These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 18244356)

  • 1. Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection.
    Beard PC; Perennes F; Mills TN
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(6):1575-82. PubMed ID: 18244356
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: a comparison with PVDF needle and membrane hydrophones.
    Beard PC; Hurrell AM; Mills TN
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(1):256-64. PubMed ID: 18238538
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer.
    Beard PC; Mills TN
    Appl Opt; 1996 Feb; 35(4):663-75. PubMed ID: 21069054
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Two-dimensional ultrasound receive array using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging.
    Beard PC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Jun; 52(6):1002-12. PubMed ID: 16118981
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Fabry-Perot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure.
    Morris P; Hurrell A; Shaw A; Zhang E; Beard P
    J Acoust Soc Am; 2009 Jun; 125(6):3611-22. PubMed ID: 19507943
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Broadband ultrasound field mapping system using a wavelength tuned, optically scanned focused laser beam to address a Fabry Perot polymer film sensor.
    Zhang E; Beard P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Jul; 53(7):1330-8. PubMed ID: 16889340
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Progress in developing a thermal method for measuring the output power of medical ultrasound transducers that exploits the pyroelectric effect.
    Zeqiri B; Zauhar G; Hodnett M; Barrie J
    Ultrasonics; 2011 May; 51(4):420-4. PubMed ID: 21163509
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Wide-band piezoelectric polymer acoustic sources.
    Lewin PA; Schafer ME
    IEEE Trans Ultrason Ferroelectr Freq Control; 1988; 35(2):175-85. PubMed ID: 18290144
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Glancing angle deposited nanostructured film Fabry-Perot etalons for optical detection of ultrasound.
    Hajireza P; Krause K; Brett M; Zemp R
    Opt Express; 2013 Mar; 21(5):6391-400. PubMed ID: 23482209
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In-line silica capillary tube all-silica fiber-optic Fabry-Perot interferometric sensor for detecting high intensity focused ultrasound fields.
    Wang DH; Wang SJ; Jia PG
    Opt Lett; 2012 Jun; 37(11):2046-8. PubMed ID: 22660116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photothermally tunable Fabry-Pérot fiber interferometer for photoacoustic mesoscopy.
    Chen B; Chen Y; Ma C
    Biomed Opt Express; 2020 May; 11(5):2607-2618. PubMed ID: 32499947
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wide bandwidth dual-frequency ultrasound measurements based on fiber laser sensing technology.
    Lyu C; Liu Y; Wu C
    Appl Opt; 2016 Jul; 55(19):5057-62. PubMed ID: 27409190
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Embedded fiber-optic Fabry-Perot ultrasound sensor.
    Alcoz JJ; Lee CE; Taylor HF
    IEEE Trans Ultrason Ferroelectr Freq Control; 1990; 37(4):302-6. PubMed ID: 18285045
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wideband spherically focused PVDF acoustic sources for calibration of ultrasound hydrophone probes.
    Selfridge A; Lewin PA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(6):1372-6. PubMed ID: 18238683
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Acoustic performance and clinical use of a fibreoptic hydrophone.
    Coleman AJ; Draguioti E; Tiptaf R; Shotri N; Saunders JE
    Ultrasound Med Biol; 1998 Jan; 24(1):143-51. PubMed ID: 9483782
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Polymer waveguide Fabry-Perot resonator for high-frequency ultrasound detection.
    Tadayon MA; Baylor ME; Ashkenazi S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Dec; 61(12):2132-8. PubMed ID: 25474787
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rapid Spatial Mapping of Focused Ultrasound Fields Using a Planar Fabry-Pérot Sensor.
    Martin E; Zhang EZ; Guggenheim JA; Beard PC; Treeby BE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Nov; 64(11):1711-1722. PubMed ID: 28880170
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microfiber Fabry-Perot interferometer fabricated by taper-drawing technique and its application as a radio frequency interrogated refractive index sensor.
    Zhang J; Sun Q; Liang R; Wo J; Liu D; Shum P
    Opt Lett; 2012 Jul; 37(14):2925-7. PubMed ID: 22825180
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wideband and frequency-tunable microwave generation using an optoelectronic oscillator incorporating a Fabry-Perot laser diode with external optical injection.
    Pan S; Yao J
    Opt Lett; 2010 Jun; 35(11):1911-3. PubMed ID: 20517459
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fiber-optic ultrasonic hydrophone using short Fabry-Perot cavity with multilayer reflectors deposited on small stub.
    Kim KS; Mizuno Y; Nakamura K
    Ultrasonics; 2014 Apr; 54(4):1047-51. PubMed ID: 24411816
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.