60 related articles for article (PubMed ID: 18243955)
1. RE Pulse Shapes for Selective Excitation in NMR Imaging.
Smith MR
IEEE Trans Med Imaging; 1985; 4(2):79-83. PubMed ID: 18243955
[TBL] [Abstract][Full Text] [Related]
2. Principles of MR image formation and reconstruction.
Duerk JL
Magn Reson Imaging Clin N Am; 1999 Nov; 7(4):629-59. PubMed ID: 10631672
[TBL] [Abstract][Full Text] [Related]
3. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging].
Pauly J; Le Roux P; Nishimura D; Macovski A
IEEE Trans Med Imaging; 1991; 10(1):53-65. PubMed ID: 18222800
[TBL] [Abstract][Full Text] [Related]
4. Short, shaped pulses in a large magnetic field gradient.
Coarna C; Newling B
J Magn Reson; 2009 Feb; 196(2):127-32. PubMed ID: 19038562
[TBL] [Abstract][Full Text] [Related]
5. Practical pulse synthesis via the discrete inverse scattering transform.
Magland J; Epstein CL
J Magn Reson; 2005 Jan; 172(1):63-78. PubMed ID: 15589409
[TBL] [Abstract][Full Text] [Related]
6. Quantitative time- and frequency-domain analysis of the two-pulse COSY revamped by asymmetric Z-gradient echo detection NMR experiment: Theoretical and experimental aspects, time-zero data truncation artifacts, and radiation damping.
Kirsch S; Hull WE
J Chem Phys; 2008 Jul; 129(4):044505. PubMed ID: 18681658
[TBL] [Abstract][Full Text] [Related]
7. Combined simulated annealing and Shinnar-Le Roux pulse design of slice-multiplexed RF pulses for multi-slice imaging.
Lee KJ; Paley MN; Wild JM
J Magn Reson; 2006 Sep; 182(1):133-42. PubMed ID: 16828567
[TBL] [Abstract][Full Text] [Related]
8. Minimum energy pulse synthesis via the inverse scattering transform.
Epstein CL
J Magn Reson; 2004 Apr; 167(2):185-210. PubMed ID: 15040975
[TBL] [Abstract][Full Text] [Related]
9. Adiabatic slice-selective excitation for surface coils.
Shen J; Rothman DL
J Magn Reson; 1997 Jan; 124(1):72-9. PubMed ID: 9169211
[TBL] [Abstract][Full Text] [Related]
10. Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 tesla.
Martirosian P; Boss A; Deimling M; Kiefer B; Schraml C; Schwenzer NF; Claussen CD; Schick F
Invest Radiol; 2008 Jan; 43(1):16-26. PubMed ID: 18097273
[TBL] [Abstract][Full Text] [Related]
11. Fast imaging with the MMME sequence.
Cho H; Chavez L; Sigmund EE; Madio DP; Song YQ
J Magn Reson; 2006 May; 180(1):18-28. PubMed ID: 16427794
[TBL] [Abstract][Full Text] [Related]
12. Echo projection imaging-a method to obtain NMR images undistorted by magnetic field inhomogeneities.
Bendel P
IEEE Trans Med Imaging; 1985; 4(2):114-9. PubMed ID: 18243959
[TBL] [Abstract][Full Text] [Related]
13. Slice-selected LED and BPPLED: application of slice selection to DOSY.
Park KD; Lee YJ
Magn Reson Chem; 2006 Sep; 44(9):887-91. PubMed ID: 16927252
[TBL] [Abstract][Full Text] [Related]
14. A multiple-pulse sequence for improved selective excitation in magnetic resonance imaging.
Nishimura DG
Med Phys; 1985; 12(4):413-8. PubMed ID: 4033586
[TBL] [Abstract][Full Text] [Related]
15. Studies on characteristics of resistive power calculated with discrete Fourier transform in a pulse-modulated radio frequency discharge.
Huo WG; Zhang H; Ding ZF
Rev Sci Instrum; 2015 Feb; 86(2):023508. PubMed ID: 25725843
[TBL] [Abstract][Full Text] [Related]
16. New FOCI pulses with reduced radiofrequency power requirements.
Shen J; Chen Z; Yang J
J Magn Reson Imaging; 2004 Sep; 20(3):531-7. PubMed ID: 15332264
[TBL] [Abstract][Full Text] [Related]
17. Spatially selective RF pulses and the effects of digitization on their performance.
Slotboom J; Creyghton JH; Korbee D; Mehlkopf AF; Bovée WM
Magn Reson Med; 1993 Dec; 30(6):732-40. PubMed ID: 8139455
[TBL] [Abstract][Full Text] [Related]
18. Chebyshev series for designing RF pulses employing an optimal control approach.
Ulloa JL; Guarini M; Guesalaga A; Irarrazaval P
IEEE Trans Med Imaging; 2004 Nov; 23(11):1445-52. PubMed ID: 15554131
[TBL] [Abstract][Full Text] [Related]
19. Slice-selective FID acquisition, localized by outer volume suppression (FIDLOVS) for (1)H-MRSI of the human brain at 7 T with minimal signal loss.
Henning A; Fuchs A; Murdoch JB; Boesiger P
NMR Biomed; 2009 Aug; 22(7):683-96. PubMed ID: 19259944
[TBL] [Abstract][Full Text] [Related]
20. Spatial excitation using variable-density spiral trajectories.
Schröder C; Börnert P; Aldefeld B
J Magn Reson Imaging; 2003 Jul; 18(1):136-41. PubMed ID: 12815650
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]