These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 18238480)

  • 1. Echo decorrelation from displacement gradients in elasticity and velocity estimation.
    Cespedes EI; de Korte CL; van der Steen AW
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(4):791-801. PubMed ID: 18238480
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: applications to elastography.
    Alam SK; Ophir J
    Ultrasound Med Biol; 1997; 23(1):95-105. PubMed ID: 9080622
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The combined effect of signal decorrelation and random noise on the variance of time delay estimation.
    Cespedes I; Ophir J; Alam SK
    IEEE Trans Ultrason Ferroelectr Freq Control; 1997; 44(1):220-5. PubMed ID: 18244121
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A deconvolution filter for improvement of time-delay estimation in elastography.
    Alam SK; Ophir J; Cespedes I; Varghese T
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(6):1565-72. PubMed ID: 18250004
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Enhancement of echo-signal correlation in elastography using temporal stretching.
    Varghese T; Ophir J
    IEEE Trans Ultrason Ferroelectr Freq Control; 1997; 44(1):173-80. PubMed ID: 18244115
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An adaptive strain estimator for elastography.
    Alam SK; Ophir J; Konofagou EE
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(2):461-72. PubMed ID: 18244197
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation.
    Lubinski MA; Emelianov SY; O'Donnell M
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(1):82-96. PubMed ID: 18238401
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Decorrelation of intravascular echo signals: potentials for blood velocity estimation.
    Li W; Lancée CT; Céspedes EI; van der Steen AF; Bom N
    J Acoust Soc Am; 1997 Dec; 102(6):3785-94. PubMed ID: 9407670
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduction of echo decorrelation via complex principal component filtering.
    Mauldin FW; Viola F; Walker WF
    Ultrasound Med Biol; 2009 Aug; 35(8):1325-43. PubMed ID: 19520491
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Complex principal components for robust motion estimation.
    Mauldin FW; Viola F; Walker WF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Nov; 57(11):2437-49. PubMed ID: 21041131
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of tissue changes, measurement system effects, and motion artifacts in echo decorrelation imaging.
    Hooi FM; Nagle A; Subramanian S; Douglas Mast T
    J Acoust Soc Am; 2015 Feb; 137(2):585-97. PubMed ID: 25697993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimation and reduction of decorrelation effect due to tissue lateral displacement in elastography.
    Bai J; Ding C; Luo J; He P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 May; 49(5):541-9. PubMed ID: 12046929
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lateral blood flow velocity estimation based on ultrasound speckle size change with scan velocity.
    Xu T; Bashford GR
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Dec; 57(12):2695-703. PubMed ID: 21156365
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The combined effect of nonlinear filtration and window size on the accuracy of tissue displacement estimation using detected echo signals.
    Behar V; Adam D; Lysyansky P; Friedman Z
    Ultrasonics; 2004 Mar; 41(9):743-53. PubMed ID: 14996535
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Speckle decorrelation due to two-dimensional flow gradients.
    Friemel BH; Bohs LN; Nightingale KR; Trahey GE
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(2):317-27. PubMed ID: 18244183
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On velocity estimation using speckle decorrelation.
    Li PC; Cheng CJ; Yeh CK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2001 Jul; 48(4):1084-91. PubMed ID: 11477767
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Filter-based compounded delay estimation with application to strain imaging.
    Liu P; Liu D
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Oct; 58(10):2078-95. PubMed ID: 21989872
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance evaluation of methods for two-dimensional displacement and strain estimation using ultrasound radio frequency data.
    Lopata RG; Nillesen MM; Hansen HH; Gerrits IH; Thijssen JM; de Korte CL
    Ultrasound Med Biol; 2009 May; 35(5):796-812. PubMed ID: 19282094
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 2-D companding for noise reduction in strain imaging.
    Chaturvedi P; Insana MF; Hall TJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(1):179-91. PubMed ID: 18244170
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Frequency-domain-based strain estimation and high-frame-rate imaging for quasi-static elastography.
    Ramalli A; Basset O; Cachard C; Boni E; Tortoli P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Apr; 59(4):817-24. PubMed ID: 22547293
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.