BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

279 related articles for article (PubMed ID: 18288669)

  • 1. Integrated isotachophoretic stacking and gel electrophoresis on a plastic substrate and variations in detection dynamic range.
    Lin CC; Hsu BK; Chen SH
    Electrophoresis; 2008 Mar; 29(6):1228-36. PubMed ID: 18288669
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On-line isotachophoretic preconcentration and gel electrophoretic separation of sodium dodecyl sulfate-proteins on a microchip.
    Huang H; Xu F; Dai Z; Lin B
    Electrophoresis; 2005 Jun; 26(11):2254-60. PubMed ID: 15852349
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid and efficient isotachophoretic preconcentration in free solution coupled with gel electrophoresis separation on a microchip using a negative pressure sampling technique.
    Qi LY; Yin XF; Liu JH
    J Chromatogr A; 2009 May; 1216(20):4510-6. PubMed ID: 19328490
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Isotachophoresis preconcentration integrated microfluidic chip for highly sensitive genotyping of the hepatitis B virus.
    Liu D; Shi M; Huang H; Long Z; Zhou X; Qin J; Lin B
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Nov; 844(1):32-8. PubMed ID: 16899416
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simple and sensitive transient ITP method for on-chip analysis of PCR samples.
    Wang L; Liu D; Chen H; Zhou X
    Electrophoresis; 2008 Dec; 29(24):4976-83. PubMed ID: 19130577
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Semihydrodynamic injection for high salt stacking and sweeping on microchip electrophoresis and its application for the analysis of estrogen and estrogen binding.
    Chen CC; Yen SF; Makamba H; Li CW; Tsai ML; Chen SH
    Anal Chem; 2007 Jan; 79(1):195-201. PubMed ID: 17194139
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Trace analysis of DNA: preconcentration, separation, and electrochemical detection in microchip electrophoresis using Au nanoparticles.
    Shiddiky MJ; Shim YB
    Anal Chem; 2007 May; 79(10):3724-33. PubMed ID: 17428034
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Integrated isotachophoretic preconcentration with zone electrophoresis separation on a quartz microchip for UV detection of flavonoids.
    Ma B; Zhou X; Wang G; Huang H; Dai Z; Qin J; Lin B
    Electrophoresis; 2006 Dec; 27(24):4904-9. PubMed ID: 17117378
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Recent progress of online sample preconcentration techniques in microchip electrophoresis.
    Sueyoshi K; Kitagawa F; Otsuka K
    J Sep Sci; 2008 Aug; 31(14):2650-66. PubMed ID: 18693308
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Separation of proteins by zone electrophoresis on-line coupled with isotachophoresis on a column-coupling chip with conductivity detection.
    Olvecká E; Kaniansky D; Pollák B; Stanislawski B
    Electrophoresis; 2004 Nov; 25(21-22):3865-74. PubMed ID: 15565671
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simplified transient isotachophoresis/capillary gel electrophoresis method for highly sensitive analysis of polymerase chain reaction samples on a microchip with laser-induced fluorescence detection.
    Liu D; Ou Z; Xu M; Wang L
    J Chromatogr A; 2008 Dec; 1214(1-2):165-70. PubMed ID: 18992883
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selective protein removal and desalting using microchip CE.
    Silvertand LH; Machtejevas E; Hendriks R; Unger KK; van Bennekom WP; de Jong GJ
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jul; 839(1-2):68-73. PubMed ID: 16600700
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro contactor based on isotachophoretic sample transport.
    Goet G; Baier T; Hardt S
    Lab Chip; 2009 Dec; 9(24):3586-93. PubMed ID: 20024040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Controlling data quality and reproducibility of a high-sensitivity immunoassay using isotachophoresis in a microchip.
    Park CC; Kazakova I; Kawabata T; Spaid M; Chien RL; Wada HG; Satomura S
    Anal Chem; 2008 Feb; 80(3):808-14. PubMed ID: 18173249
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Integration of continuous-flow sampling with microchip electrophoresis using poly(dimethylsiloxane)-based valves in a reversibly sealed device.
    Li MW; Martin RS
    Electrophoresis; 2007 Jul; 28(14):2478-88. PubMed ID: 17577199
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On-column conductivity detection in capillary-chip electrophoresis.
    Wu ZY; Fang F; Josserand J; Girault HH
    Electrophoresis; 2007 Dec; 28(24):4612-9. PubMed ID: 18008311
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On-chip millionfold sample stacking using transient isotachophoresis.
    Jung B; Bharadwaj R; Santiago JG
    Anal Chem; 2006 Apr; 78(7):2319-27. PubMed ID: 16579615
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Isotachophoresis of proteins in a networked microfluidic chip: experiment and 2-D simulation.
    Cui H; Dutta P; Ivory CF
    Electrophoresis; 2007 Apr; 28(7):1138-45. PubMed ID: 17330226
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microchip DNA electrophoresis with automated whole-gel scanning detection.
    Lo RC; Ugaz VM
    Lab Chip; 2008 Dec; 8(12):2135-45. PubMed ID: 19023477
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection.
    Huang FC; Liao CS; Lee GB
    Electrophoresis; 2006 Aug; 27(16):3297-305. PubMed ID: 16865670
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.