160 related articles for article (PubMed ID: 18232378)
1. On the a priori identifiability of the two-compartment distributed parameter model from residual tracer data acquired by dynamic contrast-enhanced imaging.
Koh TS
IEEE Trans Biomed Eng; 2008 Jan; 55(1):340-4. PubMed ID: 18232378
[TBL] [Abstract][Full Text] [Related]
2. Tracer kinetics analysis of dynamic contrast-enhanced CT and MR data in patients with squamous cell carcinoma of the upper aerodigestive tract: comparison of the results.
Bisdas S; Baghi M; Wagenblast J; Bisdas T; Thng CH; Mack MG; Koh TS; Ernemann U
Clin Physiol Funct Imaging; 2009 Sep; 29(5):339-46. PubMed ID: 19473200
[TBL] [Abstract][Full Text] [Related]
3. Tracer kinetic analysis of signal time series from dynamic contrast-enhanced MR imaging.
Brix G; Lucht R; Griebel J
Biomed Tech (Berl); 2006 Dec; 51(5-6):325-30. PubMed ID: 17155868
[TBL] [Abstract][Full Text] [Related]
4. Reproducibility of the aortic input function (AIF) derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the kidneys in a volunteer study.
Mendichovszky IA; Cutajar M; Gordon I
Eur J Radiol; 2009 Sep; 71(3):576-81. PubMed ID: 19004588
[TBL] [Abstract][Full Text] [Related]
5. Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI.
Cheng HL
J Magn Reson Imaging; 2008 Sep; 28(3):736-43. PubMed ID: 18777534
[TBL] [Abstract][Full Text] [Related]
6. Quantitative analysis of dynamic contrast enhanced MRI for assessment of bowel inflammation in Crohn's disease pilot study.
Oto A; Fan X; Mustafi D; Jansen SA; Karczmar GS; Rubin DT; Kayhan A
Acad Radiol; 2009 Oct; 16(10):1223-30. PubMed ID: 19524458
[TBL] [Abstract][Full Text] [Related]
7. Improved bolus arrival time and arterial input function estimation for tracer kinetic analysis in DCE-MRI.
Singh A; Rathore RK; Haris M; Verma SK; Husain N; Gupta RK
J Magn Reson Imaging; 2009 Jan; 29(1):166-76. PubMed ID: 19097111
[TBL] [Abstract][Full Text] [Related]
8. Dynamic contrast-enhanced CT of head and neck tumors: perfusion measurements using a distributed-parameter tracer kinetic model. Initial results and comparison with deconvolution-based analysis.
Bisdas S; Konstantinou GN; Lee PS; Thng CH; Wagenblast J; Baghi M; Koh TS
Phys Med Biol; 2007 Oct; 52(20):6181-96. PubMed ID: 17921579
[TBL] [Abstract][Full Text] [Related]
9. A method for pharmacokinetic modelling of dynamic contrast enhanced MRI studies of rapidly enhancing lesions acquired in a clinical setting.
Radjenovic A; Ridgway JP; Smith MA
Phys Med Biol; 2006 May; 51(9):N187-97. PubMed ID: 16625029
[TBL] [Abstract][Full Text] [Related]
10. Perfusion parameters derived from bolus-tracking perfusion imaging are immune to tracer recirculation.
Kosior JC; Frayne R
J Magn Reson Imaging; 2010 Mar; 31(3):753-6. PubMed ID: 20187222
[TBL] [Abstract][Full Text] [Related]
11. Effects of water exchange on MRI-based determination of relative blood volume using an inversion-prepared gradient echo sequence and a blood pool contrast medium.
Carreira GC; Gemeinhardt O; Beyersdorff D; Schnorr J; Taupitz M; Lüdemann L
Magn Reson Imaging; 2009 Apr; 27(3):360-9. PubMed ID: 18768279
[TBL] [Abstract][Full Text] [Related]
12. Analysis of prostate DCE-MRI: comparison of fast exchange limit and fast exchange regimen pharmacokinetic models in the discrimination of malignant from normal tissue.
Lowry M; Zelhof B; Liney GP; Gibbs P; Pickles MD; Turnbull LW
Invest Radiol; 2009 Sep; 44(9):577-84. PubMed ID: 19668002
[TBL] [Abstract][Full Text] [Related]
13. Scan-rescan variability in perfusion assessment of tumors in MRI using both model and data-derived arterial input functions.
Ashton E; Raunig D; Ng C; Kelcz F; McShane T; Evelhoch J
J Magn Reson Imaging; 2008 Sep; 28(3):791-6. PubMed ID: 18777526
[TBL] [Abstract][Full Text] [Related]
14. Gadolinium-enhanced echo-planar T2-weighted MRI of tumors in the extracranial head and neck: feasibility study and preliminary results using a distributed-parameter tracer kinetic analysis.
Bisdas S; Baghi M; Wagenblast J; Vogl TJ; Thng CH; Koh TS
J Magn Reson Imaging; 2008 May; 27(5):963-9. PubMed ID: 18407543
[TBL] [Abstract][Full Text] [Related]
15. The use of the Levenberg-Marquardt curve-fitting algorithm in pharmacokinetic modelling of DCE-MRI data.
Ahearn TS; Staff RT; Redpath TW; Semple SI
Phys Med Biol; 2005 May; 50(9):N85-92. PubMed ID: 15843726
[TBL] [Abstract][Full Text] [Related]
16. A physiologic model of capillary-tissue exchange for dynamic contrast-enhanced imaging of tumor microcirculation.
Koh TS; Cheong LH; Hou Z; Soh YC
IEEE Trans Biomed Eng; 2003 Feb; 50(2):159-67. PubMed ID: 12665029
[TBL] [Abstract][Full Text] [Related]
17. Determination of pharmacokinetic parameters in DCE MRI: Consequence of nonlinearity between contrast agent concentration and signal intensity.
Heilmann M; Kiessling F; Enderlin M; Schad LR
Invest Radiol; 2006 Jun; 41(6):536-43. PubMed ID: 16763473
[TBL] [Abstract][Full Text] [Related]
18. Interpretation and applicability of empirical tissue enhancement metrics in dynamic contrast-enhanced MRI based on a multiple pathway model.
Koh TS; Shi W; Thng CH; Kwek JW; Bisdas S; Khoo JB
Phys Med Biol; 2012 Aug; 57(15):N279-94. PubMed ID: 22796722
[TBL] [Abstract][Full Text] [Related]
19. A distributed parameter model of cerebral blood-tissue exchange with account of capillary transit time distribution.
Koh TS; Cheong LH; Tan CK; Lim CC
Neuroimage; 2006 Apr; 30(2):426-35. PubMed ID: 16246589
[TBL] [Abstract][Full Text] [Related]
20. The precision of pharmacokinetic parameters in dynamic contrast-enhanced magnetic resonance imaging: the effect of sampling frequency and duration.
Aerts HJ; Jaspers K; Backes WH
Phys Med Biol; 2011 Sep; 56(17):5665-78. PubMed ID: 21828909
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]