BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 18281219)

  • 1. Antibacterial effects of electrically activated vertebral implants.
    Secinti KD; Ayten M; Kahilogullari G; Kaygusuz G; Ugur HC; Attar A
    J Clin Neurosci; 2008 Apr; 15(4):434-9. PubMed ID: 18281219
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nanoparticle silver ion coatings inhibit biofilm formation on titanium implants.
    Secinti KD; Özalp H; Attar A; Sargon MF
    J Clin Neurosci; 2011 Mar; 18(3):391-5. PubMed ID: 21256031
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo efficacy of antimicrobial-coated fabric from prosthetic heart valve sewing rings.
    Darouiche RO; Meade R; Mansouri M; Raad II
    J Heart Valve Dis; 1998 Nov; 7(6):639-46. PubMed ID: 9870198
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prophylaxis of infection and effects on osseointegration using a tobramycin-periapatite coating on titanium implants--an experimental study in the rabbit.
    Moojen DJ; Vogely HC; Fleer A; Nikkels PG; Higham PA; Verbout AJ; Castelein RM; Dhert WJ
    J Orthop Res; 2009 Jun; 27(6):710-6. PubMed ID: 19025776
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation and comparison of the antimicrobial efficacy of teicoplanin- and clindamycin-coated titanium implants: an experimental study.
    Aykut S; Oztürk A; Ozkan Y; Yanik K; Ilman AA; Ozdemir RM
    J Bone Joint Surg Br; 2010 Jan; 92(1):159-63. PubMed ID: 20044697
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Silver ion doped ceramic nano-powder coated nails prevent infection in open fractures: In vivo study.
    Kose N; Çaylak R; Pekşen C; Kiremitçi A; Burukoglu D; Koparal S; Doğan A
    Injury; 2016 Feb; 47(2):320-4. PubMed ID: 26589596
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A silver ion-doped calcium phosphate-based ceramic nanopowder-coated prosthesis increased infection resistance.
    Kose N; Otuzbir A; Pekşen C; Kiremitçi A; Doğan A
    Clin Orthop Relat Res; 2013 Aug; 471(8):2532-9. PubMed ID: 23463287
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hydroxyapatite dip coated and uncoated titanium poly-axial pedicle screws: an in vivo bovine model.
    Yildirim OS; Aksakal B; Hanyaloglu SC; Erdogan F; Okur A
    Spine (Phila Pa 1976); 2006 Apr; 31(8):E215-20. PubMed ID: 16622364
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Antimicrobial Effect of Polymer-Based Silver Nanoparticle Coated Pedicle Screws: Experimental Research on Biofilm Inhibition in Rabbits.
    Hazer DB; Sakar M; Dere Y; Altinkanat G; Ziyal MI; Hazer B
    Spine (Phila Pa 1976); 2016 Mar; 41(6):E323-9. PubMed ID: 26571170
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect on infection resistance of a local antiseptic and antibiotic coating on osteosynthesis implants: an in vitro and in vivo study.
    Kälicke T; Schierholz J; Schlegel U; Frangen TM; Köller M; Printzen G; Seybold D; Klöckner S; Muhr G; Arens S
    J Orthop Res; 2006 Aug; 24(8):1622-40. PubMed ID: 16779814
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Activation of antibacterial silver coatings on surgical implants by direct current: preliminary studies in rabbits.
    Colmano G; Edwards SS; Barranco SD
    Am J Vet Res; 1980 Jun; 41(6):964-6. PubMed ID: 7436092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy of bioabsorbable antibiotic containing bone screw in the prevention of biomaterial-related infection due to Staphylococcus aureus.
    Mäkinen TJ; Veiranto M; Knuuti J; Jalava J; Törmälä P; Aro HT
    Bone; 2005 Feb; 36(2):292-9. PubMed ID: 15780955
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of collagen silver-coated polyester and rifampin-soaked vascular grafts to resist infection from MRSA and Escherichia coli in a dog model.
    Schneider F; O'Connor S; Becquemin JP
    Ann Vasc Surg; 2008 Nov; 22(6):815-21. PubMed ID: 18835516
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gentamicin coating of nanotubular anodized titanium implant reduces implant-related osteomyelitis and enhances bone biocompatibility in rabbits.
    Liu D; He C; Liu Z; Xu W
    Int J Nanomedicine; 2017; 12():5461-5471. PubMed ID: 28814863
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pedicle screw surface coatings improve fixation in nonfusion spinal constructs.
    Upasani VV; Farnsworth CL; Tomlinson T; Chambers RC; Tsutsui S; Slivka MA; Mahar AT; Newton PO
    Spine (Phila Pa 1976); 2009 Feb; 34(4):335-43. PubMed ID: 19182704
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel animal model for studying the molecular mechanisms of bacterial adhesion to bone-implanted metallic devices: role of fibronectin in Staphylococcus aureus adhesion.
    Fischer B; Vaudaux P; Magnin M; el Mestikawy Y; Proctor RA; Lew DP; Vasey H
    J Orthop Res; 1996 Nov; 14(6):914-20. PubMed ID: 8982134
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Alveolar ridge augmentation using implants coated with recombinant human bone morphogenetic protein-2: histologic observations.
    Wikesjö UM; Qahash M; Polimeni G; Susin C; Shanaman RH; Rohrer MD; Wozney JM; Hall J
    J Clin Periodontol; 2008 Nov; 35(11):1001-10. PubMed ID: 18976397
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Titanium-coated silicone is not effective for preventing graft infection].
    Hernandez-Richter T; Wittmann B; Wittmann F; Loehe F; Rentsch M; Mayr S; Jauch KW; Angele MK
    Zentralbl Chir; 2007 Feb; 132(1):32-7. PubMed ID: 17304433
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Antimicrobial coating agents: can biofilm formation on a breast implant be prevented?
    van Heerden J; Turner M; Hoffmann D; Moolman J
    J Plast Reconstr Aesthet Surg; 2009 May; 62(5):610-7. PubMed ID: 18359675
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Adhesion of Staphylococcus to orthopaedic metals, an in vivo study.
    Sheehan E; McKenna J; Mulhall KJ; Marks P; McCormack D
    J Orthop Res; 2004 Jan; 22(1):39-43. PubMed ID: 14656657
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.