These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
95 related articles for article (PubMed ID: 18267652)
21. Bayesian and least squares approaches to ultrasonic scatterer size image formation. Chaturvedi P; Insana MF IEEE Trans Ultrason Ferroelectr Freq Control; 1997; 44(1):152-60. PubMed ID: 18244112 [TBL] [Abstract][Full Text] [Related]
22. Power spectrum equalization for ultrasonic image restoration. Iraca D; Landini L; Verrazzani L IEEE Trans Ultrason Ferroelectr Freq Control; 1989; 36(2):216-22. PubMed ID: 18284971 [TBL] [Abstract][Full Text] [Related]
23. Fine-tuning the H-scan for discriminating changes in tissue scatterers. Parker KJ; Baek J Biomed Phys Eng Express; 2020 May; 6(4):045012. PubMed ID: 33444273 [TBL] [Abstract][Full Text] [Related]
24. Classification of broadband echoes from prey of a foraging Blainville's beaked whale. Jones BA; Stanton TK; Lavery AC; Johnson MP; Madsen PT; Tyack PL J Acoust Soc Am; 2008 Mar; 123(3):1753-62. PubMed ID: 18345863 [TBL] [Abstract][Full Text] [Related]
25. The spatial correlation of backscattered ultrasonic grain noise: theory and experimental validation. Yu L; Thompson RB; Margetan FJ IEEE Trans Ultrason Ferroelectr Freq Control; 2010; 57(2):363-78. PubMed ID: 20178902 [TBL] [Abstract][Full Text] [Related]
26. EEMD Domain AR Spectral Method for Mean Scatterer Spacing Estimation of Breast Tumors From Ultrasound Backscattered RF Data. Nizam NI; Alam SK; Hasan MK IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Oct; 64(10):1487-1500. PubMed ID: 28792892 [TBL] [Abstract][Full Text] [Related]
27. Spectral histogram using the minimization algorithm-theory and applications to flaw detection. Li X; Bilgutay NM; Murthy R IEEE Trans Ultrason Ferroelectr Freq Control; 1992; 39(2):279-84. PubMed ID: 18263148 [TBL] [Abstract][Full Text] [Related]
28. The effect of transducer characteristics on the estimation of Nakagami paramater as a function of scatterer concentration. Tsui PH; Wang SH Ultrasound Med Biol; 2004 Oct; 30(10):1345-53. PubMed ID: 15582234 [TBL] [Abstract][Full Text] [Related]
29. Tissue characterization based on scatterer number density estimation. Sleefe GE; Lele PP IEEE Trans Ultrason Ferroelectr Freq Control; 1988; 35(6):749-57. PubMed ID: 18290212 [TBL] [Abstract][Full Text] [Related]
30. Application of phased array techniques to coarse grain components inspection. Mahaut S; Godefroit JL; Roy O; Cattiaux G Ultrasonics; 2004 Apr; 42(1-9):791-6. PubMed ID: 15047385 [TBL] [Abstract][Full Text] [Related]
31. Localization of a small change in a multiple scattering environment without modeling of the actual medium. Rakotonarivo ST; Walker SC; Kuperman WA; Roux P J Acoust Soc Am; 2011 Dec; 130(6):3566-73. PubMed ID: 22225013 [TBL] [Abstract][Full Text] [Related]
32. Nonparametric Estimation of the Probability of Detection of Flaws in an Industrial Component, from Destructive and Nondestructive Testing Data, Using Approximate Bayesian Computation. Keller M; Popelin AL; Bousquet N; Remy E Risk Anal; 2015 Sep; 35(9):1595-610. PubMed ID: 26414699 [TBL] [Abstract][Full Text] [Related]
33. Three dimensional imaging and recognition using truncated photon counting model and parametric maximum likelihood estimator. Moon I; Javidi B Opt Express; 2009 Aug; 17(18):15709-15. PubMed ID: 19724570 [TBL] [Abstract][Full Text] [Related]
34. Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging. Christopher T IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(1):158-62. PubMed ID: 18244167 [TBL] [Abstract][Full Text] [Related]
35. A new wideband spread target maximum likelihood estimator for blood velocity estimation. II. Evaluation of estimator with experimental data. Ferrara KW; Algazi VR IEEE Trans Ultrason Ferroelectr Freq Control; 1991; 38(1):17-26. PubMed ID: 18267552 [TBL] [Abstract][Full Text] [Related]
36. Fractional brownian motion: a maximum likelihood estimator and its application to image texture. Lundahl T; Ohley WJ; Kay SM; Siffert R IEEE Trans Med Imaging; 1986; 5(3):152-61. PubMed ID: 18244001 [TBL] [Abstract][Full Text] [Related]
37. Generation of non-Rayleigh speckle distributions using marked regularity models. Cramblitt RM; Parker KJ IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(4):867-74. PubMed ID: 18238490 [TBL] [Abstract][Full Text] [Related]
38. A general statistical model for ultrasonic backscattering from tissues. Mohana Shankar P IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(3):727-36. PubMed ID: 18238602 [TBL] [Abstract][Full Text] [Related]
39. Modeling and analysis of ultrasound backscattering by spherical aggregates and rouleaux of red blood cells. Teh BG; Cloutier G IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(4):1025-35. PubMed ID: 18238637 [TBL] [Abstract][Full Text] [Related]
40. Speckle reduction in ultrasonic images through a maximum likelihood based adaptive filter. Shankar PM Phys Med Biol; 2006 Nov; 51(21):5591-602. PubMed ID: 17047272 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]