BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 18278716)

  • 1. Intestinal bowel perforation and bacterial peritonitis secondary to migrated biliary and pancreatic stents.
    Seerden TC; Moreels TG; Salgado RA; Francque SM; Michielsen PP; Parizel PM; Pelckmans PA
    Endoscopy; 2008 Sep; 40 Suppl 2():E25. PubMed ID: 18278716
    [No Abstract]   [Full Text] [Related]  

  • 2. Cut and Paste: Endoscopic Management of a Perforating Biliary Stent Utilizing Scissors and Clips.
    Barakat MT; Kothari S; Banerjee S
    Dig Dis Sci; 2018 Sep; 63(9):2202-2205. PubMed ID: 29127608
    [No Abstract]   [Full Text] [Related]  

  • 3. Duodenal perforation due to plastic stent migration successfully treated by endoscopy.
    Prachayakul V; Aswakul P; Kachintorn U
    Gastrointest Endosc; 2012 Jun; 75(6):1265-6. PubMed ID: 22440332
    [No Abstract]   [Full Text] [Related]  

  • 4. Clip closure of a duodenal perforation secondary to a biliary stent.
    Rosés LL; Ramirez AG; Seco AL; Blanco ES; Alonso DI; Avila S; Lopez BU
    Gastrointest Endosc; 2000 Apr; 51(4 Pt 1):487-9. PubMed ID: 10744829
    [No Abstract]   [Full Text] [Related]  

  • 5. Cholangiopancreatography troubleshooting: the usefulness of endoscopic retrieval of migrated biliary and pancreatic stents.
    Sakai Y; Tsuyuguchi T; Ishihara T; Sugiyama H; Eto R; Fujimoto T; Yasui S; Tamura R; Togo S; Tada M; Yokosuka O
    Hepatobiliary Pancreat Dis Int; 2009 Dec; 8(6):632-7. PubMed ID: 20007082
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A case of duodenal perforation caused by biliary plastic stent treated with approximation using endoclip and detachable snare].
    Nam HS; Kim GH; Kim DU; Choi MK; Yi YS; Hwang JM; Kim S
    Korean J Gastroenterol; 2011 Feb; 57(2):129-33. PubMed ID: 21350325
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Early retroduodenal perforation following endoscopic internal biliary drainage.
    Coppola R; Masetti R; Riccioni ME; Ciletti S; De Franco A; Detweiler M; Magistrelli P; Picciocchi A
    Endoscopy; 1993 Mar; 25(3):255-6. PubMed ID: 8519251
    [No Abstract]   [Full Text] [Related]  

  • 8. A case of colonic perforation from biliary stent.
    Aryal KR; Sherlock DJ
    Endoscopy; 2008 Sep; 40 Suppl 2():E54. PubMed ID: 18633917
    [No Abstract]   [Full Text] [Related]  

  • 9. Endoscopic retrieval of a proximally migrated pancreatic stent.
    Kudo Y; Kurita A; Yazumi S
    Dig Endosc; 2015 Nov; 27(7):777. PubMed ID: 26202598
    [No Abstract]   [Full Text] [Related]  

  • 10. [The penetration of a bile duct metal stent into the duodenal bulb as a late complication of combined stent/radiotherapy in Klatskin's tumor].
    Wingen M; Nguyen NH; Vorwerk D; Andreopoulos D
    Rofo; 1997 Jan; 166(1):75-7. PubMed ID: 9072110
    [No Abstract]   [Full Text] [Related]  

  • 11. Duodenal perforation secondary to placement of a biliary endoprosthesis diagnosed by multislice computed tomography.
    Novacek G; Hörmann M; Puig S; Herbst F; Püspök A; Schöfl R
    Endoscopy; 2002 Apr; 34(4):351. PubMed ID: 11932800
    [No Abstract]   [Full Text] [Related]  

  • 12. Endoscopic retrieval of a proximally migrated biliary stent within the gallbladder lumen.
    Gleeson FC; Petersen BT; Levy MJ
    Endoscopy; 2008 Sep; 40 Suppl 2():E3-4. PubMed ID: 18278724
    [No Abstract]   [Full Text] [Related]  

  • 13. Migration of endoscopic biliary stent and small bowel perforation within an incisional hernia.
    Akimboye F; Lloyd T; Hobson S; Garcea G
    Surg Laparosc Endosc Percutan Tech; 2006 Feb; 16(1):39-40. PubMed ID: 16552378
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Colonic Perforation Secondary to Retained Biliary Stent.
    Chou ND; Burbridge RA; Jowell PS
    Am J Gastroenterol; 2017 Jan; 112(1):13. PubMed ID: 28050041
    [No Abstract]   [Full Text] [Related]  

  • 15. Migrated biliary stent predisposing to fatal ERCP-related perforation of the duodenum.
    Paikos D; Gatopoulou A; Moschos J; Soufleris K; Tarpagos A; Katsos I
    J Gastrointestin Liver Dis; 2006 Dec; 15(4):387-8. PubMed ID: 17205153
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Migration of plastic biliary stents and endoscopic retrieval: an experience of three referral centers.
    Katsinelos P; Kountouras J; Paroutoglou G; Chatzimavroudis G; Paikos D; Zavos C; Karakousis K; Gelas G; Tzilves D
    Surg Laparosc Endosc Percutan Tech; 2009 Jun; 19(3):217-21. PubMed ID: 19542849
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intestinal perforation in a parastomal hernia by a migrated plastic biliary stent.
    Levey JM
    Surg Endosc; 2002 Nov; 16(11):1636-7. PubMed ID: 12085152
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of a pre-positioned guide wire to aid in the removal of a pancreatic duct stent that had migrated further into the duct.
    Pan Y; Zhao L; Liu Z; Zhang R; Hui N; Fan D; Guo X
    Endoscopy; 2011; 43 Suppl 2 UCTN():E315-6. PubMed ID: 22020703
    [No Abstract]   [Full Text] [Related]  

  • 19. Duodenal perforation caused by a cutting-induced sharp-edged plastic stent (with video).
    Oh HC; Kim SW; Do JH; Kim G
    Gastrointest Endosc; 2012 Nov; 76(5):1050; discussion 1050-1. PubMed ID: 22902144
    [No Abstract]   [Full Text] [Related]  

  • 20. A devastating complication: duodenal perforation due to biliary stent migration.
    Lo CH; Chung S; Bohmer RD
    Surg Laparosc Endosc Percutan Tech; 2008 Dec; 18(6):608-10. PubMed ID: 19098671
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.