These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 18248061)

  • 1. Numerical and experimental study of a thermal probe for measuring groundwater velocity.
    Guaraglia DO; Mayosky MA; Pousa JL; Kruse EE
    Rev Sci Instrum; 2008 Jan; 79(1):015102. PubMed ID: 18248061
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Interpreting velocities from heat-based flow sensors by numerical simulation.
    Su GW; Freifeld BM; Oldenburg CM; Jordan PD; Daley PF
    Ground Water; 2006; 44(3):386-93. PubMed ID: 16681519
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Positive solution of two-dimensional solute transport in heterogeneous aquifers.
    Herrera P; Valocchi A
    Ground Water; 2006; 44(6):803-13. PubMed ID: 17087752
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Orientation and related buoyancy effects in low-velocity flow boiling.
    Merte H; Schultz WW; Liu Q; Keller RB
    Ann N Y Acad Sci; 2009 Apr; 1161():202-10. PubMed ID: 19426318
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of heat transfer coefficients by nuclear magnetic resonance.
    Gultekin DH; Gore JC
    Magn Reson Imaging; 2008 Nov; 26(9):1323-8. PubMed ID: 18524523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Numerical analysis of temperature and thermal dose response of biological tissues to thermal non-equilibrium during hyperthermia therapy.
    Yuan P
    Med Eng Phys; 2008 Mar; 30(2):135-43. PubMed ID: 17493861
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a proposed velocity equation for improved exothermic process control.
    McKernan JL; Ellenbecker MJ; Holcroft CA; Petersen MR
    Ann Occup Hyg; 2007 Jun; 51(4):357-69. PubMed ID: 17519275
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Numerical study on thermal field of microwave ablation with water-cooled antenna.
    Lu Y; Nan Q; Li L; Liu Y
    Int J Hyperthermia; 2009 Mar; 25(2):108-15. PubMed ID: 19337911
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The thermal impact of subsurface building structures on urban groundwater resources - A paradigmatic example.
    Epting J; Scheidler S; Affolter A; Borer P; Mueller MH; Egli L; GarcĂ­a-Gil A; Huggenberger P
    Sci Total Environ; 2017 Oct; 596-597():87-96. PubMed ID: 28426989
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of network identification by deconvolution method to the thermal analysis of the pump-probe transient thermoreflectance signal.
    Ezzahri Y; Shakouri A
    Rev Sci Instrum; 2009 Jul; 80(7):074903. PubMed ID: 19655973
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Effects of probe configuration on the measurement of bio-tissue thermal physical parameters using step-temperature technique].
    Yang K; Liu W; Luo Q
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Oct; 24(5):1001-7. PubMed ID: 18027684
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A high-precision apparatus for the characterization of thermal interface materials.
    Kempers R; Kolodner P; Lyons A; Robinson AJ
    Rev Sci Instrum; 2009 Sep; 80(9):095111. PubMed ID: 19791968
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of chronopotentiometry to determine the thickness of diffusion layer adjacent to an ion-exchange membrane under natural convection.
    Larchet C; Nouri S; Auclair B; Dammak L; Nikonenko V
    Adv Colloid Interface Sci; 2008 Jun; 139(1-2):45-61. PubMed ID: 18308286
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A transistor based air flow transducer for thermohygrometric control of neonatal ventilatory applications.
    Schena E; Silvestri S
    Rev Sci Instrum; 2008 Oct; 79(10):104301. PubMed ID: 19044734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A simple differential steady-state method to measure the thermal conductivity of solid bulk materials with high accuracy.
    Kraemer D; Chen G
    Rev Sci Instrum; 2014 Feb; 85(2):025108. PubMed ID: 24593397
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An improved theoretical model for thermal diffusion coefficient in liquid hydrocarbon mixtures: Comparison between experimental and numerical results.
    Yan Y; Blanco P; Saghir MZ; Bou-Ali MM
    J Chem Phys; 2008 Nov; 129(19):194507. PubMed ID: 19026066
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Temperature measurement by thermal strain imaging with diagnostic power ultrasound, with potential for thermal index determination.
    Liang HD; Zhou LX; Wells PN; Halliwell M
    Ultrasound Med Biol; 2009 May; 35(5):773-80. PubMed ID: 19243879
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A sensitivity analysis of the step-temperature technique for measurement of local tissue blood perfusion.
    Yang K; Liu W
    J Med Eng Technol; 2008; 32(1):73-82. PubMed ID: 18183522
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measuring artificial recharge with fiber optic distributed temperature sensing.
    Becker MW; Bauer B; Hutchinson A
    Ground Water; 2013; 51(5):670-8. PubMed ID: 23110559
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modeling of thermal processes in high pressure liquid chromatography: II. Thermal heterogeneity at very high pressures.
    Kaczmarski K; Gritti F; Kostka J; Guiochon G
    J Chromatogr A; 2009 Sep; 1216(38):6575-86. PubMed ID: 19665717
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.