These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 18240336)
1. Research on the axis shape of an active catheter. Fu Y; Li X; Wang S; Liu H; Liang Z Int J Med Robot; 2008 Mar; 4(1):69-76. PubMed ID: 18240336 [TBL] [Abstract][Full Text] [Related]
2. [Study on active catheter for minimally invasive surgery based on large deflection theory]. Wang S; Liu H; Fu Y; Li X Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):393-7. PubMed ID: 18610629 [TBL] [Abstract][Full Text] [Related]
3. An artificial muscle actuator for biomimetic underwater propulsors. Yim W; Lee J; Kim KJ Bioinspir Biomim; 2007 Jun; 2(2):S31-41. PubMed ID: 17671327 [TBL] [Abstract][Full Text] [Related]
4. [Methods of resolution for haptic assistance during catheterization]. Kern TA; Herrmann J; Klages S; Meiss T; Werthschützky R Biomed Tech (Berl); 2005; 50(1-2):8-13. PubMed ID: 15792195 [TBL] [Abstract][Full Text] [Related]
5. [Study on an actuation system for matrix control of the active catheter in a minimally-invasive intervention surgery]. Fu YL; Ma HH; Li XL Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Nov; 30(6):416-8, 430. PubMed ID: 17300007 [TBL] [Abstract][Full Text] [Related]
6. Numerical evaluation method for catheter prototypes using photo-elastic stress analysis on patient-specific vascular model. Tercero C; Okada Y; Ikeda S; Fukuda T; Sekiyama K; Negoro M; Takahashi I Int J Med Robot; 2007 Dec; 3(4):349-54. PubMed ID: 18200627 [TBL] [Abstract][Full Text] [Related]
7. A catheter side wall tactile sensor: design, modeling and experiments. Wang H; Liu PX; Guo S; Ye X Minim Invasive Ther Allied Technol; 2010; 19(1):52-60. PubMed ID: 20095899 [TBL] [Abstract][Full Text] [Related]
8. Effect of fiber shape on mechanical behavior of composite with elastoplastic matrix and SMA reinforcement. Zhu Y; Dui G J Mech Behav Biomed Mater; 2009 Oct; 2(5):454-9. PubMed ID: 19627851 [TBL] [Abstract][Full Text] [Related]
9. Non-linear finite element stress analysis of plastic deformation in Co-Cr wrought-wire clasps. Shirasu K; Wakabayashi N; Yoneyama T; Igarashi Y Dent Mater; 2008 Nov; 24(11):1518-24. PubMed ID: 18462786 [TBL] [Abstract][Full Text] [Related]
10. Microbore catheters: keys to successful design and manufacture, Part I. Kramer HW Med Device Technol; 2001 Oct; 12(8):14-6. PubMed ID: 12938543 [TBL] [Abstract][Full Text] [Related]
11. Types of urethral catheters for management of short-term voiding problems in hospitalized adults: a short version Cochrane review. Schumm K; Lam TB Neurourol Urodyn; 2008; 27(8):738-46. PubMed ID: 18951451 [TBL] [Abstract][Full Text] [Related]
12. Modelling and optimization of micro optofluidic lenses. Song C; Nguyen NT; Tan SH; Asundi AK Lab Chip; 2009 May; 9(9):1178-84. PubMed ID: 19370234 [TBL] [Abstract][Full Text] [Related]
13. Thermal and hydrodynamic modelling of active catheters for interventional radiology. Marchandise E; Flaud P; Royon L; Blanc R; Szewczyk J Comput Methods Biomech Biomed Engin; 2011 Jul; 14(7):595-602. PubMed ID: 21104481 [TBL] [Abstract][Full Text] [Related]
14. Nonlinear characteristics of a circular plate piezoelectric harvester with relatively large deflection near resonance. Xue H; Hu H IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Sep; 55(9):2092-6. PubMed ID: 18986906 [TBL] [Abstract][Full Text] [Related]
15. Transmitting electric energy through a closed elastic wall by acoustic waves and piezoelectric transducers. Yang Z; Guo S; Yang J IEEE Trans Ultrason Ferroelectr Freq Control; 2008; 55(6):1380-6. PubMed ID: 18599426 [TBL] [Abstract][Full Text] [Related]
16. Modeling friction, intrinsic curvature, and rotation of guide wires for simulation of minimally invasive vascular interventions. Alderliesten T; Konings MK; Niessen WJ IEEE Trans Biomed Eng; 2007 Jan; 54(1):29-38. PubMed ID: 17260853 [TBL] [Abstract][Full Text] [Related]
17. Design and preliminary in vivo validation of a robotic laparoscope holder for minimally invasive surgery. Herman B; Dehez B; Duy KT; Raucent B; Dombre E; Krut S Int J Med Robot; 2009 Sep; 5(3):319-26. PubMed ID: 19455594 [TBL] [Abstract][Full Text] [Related]
18. Three dimensional transient multifield analysis of a piezoelectric micropump for drug delivery system for treatment of hemodynamic dysfunctions. Nisar A; Afzulpurkar N; Tuantranont A; Mahaisavariya B Cardiovasc Eng; 2008 Dec; 8(4):203-18. PubMed ID: 19030990 [TBL] [Abstract][Full Text] [Related]
19. Bioinspired actuation of the eyeballs of an android robotic face: concept and preliminary investigations. Carpi F; De Rossi D Bioinspir Biomim; 2007 Jun; 2(2):S50-63. PubMed ID: 17671329 [TBL] [Abstract][Full Text] [Related]
20. Establishment of a biomimetic device based on tri-layer polymer actuators--propulsion fins. Alici G; Spinks G; Huynh NN; Sarmadi L; Minato R Bioinspir Biomim; 2007 Jun; 2(2):S18-30. PubMed ID: 17671326 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]