These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

75 related articles for article (PubMed ID: 18267690)

  • 1. Experimental study of focused ultrasonic beams reflected at a fluid-solid interface in the neighborhood of the Rayleigh angle.
    Matikas TE; Rousseau M; Gatignol P
    IEEE Trans Ultrason Ferroelectr Freq Control; 1992; 39(6):737-44. PubMed ID: 18267690
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative modeling of reflected ultrasonic bounded beams and a new estimate of the Schoch shift.
    Bouzidi Y; Schmitt DR
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Dec; 55(12):2661-73. PubMed ID: 19126490
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surfactant solutions and porous substrates: spreading and imbibition.
    Starov VM
    Adv Colloid Interface Sci; 2004 Nov; 111(1-2):3-27. PubMed ID: 15571660
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Harmonic generation of an obliquely incident ultrasonic wave in solid-solid contact interfaces.
    Nam T; Lee T; Kim C; Jhang KY; Kim N
    Ultrasonics; 2012 Aug; 52(6):778-83. PubMed ID: 22410490
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transient surface velocity measurements in a liquid by an active ultrasonic probe.
    Casula O; Royer D
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(3):760-7. PubMed ID: 18244227
    [TBL] [Abstract][Full Text] [Related]  

  • 6. DPSM technique for ultrasonic field modelling near fluid-solid interface.
    Banerjee S; Kundu T; Alnuaimi NA
    Ultrasonics; 2007 Jun; 46(3):235-50. PubMed ID: 17397891
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An algorithm for quantitatively modeling reflected ultrasonic bounded pulses and beams.
    Malehmir R; Kazemi N; Schmitt DR
    Ultrasonics; 2017 Sep; 80():15-21. PubMed ID: 28494229
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasonic diffraction grating spectroscopy and the measurement of particle size.
    Greenwood MS; Ahmed S
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1385-93. PubMed ID: 16824569
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigation of solid/solid interface waves with laser ultrasonics.
    Han QB; Qian ML; Wang H
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1323-7. PubMed ID: 16920174
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fringed sound fields and their interaction with liquid-solid interfaces.
    Declercq NF; Degrieck J; Leroy O
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1117-22. PubMed ID: 16793078
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of Rayleigh Wave Beams Using Angle Beam Wedge Transducers as the Transmitter and Receiver with Consideration of Beam Spreading.
    Zhang S; Li X; Jeong H
    Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28632183
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface roughness evaluation via ultrasonic scanning.
    Oh SJ; Shin YC; Furgason ES
    IEEE Trans Ultrason Ferroelectr Freq Control; 1994; 41(6):863-71. PubMed ID: 18263276
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bounded beam interaction with thin inclusions. Characterization by phase differences at Rayleigh angle incidence.
    Briers R; Leroy O; Shkerdin G
    J Acoust Soc Am; 2000 Oct; 108(4):1622-30. PubMed ID: 11051490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasonic field modeling by distributed point source method for different transducer boundary conditions.
    Yanagita T; Kundu T; Placko D
    J Acoust Soc Am; 2009 Nov; 126(5):2331-9. PubMed ID: 19894816
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fast beating null strip during the reflection of pulsed Gaussian beams incident at the Rayleigh angle.
    Declercq NF
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1447-51. PubMed ID: 16815510
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Liquid lens using acoustic radiation force.
    Koyama D; Isago R; Nakamura K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Mar; 58(3):596-602. PubMed ID: 21429850
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrasonic temperature imaging for guiding focused ultrasound surgery: effect of angle between imaging beam and therapy beam.
    Miller NR; Bograchev KM; Bamber JC
    Ultrasound Med Biol; 2005 Mar; 31(3):401-13. PubMed ID: 15749564
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Doppler diagnosis in peripheral arterial occlusive disease].
    Marshall M
    Herz; 1988 Dec; 13(6):358-71. PubMed ID: 3061917
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spin Hall effect of reflected light at the air-uniaxial crystal interface.
    Qin Y; Li Y; Feng X; Liu Z; He H; Xiao YF; Gong Q
    Opt Express; 2010 Aug; 18(16):16832-9. PubMed ID: 20721075
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Steady state spherically focused, circular aperture beam patterns.
    Goldstein A
    Ultrasound Med Biol; 2006 Oct; 32(10):1441-58. PubMed ID: 17045863
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.