These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 18238430)

  • 1. Line-focusing electromagnetic acoustic transducers for the detection of slit defects.
    Ogi H; Hirao M; Ohtani T
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(2):341-6. PubMed ID: 18238430
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical and experimental analysis of unidirectional meander-line coil electromagnetic acoustic transducers.
    Wang S; Su R; Chen X; Kang L; Zhai G
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Dec; 60(12):2657-64. PubMed ID: 24297030
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wideband low frequency generation and detection of Lamb and Rayleigh waves using electromagnetic acoustic transducers (EMATs).
    Dixon S; Palmer SB
    Ultrasonics; 2004 Aug; 42(10):1129-36. PubMed ID: 15234175
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimization of a Focusable and Rotatable Shear-Wave Periodic Permanent Magnet Electromagnetic Acoustic Transducers for Plates Inspection.
    Song X; Qiu G
    Sensors (Basel); 2017 Nov; 17(12):. PubMed ID: 29186790
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Coupling mechanism of an EMAT.
    Jian X; Dixon S; Edwards RS; Morrison J
    Ultrasonics; 2006 Dec; 44 Suppl 1():e653-6. PubMed ID: 16793101
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A New Electromagnetic Acoustic Transducer Design for Generating and Receiving S0 Lamb Waves in Ferromagnetic Steel Plate.
    He J; Dixon S; Hill S; Xu K
    Sensors (Basel); 2017 May; 17(5):. PubMed ID: 28471377
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New Combination of Magnet and Coil of Electromagnetic Acoustic Transducer for Generating and Detecting Rayleigh Wave.
    Sun H; Uchimoto T; Takagi T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Apr; 67(4):832-839. PubMed ID: 31796394
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new chevron electromagnetic acoustic transducer design for generating shear horizontal guided wave.
    Gautam AK; Yin CC; Bhattacharya B
    Ultrasonics; 2023 Dec; 135():107137. PubMed ID: 37634477
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A study of internal defect testing with the laser-EMAT ultrasonic method.
    Pei C; Fukuchi T; Zhu H; Koyama K; Demachi K; Uesaka M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Dec; 59(12):2702-8. PubMed ID: 23221219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Generation and detection of higher-order mode clusters of guided waves (HOMC-GW) using meander-coil EMATs.
    Ratnam D; Balasubramaniam K; Maxfield BW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Apr; 59(4):727-37. PubMed ID: 22547283
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Study and comparison of different EMAT configurations for SH wave inspection.
    Ribichini R; Cegla F; Nagy PB; Cawley P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Dec; 58(12):2571-81. PubMed ID: 23443693
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Internal and External Pipe Defect Characterization via High-Frequency Lamb Waves Generated by Unidirectional EMAT.
    Zhang X; Li B; Zhang X; Song X; Tu J; Cai C; Yuan J; Wu Q
    Sensors (Basel); 2023 Oct; 23(21):. PubMed ID: 37960540
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Depth gauging of defects using low frequency wideband Rayleigh waves.
    Edwards RS; Dixon S; Jian X
    Ultrasonics; 2006 Jan; 44(1):93-8. PubMed ID: 16246389
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Unidirectional Shear Horizontal Wave Generation With Side-Shifted Periodic Permanent Magnets Electromagnetic Acoustic Transducer.
    Kubrusly AC; Kang L; Dixon S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Dec; 67(12):2757-2760. PubMed ID: 32986551
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Lift-off compensation for improved accuracy in ultrasonic lamb wave velocity measurements using electromagnetic acoustic transducers (EMATs).
    Morrison JP; Dixon S; Potter MD; Jian X
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1401-4. PubMed ID: 16828139
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Oblique Point-Focusing Shear-Horizontal Guided-Wave Electromagnetic Acoustic Transducer With Variable PPM Spacing.
    Sun H; Wang S; Huang S; Peng L; Wang Q; Zhao W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Aug; 67(8):1691-1700. PubMed ID: 32175860
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of Magnetostriction Induced by the Periodic Permanent Magnet Electromagnetic Acoustic Transducer (PPM EMAT) on Steel.
    Sun CZ; Sinclair A; Filleter T
    Sensors (Basel); 2021 Nov; 21(22):. PubMed ID: 34833773
    [TBL] [Abstract][Full Text] [Related]  

  • 18. EMAT phased array: A feasibility study of surface crack detection.
    Isla J; Cegla F
    Ultrasonics; 2017 Jul; 78():1-9. PubMed ID: 28268180
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Driving frequency dependent wave modes of point-focusing electromagnetic acoustic transducers.
    Jia X; Ouyang Q
    Rev Sci Instrum; 2018 Aug; 89(8):085006. PubMed ID: 30184677
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterizing excitability of Lamb waves generated by electromagnetic acoustic transducers with coupled frequency domain models.
    Wang S; Huang S; Wang Q; Wang Z; Zhao W
    Ultrasonics; 2019 Mar; 93():71-80. PubMed ID: 30445202
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.