These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 18301475)

  • 1. Field calibration unit for ultraviolet spectroradiometers.
    Early EA; Thompson EA; Disterhoft P
    Appl Opt; 1998 Oct; 37(28):6664-70. PubMed ID: 18301475
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The 1996 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers.
    Early E; Thompson A; Johnson C; DeLuisi J; Disterhoft P; Wardle D; Wu E; Mou W; Ehramjian J; Tusson J; Mestechkina T; Beaubian M; Gibson J; Hayes D
    J Res Natl Inst Stand Technol; 1998; 103(5):449-482. PubMed ID: 28009358
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The 1995 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers.
    Early E; Thompson A; Johnson C; DeLuisi J; Disterhoft P; Wardle D; Wu E; Mou W; Sun Y; Lucas T; Mestechkina T; Harrison L; Berndt J; Hayes DS
    J Res Natl Inst Stand Technol; 1998; 103(1):15-62. PubMed ID: 28009371
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of spectral irradiance standards used to calibrate shortwave radiometers and spectroradiometers.
    Kiedron PW; Michalsky JJ; Berndt JL; Harrison LC
    Appl Opt; 1999 Apr; 38(12):2432-9. PubMed ID: 18319808
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The 1994 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers.
    Thompson A; Early EA; DeLuisi J; Disterhoft P; Wardle D; Kerr J; Rives J; Sun Y; Lucas T; Mestechkina T; Neale P
    J Res Natl Inst Stand Technol; 1997; 102(3):279-322. PubMed ID: 27805148
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The 1997 North American Interagency Intercomparison of Ultraviolet Spectroradiometers Including Narrowband Filter Radiometers.
    Lantz K; Disterhoft P; Early E; Thompson A; DeLuisi J; Berndt J; Harrison L; Kiedron P; Ehramjian J; Bernhard G; Cabasug L; Robertson J; Mou W; Taylor T; Slusser J; Bigelow D; Durham B; Janson G; Hayes D; Beaubien M; Beaubien A
    J Res Natl Inst Stand Technol; 2002; 107(1):19-62. PubMed ID: 27446717
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Traceability of solar UV measurements using the Qasume reference spectroradiometer.
    Hülsen G; Gröbner J; Nevas S; Sperfeld P; Egli L; Porrovecchio G; Smid M
    Appl Opt; 2016 Sep; 55(26):7265-75. PubMed ID: 27661362
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Irradiance of Horizontal Quartz-Halogen Standard Lamps.
    Early EA; Thompson A
    J Res Natl Inst Stand Technol; 1996; 101(2):141-153. PubMed ID: 27805121
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intercomparison of indoor and outdoor spectral irradiance measurements between INTI and INMETRO.
    Ferreira da Silva T; Babaro JP; Zinzallari A; Jesiotr V
    Appl Opt; 2021 Jun; 60(17):5177-5185. PubMed ID: 34143082
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Facility for spectral irradiance and radiance responsivity calibrations using uniform sources.
    Brown SW; Eppeldauer GP; Lykke KR
    Appl Opt; 2006 Nov; 45(32):8218-37. PubMed ID: 17068565
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Traveling reference spectroradiometer for routine quality assurance of spectral solar ultraviolet irradiance measurements.
    Gröbner J; Schreder J; Kazadzis S; Bais AF; Blumthaler M; Görts P; Tax R; Koskela T; Seckmeyer G; Webb AR; Rembges D
    Appl Opt; 2005 Sep; 44(25):5321-31. PubMed ID: 16149356
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spectral Power and Irradiance Responsivity Calibration of InSb Working-Standard Radiometers.
    Eppeldauer G; Rácz M
    Appl Opt; 2000 Nov; 39(31):5739-44. PubMed ID: 18354571
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nonlinearity characterization of array spectroradiometers for the solar UV measurements.
    Pulli T; Nevas S; El Gawhary O; van den Berg S; Askola J; Kärhä P; Manoocheri F; Ikonen E
    Appl Opt; 2017 Apr; 56(11):3077-3086. PubMed ID: 28414366
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The measurement of solar ultraviolet radiation.
    Roy CR; Gies HP; Lugg DJ; Toomey S; Tomlinson DW
    Mutat Res; 1998 Nov; 422(1):7-14. PubMed ID: 9920423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology.
    Tsai BK
    J Res Natl Inst Stand Technol; 1997; 102(5):551-558. PubMed ID: 27805142
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer.
    Jauniskis L; Foukal P; Kochling H
    Appl Opt; 1992 Sep; 31(27):5838-43. PubMed ID: 20733776
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Field calibrations of a long-term UV dosimeter for aquatic UVB exposures.
    Schouten PW; Parisi AV; Turnbull DJ
    J Photochem Photobiol B; 2008 May; 91(2-3):108-16. PubMed ID: 18374597
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Research on absolute calibration of sun channel of sun photometer using laser raster scanning method].
    Xu WB; Li JJ; Zheng XB
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Jan; 33(1):255-60. PubMed ID: 23586268
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Usability of a Fourier transform spectroradiometer for absolute surface spectral solar UV irradiance measurements.
    Meindl P; Wähmer M; Monte C
    Opt Express; 2014 Oct; 22(21):25071-83. PubMed ID: 25401540
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experimental determination of the reference plane of shaped diffusers by solar ultraviolet measurements.
    Gröbner J; Blumthaler M
    Opt Lett; 2007 Jan; 32(1):80-2. PubMed ID: 17167590
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.