BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

877 related articles for article (PubMed ID: 18271368)

  • 21. Changes in prosthetic screw stability because of misfit of implant-supported prostheses.
    al-Turki LE; Chai J; Lautenschlager EP; Hutten MC
    Int J Prosthodont; 2002; 15(1):38-42. PubMed ID: 11887597
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An in vitro evaluation of ZiReal abutments with hexagonal connection: in original state and following abutment preparation.
    Vigolo P; Fonzi F; Majzoub Z; Cordioli G
    Int J Oral Maxillofac Implants; 2005; 20(1):108-14. PubMed ID: 15747681
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Examination of the implant-abutment interface after fatigue testing.
    Cibirka RM; Nelson SK; Lang BR; Rueggeberg FA
    J Prosthet Dent; 2001 Mar; 85(3):268-75. PubMed ID: 11264934
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.
    Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D
    J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.
    Vigolo P; Majzoub Z; Cordioli G
    J Prosthet Dent; 2003 Feb; 89(2):186-92. PubMed ID: 12616240
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster.
    Wise M
    J Prosthet Dent; 2001 Nov; 86(5):532-8. PubMed ID: 11725282
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cement thickness at implant-supported single-tooth Lava assemblies: a scanning electron microscopic investigation.
    Apicella D; Veltri M; Chieffi N; Balleri P; Ferrari M
    Clin Oral Implants Res; 2010 Jul; 21(7):747-50. PubMed ID: 20636729
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The behavior of a zirconia or metal abutment on the implant-abutment interface during cyclic loading.
    Queiroz DA; Hagee N; Lee DJ; Zheng F
    J Prosthet Dent; 2020 Aug; 124(2):211-216. PubMed ID: 31810616
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns.
    Kim Y; Yamashita J; Shotwell JL; Chong KH; Wang HL
    J Prosthet Dent; 2006 Jun; 95(6):450-5. PubMed ID: 16765158
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Deformation of implant abutments after framework connection using strain gauges.
    Hollweg H; Jacques LB; da Silva Moura M; Bianco VC; Souza EA; Rubo JH
    J Oral Implantol; 2012 Apr; 38(2):125-32. PubMed ID: 22568468
    [TBL] [Abstract][Full Text] [Related]  

  • 31. On cobalt-chrome frameworks in implant dentistry.
    Hjalmarsson L
    Swed Dent J Suppl; 2009; (201):3-83. PubMed ID: 20143574
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The effect of engaging the screw access channel of an implant abutment with a cement-retained restoration.
    Naik S; Tredwin CJ; Nesbit M; Setchell DJ; Moles DR
    J Prosthodont; 2009 Apr; 18(3):245-8. PubMed ID: 19141047
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface.
    do Nascimento C; Pedrazzi V; Miani PK; Moreira LD; de Albuquerque RF
    Clin Oral Implants Res; 2009 Dec; 20(12):1394-7. PubMed ID: 19709063
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effects of abutment wall height, platform size, and screw access channel filling method on resistance to dislodgement of cement-retained, implant-supported restorations.
    Emms M; Tredwin CJ; Setchell DJ; Moles DR
    J Prosthodont; 2007; 16(1):3-9. PubMed ID: 17244301
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Validation of strain gauges as a method of measuring precision of fit of implant bars.
    Hegde R; Lemons JE; Broome JC; McCracken MS
    Implant Dent; 2009 Apr; 18(2):151-61. PubMed ID: 19359866
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of axial wall modification on the retention of cement-retained, implant-supported crowns.
    Tan KM; Masri R; Driscoll CF; Limkangwalmongkol P; Romberg E
    J Prosthet Dent; 2012 Feb; 107(2):80-5. PubMed ID: 22304741
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study.
    Di Felice R; Rappelli G; Camaioni E; Cattani M; Meyer JM; Belser UC
    Clin Oral Implants Res; 2007 Feb; 18(1):108-13. PubMed ID: 17224031
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cyclic loading of implant-supported prostheses: comparison of gaps at the prosthetic-abutment interface when cycled abutments are replaced with as-manufactured abutments.
    Hecker DM; Eckert SE; Choi YG
    J Prosthet Dent; 2006 Jan; 95(1):26-32. PubMed ID: 16399272
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Micromotion and dynamic fatigue properties of the dental implant-abutment interface.
    Gratton DG; Aquilino SA; Stanford CM
    J Prosthet Dent; 2001 Jan; 85(1):47-52. PubMed ID: 11174678
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Removal torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area.
    Squier RS; Psoter WJ; Taylor TD
    Int J Oral Maxillofac Implants; 2002; 17(1):24-7. PubMed ID: 11858571
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 44.