These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 1826504)

  • 21. Comparison of reversed-phase and weak anion-exchange high-performance liquid chromatographic methods for peptide separations.
    Dizdaroglu M; Krutzsch HC
    J Chromatogr; 1983 Jul; 264(2):223-9. PubMed ID: 6193134
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Simultaneous determination of bovine alpha-lactalbumin and beta-lactoglobulin in infant formulae by ultra-high-performance liquid chromatography-mass spectrometry.
    Ren Y; Han Z; Chu X; Zhang J; Cai Z; Wu Y
    Anal Chim Acta; 2010 May; 667(1-2):96-102. PubMed ID: 20441872
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of column degradation on the reversed-phase high-performance liquid chromatographic separation of peptides and proteins.
    Glajch JL; Kirkland JJ; Köhler J
    J Chromatogr; 1987 Jan; 384():81-90. PubMed ID: 3818859
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effects of pressure and frictional heating on protein separation using monolithic columns in reversed-phase chromatography.
    Mann BF; Makarov AA; Wang H; Welch CJ
    J Chromatogr A; 2017 Mar; 1489():58-64. PubMed ID: 28193469
    [TBL] [Abstract][Full Text] [Related]  

  • 25. An aqueous hydroxypropylstarch-poly(ethylene glycol) two-phase system for extraction of alpha-lactalbumin and beta-lactoglobulin from bovine whey.
    Ortín A; Cebrian JA; López-Pérez MJ; Johansson G
    Bioseparation; 1991; 2(4):197-205. PubMed ID: 1368085
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Characterization of capillary-channeled polymer fiber stationary phases for high-performance liquid chromatography protein separations: Comparative analysis with a packed-bed column.
    Nelson DM; Marcus RK
    Anal Chem; 2006 Dec; 78(24):8462-71. PubMed ID: 17165840
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Identification and isolation of human insulin A and B chains by high-performance liquid chromatography.
    Ladrón de Guevara O; Estrada G; Antonio S; Alvarado X; Guereca L; Zamudio F; Bolívar F
    J Chromatogr; 1985 Dec; 349(1):91-8. PubMed ID: 3910674
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Alternative mobile phases for the reversed-phase high-performance liquid chromatography of peptides and proteins.
    Welinder BS; Sørensen HH
    J Chromatogr; 1991 Jan; 537(1-2):181-99. PubMed ID: 2050779
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Purification and physicochemical characterization of ovine beta-lactoglobulin and alpha-lactalbumin.
    El-Zahar K; Sitohy M; Dalgalarrondo M; Choiset Y; Métro F; Haertlé T; Chobert JM
    Nahrung; 2004 Jun; 48(3):177-83. PubMed ID: 15285107
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Pillar array columns for peptide separations in nanoscale reversed-phase chromatography.
    Tóth G; Panić-Janković T; Mitulović G
    J Chromatogr A; 2019 Oct; 1603():426-432. PubMed ID: 31301798
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Separation of proteins by consecutive sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis and reversed phase high performance liquid chromatography.
    Kaplan B; Pras M
    Biomed Chromatogr; 1991 Mar; 5(2):86-9. PubMed ID: 1868264
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Conformational effects in reversed-phase high-performance liquid chromatography of polypeptides. I. Resolution of insulin variants.
    Purcell AW; Aguilar MI; Hearn MT
    J Chromatogr A; 1995 Sep; 711(1):61-70. PubMed ID: 7496495
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Optimization of high-performance liquid chromatographic peptide separations with alternative mobile and stationary phases.
    Young PM; Wheat TE
    J Chromatogr; 1990 Jul; 512():273-81. PubMed ID: 2172265
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Experimental models for optimization of insulin separation on reversed phase columns.
    Dimov N; Simeonov S
    Biomed Chromatogr; 1994; 8(1):32-6. PubMed ID: 8130631
    [TBL] [Abstract][Full Text] [Related]  

  • 35. High performance liquid chromatographic properties of peptides and proteins on a dihydroxyalkyl bonded silica stationary phase.
    Meyerson LR; Abraham KI
    Peptides; 1986; 7(3):481-9. PubMed ID: 3022255
    [TBL] [Abstract][Full Text] [Related]  

  • 36. High-performance liquid chromatography of insulin.
    McLeod A; Wood SP
    J Chromatogr; 1984 Mar; 285(2):319-31. PubMed ID: 6371034
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Perfluorinated acid alternatives to trifluoroacetic acid for reversed-phase high-performance liquid chromatography.
    Pearson JD; McCroskey MC
    J Chromatogr A; 1996 Oct; 746(2):277-81. PubMed ID: 8916558
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Selective separation of the major whey proteins using ion exchange membranes.
    Goodall S; Grandison AS; Jauregi PJ; Price J
    J Dairy Sci; 2008 Jan; 91(1):1-10. PubMed ID: 18096919
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Fractionation of sheep cheese whey by a scalable method to sequentially isolate bioactive proteins.
    Pilbrow J; Bekhit AEA; Carne A
    Food Chem; 2016 Jul; 203():165-174. PubMed ID: 26948602
    [TBL] [Abstract][Full Text] [Related]  

  • 40. High-speed gradient separations of peptides and proteins using polymer-monolithic poly(styrene-co-divinylbenzene) capillary columns at ultra-high pressure.
    Vaast A; Nováková L; Desmet G; de Haan B; Swart R; Eeltink S
    J Chromatogr A; 2013 Aug; 1304():177-82. PubMed ID: 23885671
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.