227 related articles for article (PubMed ID: 18287452)
41. Saline flush effect for enhancement of aorta and coronary arteries at multidetector CT coronary angiography.
Kim DJ; Kim TH; Kim SJ; Kim DP; Oh CS; Ryu YH; Kim YJ; Choi BW
Radiology; 2008 Jan; 246(1):110-5. PubMed ID: 18096532
[TBL] [Abstract][Full Text] [Related]
42. Comparison between one-route and two-route injection for liver and aortic enhancement using MDCT.
Okada M; Murakami T; Kumano S; Imaoka I; Shimono T; Ashikaga R; Hosono M
AJR Am J Roentgenol; 2008 Jun; 190(6):W323-6. PubMed ID: 18492873
[TBL] [Abstract][Full Text] [Related]
43. Automated attenuation-based selection of tube voltage and tube current for coronary CT angiography: reduction of radiation exposure versus a BMI-based strategy with an expert investigator.
Layritz C; Muschiol G; Flohr T; Bietau C; Marwan M; Schuhbaeck A; Schmid J; Ropers D; Achenbach S; Pflederer T
J Cardiovasc Comput Tomogr; 2013; 7(5):303-10. PubMed ID: 24268117
[TBL] [Abstract][Full Text] [Related]
44. Determination of height, weight, body mass index, and body surface area with a single abdominal CT image.
Geraghty EM; Boone JM
Radiology; 2003 Sep; 228(3):857-63. PubMed ID: 12881576
[TBL] [Abstract][Full Text] [Related]
45. Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser.
Cademartiri F; Mollet N; van der Lugt A; Nieman K; Pattynama PM; de Feyter PJ; Krestin GP
Eur Radiol; 2004 Feb; 14(2):178-83. PubMed ID: 14689227
[TBL] [Abstract][Full Text] [Related]
46. A comparison of the efficacy and safety of iopamidol-370 and iodixanol-320 in patients undergoing multidetector-row computed tomography.
Sahani DV; Soulez G; Chen KM; Lepanto L; Xu JR; Nelson RC; Grazioli L; Vanzulli A; Heiken JP;
Invest Radiol; 2007 Dec; 42(12):856-61. PubMed ID: 18007158
[TBL] [Abstract][Full Text] [Related]
47. Body surface area in normal-weight, overweight, and obese adults. A comparison study.
Verbraecken J; Van de Heyning P; De Backer W; Van Gaal L
Metabolism; 2006 Apr; 55(4):515-24. PubMed ID: 16546483
[TBL] [Abstract][Full Text] [Related]
48. Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method.
Bae KT; Tran HQ; Heiken JP
Radiology; 2004 Jun; 231(3):732-6. PubMed ID: 15163812
[TBL] [Abstract][Full Text] [Related]
49. CT pulmonary angiography and CT venography: factors associated with vessel enhancement.
Arakawa H; Kohno T; Hiki T; Kaji Y
AJR Am J Roentgenol; 2007 Jul; 189(1):156-61. PubMed ID: 17579166
[TBL] [Abstract][Full Text] [Related]
50. Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.
Fleischmann D; Rubin GD; Bankier AA; Hittmair K
Radiology; 2000 Feb; 214(2):363-71. PubMed ID: 10671582
[TBL] [Abstract][Full Text] [Related]
51. Four- and eight-channel aortoiliac CT angiography: a comparative study.
Karcaaltincaba M; Foley D
Cardiovasc Intervent Radiol; 2005; 28(2):169-72. PubMed ID: 15719187
[TBL] [Abstract][Full Text] [Related]
52. Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest.
Johnson TR; Nikolaou K; Wintersperger BJ; Fink C; Rist C; Leber AW; Knez A; Reiser MF; Becker CR
J Comput Assist Tomogr; 2007; 31(2):265-71. PubMed ID: 17414765
[TBL] [Abstract][Full Text] [Related]
53. Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight?
Kondo H; Kanematsu M; Goshima S; Watanabe H; Kawada H; Moriyama N; Bae KT
Eur Radiol; 2013 Jul; 23(7):1855-61. PubMed ID: 23508277
[TBL] [Abstract][Full Text] [Related]
54. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: influence on quantitative and clinical assessment in combined PET/CT.
Verburg FA; Apitzsch J; Lensing C; Kuhl CK; Pietsch H; Mottaghy FM; Behrendt FF
Eur J Radiol; 2013 Dec; 82(12):2348-52. PubMed ID: 24113432
[TBL] [Abstract][Full Text] [Related]
55. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.
Kirchner J; Kickuth R; Laufer U; Noack M; Liermann D
Clin Radiol; 2000 May; 55(5):368-73. PubMed ID: 10816403
[TBL] [Abstract][Full Text] [Related]
56. Feasibility of a low concentration test bolus in CT angiography.
Nijhof WH; Jansen MM; Jager GJ; Slump CH; Rutten MJ
Clin Radiol; 2016 Dec; 71(12):1313.e1-1313.e4. PubMed ID: 27720180
[TBL] [Abstract][Full Text] [Related]
57. Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation.
Yamamuro M; Tadamura E; Kanao S; Wu YW; Tambara K; Komeda M; Toma M; Kimura T; Kita T; Togashi K
J Comput Assist Tomogr; 2007; 31(2):272-80. PubMed ID: 17414766
[TBL] [Abstract][Full Text] [Related]
58. CT angiography of the neck: value of contrast medium dose reduction with low tube voltage and high tube current in a 64-detector row CT.
Xia W; Wu JT; Yin XR; Wang ZJ; Wu HT
Clin Radiol; 2014 Apr; 69(4):e183-9. PubMed ID: 24503560
[TBL] [Abstract][Full Text] [Related]
59. [Optimization of contrast injection protocol for coronary CTA: adjustment of injection iodine volume on test bolus parameters and patients' sex and BSA].
Akiyama N; Nakamura Y
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2009 Aug; 65(8):1073-80. PubMed ID: 19721316
[TBL] [Abstract][Full Text] [Related]
60. A non-invasive cardiac output measurement as an alternative to the test bolus technique during CT angiography.
Nijhof WH; Hilbink M; Jager GJ; Slump CH; Rutten MJ
Clin Radiol; 2016 Sep; 71(9):940.e1-5. PubMed ID: 27076253
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]