341 related articles for article (PubMed ID: 18243899)
1. Modern techniques for the diagnostic evaluation of the trephine bone marrow biopsy: methodological aspects and applications.
Fend F; Tzankov A; Bink K; Seidl S; Quintanilla-Martinez L; Kremer M; Dirnhofer S
Prog Histochem Cytochem; 2008; 42(4):203-52. PubMed ID: 18243899
[TBL] [Abstract][Full Text] [Related]
2. Fluorescence in situ hybridisation analysis of bone marrow trephine biopsy specimens; an additional tool in the diagnostic armoury.
Neat MJ; Moonim MT; Dunn RG; Geoghegan H; Foot NJ
J Clin Pathol; 2013 Jan; 66(1):54-7. PubMed ID: 23038690
[TBL] [Abstract][Full Text] [Related]
3. The diagnostic utility of bone marrow trephine biopsies.
Sitalakshmi S; Srikrishna A; Devi S; Damodar P; Alexander B
Indian J Pathol Microbiol; 2005 Apr; 48(2):173-6. PubMed ID: 16758657
[TBL] [Abstract][Full Text] [Related]
4. Bone marrow trephine biopsy as an adjunct to bone marrow aspiration.
Nanda A; Basu S; Marwaha N
J Assoc Physicians India; 2002 Jul; 50():893-5. PubMed ID: 12126342
[TBL] [Abstract][Full Text] [Related]
5. Diagnosis and classification of malignant lymphoma and related entities in the bone marrow trephine biopsy.
Fend F; Kremer M
Pathobiology; 2007; 74(2):133-43. PubMed ID: 17587884
[TBL] [Abstract][Full Text] [Related]
6. Failed or inadequate bone marrow aspiration: a fast, simple and cost-effective method to produce a cell suspension from a core biopsy specimen.
Novotny JR; Schmücker U; Staats B; Dührsen U
Clin Lab Haematol; 2005 Feb; 27(1):33-40. PubMed ID: 15686505
[TBL] [Abstract][Full Text] [Related]
7. Optimal processing of bone marrow trephine biopsy: the Hammersmith Protocol.
Naresh KN; Lampert I; Hasserjian R; Lykidis D; Elderfield K; Horncastle D; Smith N; Murray-Brown W; Stamp GW
J Clin Pathol; 2006 Sep; 59(9):903-11. PubMed ID: 16935969
[TBL] [Abstract][Full Text] [Related]
8. Making the most of bone marrow trephine biopsy.
Wilkins BS; Clark DM
Histopathology; 2009 Dec; 55(6):631-40. PubMed ID: 19878351
[TBL] [Abstract][Full Text] [Related]
9. The role of peripheral blood, bone marrow aspirate and especially bone marrow trephine biopsy in distinguishing atypical chronic myeloid leukemia from chronic granulocytic leukemia and chronic myelomonocytic leukemia.
Xubo G; Xingguo L; Xianguo W; Rongzhen X; Xibin X; Lin W; Lei Z; Xiaohong Z; Genbo X; Xiaoying Z
Eur J Haematol; 2009 Oct; 83(4):292-301. PubMed ID: 19500135
[TBL] [Abstract][Full Text] [Related]
10. Ultrasonic decalcification offers new perspectives for rapid FISH, DNA, and RT-PCR analysis in bone marrow trephines.
Reineke T; Jenni B; Abdou MT; Frigerio S; Zubler P; Moch H; Tinguely M
Am J Surg Pathol; 2006 Jul; 30(7):892-6. PubMed ID: 16819333
[TBL] [Abstract][Full Text] [Related]
11. Low-temperature glycol methacrylate resin embedding method: A protocol suitable for bone marrow immunohistochemistry, PCR, and fish analysis.
Zhang Q; Wang J; Wu H; Zhang L; Zhou J; Ye Q; Shao X; Guan C; Xu J; Yang Y; Zhou R; Ouyang J
Microsc Res Tech; 2010 Oct; 73(11):1067-71. PubMed ID: 20196105
[TBL] [Abstract][Full Text] [Related]
12. Experience with bone marrow trephine biopsy.
Rege JD; Phatak AM; Issac R; Bichile SK
J Assoc Physicians India; 1992 Apr; 40(4):247-8. PubMed ID: 1452533
[TBL] [Abstract][Full Text] [Related]
13. ICSH guidelines for the standardization of bone marrow immunohistochemistry.
Torlakovic EE; Brynes RK; Hyjek E; Lee SH; Kreipe H; Kremer M; McKenna R; Sadahira Y; Tzankov A; Reis M; Porwit A;
Int J Lab Hematol; 2015 Aug; 37(4):431-49. PubMed ID: 25977137
[TBL] [Abstract][Full Text] [Related]
14. [Bone marrow biopsy: processing and use of molecular techniques].
Quintanilla-Martinez L; Tinguely M; Bonzheim I; Fend F
Pathologe; 2012 Nov; 33(6):481-9. PubMed ID: 23085692
[TBL] [Abstract][Full Text] [Related]
15. Correlation between molecular and histopathological diagnoses of B cell lymphomas in bone marrow biopsy and aspirates.
Ilgenfritz RB; Kayasut K; Le Tourneau A; Calendini OA; Ouafi L; Marzac C; Diebold J; Devez F; Ducruit V; Bouchet PE; Audouin J; Molina TJ
J Clin Pathol; 2009 Apr; 62(4):357-60. PubMed ID: 19329714
[TBL] [Abstract][Full Text] [Related]
16. Ancillary techniques in bone marrow pathology: molecular diagnostics on bone marrow trephine biopsies.
Fend F; Bock O; Kremer M; Specht K; Quintanilla-Martinez L
Virchows Arch; 2005 Dec; 447(6):909-19. PubMed ID: 16231178
[TBL] [Abstract][Full Text] [Related]
17. ICSH guidelines for the standardization of bone marrow specimens and reports.
Lee SH; Erber WN; Porwit A; Tomonaga M; Peterson LC;
Int J Lab Hematol; 2008 Oct; 30(5):349-64. PubMed ID: 18822060
[TBL] [Abstract][Full Text] [Related]
18. Pitfalls in bone marrow pathology: avoiding errors in bone marrow trephine biopsy diagnosis.
Wilkins BS
J Clin Pathol; 2011 May; 64(5):380-6. PubMed ID: 21325142
[TBL] [Abstract][Full Text] [Related]
19. [The usefulness of bone marrow biopsy in haematology (author's transl)].
Campuzano G; Bedoya V; Restrepo A; Maya LM
Sangre (Barc); 1978; 23(2):138-48. PubMed ID: 653549
[No Abstract] [Full Text] [Related]
20. [Bone biopsy in hematology].
Badone M; Fontana S
Minerva Med; 1985 Feb; 76(5):177-81. PubMed ID: 3974930
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]