These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 18244102)

  • 1. SPICE model for lossy piezoceramic transducers.
    Puttmer A; Hauptmann P; Lucklum R; Krause O; Henning B
    IEEE Trans Ultrason Ferroelectr Freq Control; 1997; 44(1):60-6. PubMed ID: 18244102
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SPICE model for lossy piezoelectric polymers.
    Dahiya RS; Valle M; Lorenzelli L
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Feb; 56(2):387-95. PubMed ID: 19251526
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modeling of functionally graded piezoelectric ultrasonic transducers.
    Rubio WM; Buiochi F; Adamowski JC; Silva EC
    Ultrasonics; 2009 May; 49(4-5):484-94. PubMed ID: 19230947
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Theoretical modeling and equivalent electric circuit of a bimorph piezoelectric micromachined ultrasonic transducer.
    Sammoura F; Kim SG
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 May; 59(5):990-8. PubMed ID: 22622984
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of acoustic impedances of multi matching layers for narrowband ultrasonic airborne transducers at frequencies <2.5 MHz - Application of a genetic algorithm.
    Saffar S; Abdullah A
    Ultrasonics; 2012 Jan; 52(1):169-85. PubMed ID: 21893329
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Modelling nonlinearity in piezoceramic transducers: From equations to nonlinear equivalent circuits.
    Parenthoine D; Tran-Huu-Hue LP; Haumesser L; Vander Meulen F; Lematre M; Lethiecq M
    Ultrasonics; 2011 Feb; 51(2):109-14. PubMed ID: 20855096
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrasound transducer models for piezoelectric polymer films.
    Brown LF; Carlson DL
    IEEE Trans Ultrason Ferroelectr Freq Control; 1989; 36(3):313-8. PubMed ID: 18284984
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single-element ultrasonic transducer modeling using a hybrid FD-PSTD method.
    Filoux E; Levassort F; Callé S; Certon D; Lethiecq M
    Ultrasonics; 2009 Dec; 49(8):611-4. PubMed ID: 19625065
    [TBL] [Abstract][Full Text] [Related]  

  • 9. c-Axis zig-zag ZnO film ultrasonic transducers for designing longitudinal and shear wave resonant frequencies and modes.
    Yanagitani T; Morisato N; Takayanagi S; Matsukawa M; Watanabe Y
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 May; 58(5):1062-8. PubMed ID: 21622061
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experiment and simulation validated analytical equivalent circuit model for piezoelectric micromachined ultrasonic transducers.
    Smyth K; Kim SG
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Apr; 62(4):744-65. PubMed ID: 25881352
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiation impedance and equivalent circuit for piezoelectric ultrasonic composite transducers of vibrational mode-conversion.
    Lin S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Jan; 59(1):139-49. PubMed ID: 22293744
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Definition and measurement of the normalized electrical impedance of lossy piezoelectric resonators for ultrasonic transducers.
    San Emeterio JL ; Ramos A; Sanz PT; Cegarra M
    Ultrasonics; 2000 Mar; 38(1-8):140-4. PubMed ID: 10829646
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison between piezoelectric material properties obtained by using low-voltage magnitude frequency sweeping and high-level short impulse signals.
    Petošić A; Budimir M; Pavlović N
    Ultrasonics; 2013 Aug; 53(6):1192-9. PubMed ID: 23562492
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of unidirectional broadband piezoelectric spherical shell transducers for underwater acoustics.
    Aronov B; Brown DA; Bachand CL; Yan X
    J Acoust Soc Am; 2012 Mar; 131(3):2079-90. PubMed ID: 22423704
    [TBL] [Abstract][Full Text] [Related]  

  • 15. PSpice Modeling of a Sandwich Piezoelectric Ceramic Ultrasonic Transducer in Longitudinal Vibration.
    Wei X; Yang Y; Yao W; Zhang L
    Sensors (Basel); 2017 Sep; 17(10):. PubMed ID: 28973996
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New transmission line analogy applied to single and multilayered piezoelectric transducers.
    Dion JL
    IEEE Trans Ultrason Ferroelectr Freq Control; 1993; 40(5):577-83. PubMed ID: 18263222
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Efficiency of excitation of piezoceramic transducers at antiresonance frequency.
    Mezheritsky AV
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Apr; 49(4):484-94. PubMed ID: 11989704
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elastic, dielectric, and piezoelectric losses in piezoceramics: how it works all together.
    Mezheritsky AV
    IEEE Trans Ultrason Ferroelectr Freq Control; 2004 Jun; 51(6):695-707. PubMed ID: 15244283
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An equivalent circuit model for transmitting capacitive micromachined ultrasonic transducers in collapse mode.
    Olcum S; Yamaner FY; Bozkurt A; Köymen H; Atalar A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Jul; 58(7):1468-77. PubMed ID: 21768031
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Study on the radial composite piezoelectric ceramic transducer in radial vibration.
    Lin S
    Ultrasonics; 2007 Mar; 46(1):51-9. PubMed ID: 17166538
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.