These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 18294244)

  • 21. COBAS Amplicor: an automated PCR system for detection of C. trachomatis and N. gonorrhoeae.
    Van der Pol B
    Expert Rev Mol Diagn; 2002 Jul; 2(4):379-89. PubMed ID: 12138503
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance of strand displacement amplification assay in the detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
    Fontana C; Favaro M; Cicchetti O; Minelli S; Pistoia ES; Favalli C
    Jpn J Infect Dis; 2005 Oct; 58(5):283-8. PubMed ID: 16249622
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Multicenter evaluation of AMPLICOR and automated COBAS AMPLICOR CT/NG tests for Neisseria gonorrhoeae.
    Martin DH; Cammarata C; Van Der Pol B; Jones RB; Quinn TC; Gaydos CA; Crotchfelt K; Schachter J; Moncada J; Jungkind D; Turner B; Peyton C
    J Clin Microbiol; 2000 Oct; 38(10):3544-9. PubMed ID: 11015361
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A duplex Neisseria gonorrhoeae real-time polymerase chain reaction assay targeting the gonococcal porA pseudogene and multicopy opa genes.
    Goire N; Nissen MD; LeCornec GM; Sloots TP; Whiley DM
    Diagn Microbiol Infect Dis; 2008 May; 61(1):6-12. PubMed ID: 18248938
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A real-time PCR assay for the detection of Neisseria gonorrhoeae in genital and extragenital specimens.
    Whiley DM; Buda PP; Freeman K; Pattle NI; Bates J; Sloots TP
    Diagn Microbiol Infect Dis; 2005 May; 52(1):1-5. PubMed ID: 15878435
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Analytical specificity and sensitivity of the novel dual-target GeneProof Neisseria gonorrhoeae PCR kit for detection of N. gonorrhoeae.
    Golparian D; Hellmark B; Unemo M
    APMIS; 2015 Nov; 123(11):955-8. PubMed ID: 26332192
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Screening tests for Chlamydia trachomatis or Neisseria gonorrhoeae using the cobas 4800 PCR system do not require a second test to confirm: an audit of patients issued with equivocal results at a sexual health clinic in the Northwest of England, U.K.
    Hopkins MJ; Smith G; Hart IJ; Alloba F
    Sex Transm Infect; 2012 Nov; 88(7):495-7. PubMed ID: 22661631
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Design of a multiplex PCR assay for the simultaneous detection and confirmation of Neisseria gonorrhoeae.
    O'Callaghan I; Corcoran D; Lucey B
    J Clin Pathol; 2010 May; 63(5):431-3. PubMed ID: 20360139
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of microscopy, culture and in-house PCR and NASBA assays for diagnosis of Neisseria gonorrhoeae in Russia.
    Shipitsyna E; Guschin A; Maximova A; Tseslyuk M; Savicheva A; Sokolovsky E; Shipulin G; Domeika M; Unemo M
    APMIS; 2008 Feb; 116(2):133-8. PubMed ID: 18321364
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Abilities of APTIMA, AMPLICOR, and ProbeTec assays to detect Chlamydia trachomatis and Neisseria gonorrhoeae in PreservCyt ThinPrep Liquid-based Pap samples.
    Chernesky M; Jang D; Portillo E; Chong S; Smieja M; Luinstra K; Petrich A; Macritchie C; Ewert R; Hayhoe B; Sarabia A; Thompson F
    J Clin Microbiol; 2007 Aug; 45(8):2355-8. PubMed ID: 17537943
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of replacing the existing diagnostic strategy for Neisseria gonorrhoeae and Chlamydia trachomatis infections with sole molecular testing of urine specimens in a sexually transmitted infection clinic setting.
    Ho MK; Lo JY; Lo AC; Cheng FK; Chan FK
    Sex Transm Infect; 2009 Sep; 85(5):322-5. PubMed ID: 19406739
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of the Roche Cobas Amplicor polymerase chain reaction test for gonorrhoea in a low prevalence area.
    Bhaduri S; Howells V
    Int J STD AIDS; 2007 Nov; 18(11):796-7. PubMed ID: 18005519
    [No Abstract]   [Full Text] [Related]  

  • 33. Enhancing the specificity of the COBAS AMPLICOR CT/NG test for Neisseria gonorrhoeae by retesting specimens with equivocal results.
    Van Der Pol B; Martin DH; Schachter J; Quinn TC; Gaydos CA; Jones RB; Crotchfelt K; Moncada J; Jungkind D; Turner B; Peyton C; Kelly JF; Weiss JB; Rosenstraus M
    J Clin Microbiol; 2001 Sep; 39(9):3092-8. PubMed ID: 11526134
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Comparison of Tosoh TRCRapid M.TB assay by transcription-reverse transcription concerted reaction (TRC) with Roche COBAS AMPLICOR assay by PCR and with culture for detection of Mycobacterium tuberculosis complex].
    Takeda H; Hirose H; Ogura A; Kato Y; Sugiyama Y; Harada H; Fukuno Y; Yamamura T; Miyajima E
    Rinsho Byori; 2008 Apr; 56(4):277-82. PubMed ID: 18516961
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of an opa gene-based nucleic acid amplification test for detection of Neisseria gonorrhoeae in urogenital samples in North India.
    Verma R; Sood S; Bala M; Mahajan N; Kapil A; Sharma VK; Pandey RM; Samantaray JC
    Epidemiol Infect; 2012 Nov; 140(11):2110-6. PubMed ID: 22244259
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Multicenter validation of the cppB gene as a PCR target for detection of Neisseria gonorrhoeae.
    Bruisten SM; Noordhoek GT; van den Brule AJ; Duim B; Boel CH; El-Faouzi K; du Maine R; Mulder S; Luijt D; Schirm J
    J Clin Microbiol; 2004 Sep; 42(9):4332-4. PubMed ID: 15365038
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Diagnostic implications of 16S ribosomal assay for gonorrhoea.
    Verma R; Sood S; Bala M; Kapil A; Das BK; Sharma VK; Samantaray JC
    Sex Transm Infect; 2010 Nov; 86(6):461-4. PubMed ID: 20542960
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of an automated extraction method for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by Cobas Amplicor PCR from different sample materials.
    Geertsen R; Friderich P; Dobec M; Emler S
    Scand J Infect Dis; 2007; 39(5):405-8. PubMed ID: 17464862
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Use of a reliable PCR assay for the detection of Neisseria gonorrhoeae in Peruvian patients.
    Mayta H; Calderon M; Taverna J; Montenegro S; Balqui J; Campos K; Tuero I; Arevalo J; Vivar A; Gilman RH
    Clin Microbiol Infect; 2006 Aug; 12(8):809-12. PubMed ID: 16842581
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Validation of the Roche COBAS Amplicor system for Chlamydia trachomatis.
    Matthews-Greer JM; McRae KL; LaHaye EB; Jamison RM
    Clin Lab Sci; 2001; 14(2):82-4. PubMed ID: 15625979
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.