These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 18248519)

  • 1. Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula.
    Campos RP; Chula DC; Perreto S; Riella MC; do Nascimento MM
    Semin Dial; 2008; 21(3):269-73. PubMed ID: 18248519
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monitoring and Surveillance of Hemodialysis Vascular Access Using StenTec and Physical Exam.
    Dhamija R; Nash SK; Nguyen SV; Slack K; Tadeo J
    Semin Dial; 2015; 28(3):299-304. PubMed ID: 25346002
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of QB stress test as a useful tool in the detection of native arteriovenous fistula stenosis: results after 22 months of follow-up.
    Bonforte G; Pogliani D; Brenna S; Martinelli D; Bernardi LE; D'Amico M; Mangano S; Rossi E; Genovesi S; Grillo C
    Nephrol Dial Transplant; 2010 Jun; 25(6):1943-9. PubMed ID: 20064952
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of physical examination in the detection of arteriovenous graft stenosis.
    Leon C; Orozco-Vargas LC; Krishnamurthy G; Choi KL; Mercado C; Merrill D; Thomas I; Salman L; Artikov S; Bourgoignie JJ; Asif A
    Semin Dial; 2008; 21(1):85-8. PubMed ID: 18251963
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of physical examination in the detection of arteriovenous fistula stenosis.
    Asif A; Leon C; Orozco-Vargas LC; Krishnamurthy G; Choi KL; Mercado C; Merrill D; Thomas I; Salman L; Artikov S; Bourgoignie JJ
    Clin J Am Soc Nephrol; 2007 Nov; 2(6):1191-4. PubMed ID: 17928468
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [How to predict thrombosis of arteriovenous fistule?].
    Kapun S; Zibar L
    Acta Med Croatica; 2008 Feb; 62(1):9-13. PubMed ID: 18365494
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Utility of intra-access pressure].
    Caro P; Delgado R; Dapena F; Aguilera A
    Nefrologia; 2004; 24(4):357-63. PubMed ID: 15455496
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance of physical examination versus ultrasonography to detect stenosis in haemodialysis arteriovenous fistula.
    Maldonado-Cárceles AB; García-Medina J; Torres-Cantero AM
    J Vasc Access; 2017 Jan; 18(1):30-34. PubMed ID: 27834455
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of the severity of outflow stenosis of hemodialysis fistulas with a pulse- and thrill-based scoring system.
    Chen MC; Weng MJ; Chang BC; Lai HC; Wu MY; Fu CY; Liu YC; Chi WC
    BMC Nephrol; 2020 Jul; 21(1):304. PubMed ID: 32711458
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Secondary arteriovenous fistulas: converting prosthetic AV grafts to autogenous dialysis access.
    Slayden GC; Spergel L; Jennings WC
    Semin Dial; 2008; 21(5):474-82. PubMed ID: 18627564
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Vascular access surveillance with blood flow monitoring: a prospective study with 65 patients].
    Roca-Tey R; Samon Guasch R; Ibrik O; García-Madrid C; Herranz JJ; García-González L; Viladoms Guerra J
    Nefrologia; 2004; 24(3):246-52. PubMed ID: 15283315
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of frequency of complications of arterio venous fistula in patients on dialysis: a two-year single center study from Iran.
    Derakhshanfar A; Gholyaf M; Niayesh A; Bahiraii S
    Saudi J Kidney Dis Transpl; 2009 Sep; 20(5):872-5. PubMed ID: 19736495
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparing non-invasive diagnostic methods for arteriovenous fistula stenosis: a prospective study.
    Raksasuk S; Naweera W; Rojwatcharapibarn S; Srithongkul T
    J Ultrasound; 2023 Sep; 26(3):687-693. PubMed ID: 36319839
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Study of arteriovenous fistula function by the temperature gradient method using the Twister™ device.
    Roca-Tey R; Samon R; Ibrik O; Roda A; González-Oliva JC; Viladoms J
    Nefrologia; 2012; 32(2):172-9. PubMed ID: 22425797
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnosis of arteriovenous fistula dysfunction.
    Vachharajani TJ
    Semin Dial; 2012 Jul; 25(4):445-50. PubMed ID: 22694731
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effective ionic dialysance/blood flow rate ratio: an indicator of access recirculation in arteriovenous fistulae.
    Mohan S; Madhrira M; Mujtaba M; Agarwala R; Pogue V; Cheng JT
    ASAIO J; 2010; 56(5):427-33. PubMed ID: 20577081
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Endovascular management of the "failing to mature" arteriovenous fistula.
    Nassar GM
    Tech Vasc Interv Radiol; 2008 Sep; 11(3):175-80. PubMed ID: 19100946
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physical examination of arteriovenous fistulae by a renal fellow: does it compare favorably to an experienced interventionalist?
    Leon C; Asif A
    Semin Dial; 2008; 21(6):557-60. PubMed ID: 18764788
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Experience in the surveillance of arteriovenous fistula in Verbania, Italy].
    Borzumati M; De Gregorio F; Funaro L; Guazzoni A; Baroni A
    G Ital Nefrol; 2007; 24(4):327-32. PubMed ID: 17659504
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Integrating vascular access surveillance with clinical monitoring for stenosis prediction.
    Wu CK; Lin CH
    J Nephrol; 2024 Mar; 37(2):461-470. PubMed ID: 37980698
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.