BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 18267572)

  • 1. Estimation of mean frequency and variance of ultrasonic Doppler signal by using second-order autoregressive model.
    Ahn YB; Park SB
    IEEE Trans Ultrason Ferroelectr Freq Control; 1991; 38(3):172-82. PubMed ID: 18267572
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An improved mean frequency estimator for ultrasonic color flow imaging using second-order autoregressive model.
    Wang P; Shen Y; Wang X
    Conf Proc IEEE Eng Med Biol Soc; 2005; 2005():5643-6. PubMed ID: 17281536
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved estimation of low velocities in color Doppler imaging by adapting the mean frequency estimator to the clutter rejection filter.
    Herment A; Demoment G; Dumée P
    IEEE Trans Biomed Eng; 1996 Sep; 43(9):919-27. PubMed ID: 9214807
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Low-order AR models for mean and maximum frequency estimation in the context of Doppler color flow mapping.
    Loupas T; McDicken WN
    IEEE Trans Ultrason Ferroelectr Freq Control; 1990; 37(6):590-601. PubMed ID: 18285083
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An adaptive clutter rejection method based on AR model in color flow imaging.
    Feng N; Zhang J; Wang W
    Ultrasonics; 2006 Dec; 44 Suppl 1():e85-8. PubMed ID: 16860357
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A new MTI scheme in ultrasonic color flow mapping systems].
    Feng N; Zhang J; Shen Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Apr; 23(2):413-8. PubMed ID: 16706379
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new adaptive mean frequency estimator: application to constant variance color flow mapping.
    Herment A; Demoment G; Dumee P; Guglielmi JP; Delouche A
    IEEE Trans Ultrason Ferroelectr Freq Control; 1993; 40(6):796-804. PubMed ID: 18263248
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison method for mean frequency estimators for Doppler ultrasound.
    Brands PJ; Hoeks AP
    Ultrason Imaging; 1992 Oct; 14(4):367-86. PubMed ID: 1296340
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Time-domain estimation of the center frequency and spread of Doppler spectra in diagnostic ultrasound.
    Kristoffersen K
    IEEE Trans Ultrason Ferroelectr Freq Control; 1988; 35(6):685-700. PubMed ID: 18290204
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Time-domain estimation of the center frequency and spread of Doppler spectra in diagnostic ultrasound.
    Kristoffersen K
    IEEE Trans Ultrason Ferroelectr Freq Control; 1988; 35(4):484-97. PubMed ID: 18290178
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new wideband spread target maximum likelihood estimator for blood velocity estimation. I. Theory.
    Ferrara KW; Algazi VR
    IEEE Trans Ultrason Ferroelectr Freq Control; 1991; 38(1):1-16. PubMed ID: 18267551
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new time-domain narrowband velocity estimation technique for Doppler ultrasound flow imaging. II. Comparative performance assessment.
    Vaitkus PJ; Cobbold RC; Johnston KW
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(4):955-71. PubMed ID: 18244250
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduced-order autoregressive modeling for center-frequency estimation.
    Kuc R; Li H
    Ultrason Imaging; 1985 Jul; 7(3):244-51. PubMed ID: 4095824
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance of a mixed Lagrange time delay estimation autoregressive (MLTDEAR) model for single-image signal- to-noise ratio estimation in scanning electron microscopy.
    Sim KS; Chuah HT; Zheng C
    J Microsc; 2005 Jul; 219(Pt 1):1-17. PubMed ID: 15998361
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimal velocity estimation in ultrasound color flow imaging in presence of clutter.
    Løvstakken L; Bjaerum S; Torp H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Mar; 54(3):539-49. PubMed ID: 17375823
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An adaptive approach to computing the spectrum and mean frequency of Doppler signals.
    Herment A; Giovannelli JF
    Ultrason Imaging; 1995 Jan; 17(1):1-26. PubMed ID: 7638930
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Doppler angle estimation of pulsatile flows using AR modeling.
    Yeh CK; Li PC
    Ultrason Imaging; 2002 Apr; 24(2):65-80. PubMed ID: 12199419
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Image noise variance estimation using the mixed Lagrange time-delay autoregressive model.
    Sim KS; Tso CP; Law KK
    Microsc Res Tech; 2008 Apr; 71(4):315-24. PubMed ID: 18172898
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigation of parametric spectral estimation techniques for elasticity imaging.
    Hoyt K; Forsberg F; Ophir J
    Ultrasound Med Biol; 2005 Aug; 31(8):1109-21. PubMed ID: 16085101
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Hurst exponent estimator based on autoregressive power spectrum estimation with order selection.
    Chang YC; Lai LC; Chen LH; Chang CM; Chueh CC
    Biomed Mater Eng; 2014; 24(1):1041-51. PubMed ID: 24211995
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.