These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
235 related articles for article (PubMed ID: 18278486)
1. Reference standards to underpin the detection of steroid abuse by athletes. Mackay LG Anal Bioanal Chem; 2008 Jun; 391(3):911-3. PubMed ID: 18278486 [No Abstract] [Full Text] [Related]
2. Use of isotope ratio mass spectrometry to differentiate between endogenous steroids and synthetic homologues in cattle: a review. Janssens G; Courtheyn D; Mangelinckx S; Prévost S; Bichon E; Monteau F; De Poorter G; De Kimpe N; Le Bizec B Anal Chim Acta; 2013 Apr; 772():1-15. PubMed ID: 23540242 [TBL] [Abstract][Full Text] [Related]
3. Stable isotope ratio analysis in sports anti-doping. Cawley A Drug Test Anal; 2012 Dec; 4(12):891-2. PubMed ID: 23255318 [No Abstract] [Full Text] [Related]
4. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control. Cha E; Kim S; Kim HJ; Lee KM; Kim KH; Kwon OS; Lee J Drug Test Anal; 2015; 7(11-12):1040-9. PubMed ID: 26489966 [TBL] [Abstract][Full Text] [Related]
5. Metabolism and excretion of anabolic steroids in doping control--new steroids and new insights. Van Eenoo P; Delbeke FT J Steroid Biochem Mol Biol; 2006 Nov; 101(4-5):161-78. PubMed ID: 17000101 [TBL] [Abstract][Full Text] [Related]
6. Hydrogen isotope ratio mass spectrometry and high-resolution/high-accuracy mass spectrometry in metabolite identification studies: detecting target compounds for sports drug testing. Thevis M; Piper T; Horning S; Juchelka D; Schänzer W Rapid Commun Mass Spectrom; 2013 Sep; 27(17):1904-12. PubMed ID: 23939956 [TBL] [Abstract][Full Text] [Related]
7. External calibration in gas chromatography-combustion-isotope ratio mass spectrometry measurements of endogenous androgenic anabolic steroids in sports doping control. Kioussi MK; Angelis YS; Cawley AT; Koupparis M; Kazlauskas R; Brenna JT; Georgakopoulos CG J Chromatogr A; 2011 Aug; 1218(33):5675-82. PubMed ID: 21752385 [TBL] [Abstract][Full Text] [Related]
8. Test methods: anabolics. Saugy M; Cardis C; Robinson N; Schweizer C Baillieres Best Pract Res Clin Endocrinol Metab; 2000 Mar; 14(1):111-33. PubMed ID: 10932815 [TBL] [Abstract][Full Text] [Related]
9. Use of in vitro technologies to study phase II conjugation in equine sports drug surveillance. Taylor P; Scarth JP; Hillyer LL Bioanalysis; 2010 Dec; 2(12):1971-88. PubMed ID: 21110741 [TBL] [Abstract][Full Text] [Related]
10. GC-FID as a primary method for establishing the purity of organic CRMs used for drugs in sport analysis. King B; Westwood S Fresenius J Anal Chem; 2001 Jun; 370(2-3):194-9. PubMed ID: 11451235 [TBL] [Abstract][Full Text] [Related]
11. Floyd Landis: an unsafe conviction, regardless of the quality of the data. Faber NK Clin Chim Acta; 2010 Jan; 411(1-2):117-8. PubMed ID: 19822135 [No Abstract] [Full Text] [Related]
12. Validity of stable isotope data in doping control: perspectives and proposals. Flenker U; Geppert LN; Ickstadt K Drug Test Anal; 2012 Dec; 4(12):934-41. PubMed ID: 22972686 [TBL] [Abstract][Full Text] [Related]
13. Application of fast gas chromatography/mass spectrometry for the rapid screening of synthetic anabolic steroids and other drugs in anti-doping analysis. Mazzarino M; Orengia M; Botrè F Rapid Commun Mass Spectrom; 2007; 21(24):4117-24. PubMed ID: 18022961 [TBL] [Abstract][Full Text] [Related]
14. Determination of urinary steroid sulfate metabolites using ion paired extraction. Cawley AT; Kazlauskas R; Trout GJ; George AV J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Oct; 825(1):1-10. PubMed ID: 16154518 [TBL] [Abstract][Full Text] [Related]
16. Mass spectrometry in sports drug testing: Structure characterization and analytical assays. Thevis M; Schänzer W Mass Spectrom Rev; 2007; 26(1):79-107. PubMed ID: 16888758 [TBL] [Abstract][Full Text] [Related]
17. Examination of the kinetic isotopic effect to the acetylation derivatization for the gas chromatographic-combustion-isotope ratio mass spectrometric doping control analysis of endogenous steroids. Angelis YS; Kioussi MK; Kiousi P; Brenna JT; Georgakopoulos CG Drug Test Anal; 2012 Dec; 4(12):923-7. PubMed ID: 22374794 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of World Anti-Doping Agency criteria for anabolic agent analysis by using comprehensive two-dimensional gas chromatography-mass spectrometry. Mitrevski BS; Wilairat P; Marriott PJ Anal Bioanal Chem; 2010 Apr; 396(7):2503-11. PubMed ID: 20091298 [TBL] [Abstract][Full Text] [Related]
19. Automated and sensitive determination of four anabolic androgenic steroids in urine by online turbulent flow solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry: a novel approach for clinical monitoring and doping control. Guo F; Shao J; Liu Q; Shi JB; Jiang GB Talanta; 2014 Jul; 125():432-8. PubMed ID: 24840468 [TBL] [Abstract][Full Text] [Related]
20. A confirmatory method for detection of a banned substance: the validation experience of a routine EU laboratory. Galarini R; Piersanti A; Falasca S; Salamida S; Fioroni L Anal Chim Acta; 2007 Mar; 586(1-2):130-6. PubMed ID: 17386704 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]