] [Abstract][Full Text] [Related]
18. The medial cortical pedicle screw--a new technique for cervical pedicle screw placement with partial drilling of medial cortex.
Mahesh B; Upendra B; Mahan RS
Spine J; 2014 Feb; 14(2):371-80. PubMed ID: 24444420
[TBL] [Abstract][Full Text] [Related]
19. Cervical pedicle screws: comparative accuracy of two insertion techniques.
Ludwig SC; Kowalski JM; Edwards CC; Heller JG
Spine (Phila Pa 1976); 2000 Oct; 25(20):2675-81. PubMed ID: 11034656
[TBL] [Abstract][Full Text] [Related]
20. Construction and accuracy assessment of patient-specific biocompatible drill template for cervical anterior transpedicular screw (ATPS) insertion: an in vitro study.
Fu M; Lin L; Kong X; Zhao W; Tang L; Li J; Ouyang J
PLoS One; 2013; 8(1):e53580. PubMed ID: 23326461
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]