159 related articles for article (PubMed ID: 18303387)
1. The influence of central corneal thickness and corneal curvature on intraocular pressure measured by tono-pen and rebound tonometer in children.
Sahin A; Basmak H; Yildirim N
J Glaucoma; 2008; 17(1):57-61. PubMed ID: 18303387
[TBL] [Abstract][Full Text] [Related]
2. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.
Bhan A; Browning AC; Shah S; Hamilton R; Dave D; Dua HS
Invest Ophthalmol Vis Sci; 2002 May; 43(5):1389-92. PubMed ID: 11980851
[TBL] [Abstract][Full Text] [Related]
3. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.
Browning AC; Bhan A; Rotchford AP; Shah S; Dua HS
Br J Ophthalmol; 2004 Nov; 88(11):1395-9. PubMed ID: 15489480
[TBL] [Abstract][Full Text] [Related]
4. Positive correlation between Tono-Pen intraocular pressure and central corneal thickness.
Dohadwala AA; Munger R; Damji KF
Ophthalmology; 1998 Oct; 105(10):1849-54. PubMed ID: 9787354
[TBL] [Abstract][Full Text] [Related]
5. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D
Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165
[TBL] [Abstract][Full Text] [Related]
6. Tono-Pen tonometer and corneal thickness.
Mok KH; Wong CS; Lee VW
Eye (Lond); 1999; 13 ( Pt 1)():35-7. PubMed ID: 10396381
[TBL] [Abstract][Full Text] [Related]
7. Intraocular pressure and photorefractive keratectomy: a comparison of three different tonometers.
Garzozi HJ; Chung HS; Lang Y; Kagemann L; Harris A
Cornea; 2001 Jan; 20(1):33-6. PubMed ID: 11189000
[TBL] [Abstract][Full Text] [Related]
8. Correspondence of Tono-Pen intraocular pressure measurements performed at the central cornea and mid-peripheral cornea.
Sullivan-Mee M; Pham F
Optometry; 2004 Jan; 75(1):26-32. PubMed ID: 14717278
[TBL] [Abstract][Full Text] [Related]
9. Tono-Pen versus Goldmann tonometry after excimer laser photorefractive keratectomy.
Levy Y; Zadok D; Glovinsky Y; Krakowski D; Nemet P
J Cataract Refract Surg; 1999 Apr; 25(4):486-91. PubMed ID: 10198852
[TBL] [Abstract][Full Text] [Related]
10. Effect of mild to moderate myopic correction by laser-assisted in situ keratomileusis on intraocular pressure measurements with goldmann applanation tonometer, tono-pen, and pneumatonometer.
Vakili R; Choudhri SA; Tauber S; Shields MB
J Glaucoma; 2002 Dec; 11(6):493-6. PubMed ID: 12483093
[TBL] [Abstract][Full Text] [Related]
11. Intraocular pressure in Lewis rats.
Mermoud A; Baerveldt G; Minckler DS; Lee MB; Rao NA
Invest Ophthalmol Vis Sci; 1994 Apr; 35(5):2455-60. PubMed ID: 8163335
[TBL] [Abstract][Full Text] [Related]
12. Is the tono-pen accurate for measuring intraocular pressure in young children with congenital glaucoma?
Levy J; Lifshitz T; Rosen S; Tessler Z; Biedner BZ
J AAPOS; 2005 Aug; 9(4):321-5. PubMed ID: 16102480
[TBL] [Abstract][Full Text] [Related]
13. Comparison of intraocular pressure measurements with the tono-pen, goldmann applanation tonometer, and noncontact tonometer in nonglaucomatous pseudophakic children.
Oskan Yalcın S; Kaplan AT
Int Ophthalmol; 2024 Jun; 44(1):285. PubMed ID: 38935310
[TBL] [Abstract][Full Text] [Related]
14. Comparison of scleral and corneal Tono-Pen readings.
Kolin T; Wedemeyer LL; Kolin E; Braun Y
J AAPOS; 2003 Aug; 7(4):291-2. PubMed ID: 12917618
[TBL] [Abstract][Full Text] [Related]
15. The influence of central corneal thickness and corneal curvature and axial length on the measurement of intraocular pressure.
Li Q; Li M; Fan Z; Wang N
Yan Ke Xue Bao; 2002 Sep; 18(3):176-80. PubMed ID: 15510750
[TBL] [Abstract][Full Text] [Related]
16. Comparison of the iCare, Tono-Pen, non-contact airpuff, and Goldmann applanation tonometers in eyes with corneal edema after penetrating keratoplasty.
Yeh SJ; Chen KH; Kuang TM; Liu CJ; Chen MJ
J Chin Med Assoc; 2021 Mar; 84(3):320-325. PubMed ID: 33587519
[TBL] [Abstract][Full Text] [Related]
17. Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea.
Azuara-Blanco A; Bhojani TK; Sarhan AR; Pillai CT; Dua HS
Br J Ophthalmol; 1998 Jun; 82(6):634-6. PubMed ID: 9797663
[TBL] [Abstract][Full Text] [Related]
18. Comparison of Oculab Tono-Pen readings obtained from various corneal and scleral locations.
Khan JA; Davis M; Graham CE; Trank J; Whitacre MM
Arch Ophthalmol; 1991 Oct; 109(10):1444-6. PubMed ID: 1929938
[TBL] [Abstract][Full Text] [Related]
19. Central and peripheral pressure measurements with the Goldmann tonometer and Tono-Pen after photorefractive keratectomy for myopia.
Schipper I; Senn P; Oyo-Szerenyi K; Peter R
J Cataract Refract Surg; 2000 Jun; 26(6):929-33. PubMed ID: 10889442
[TBL] [Abstract][Full Text] [Related]
20. Effect of corneal thickness on the accuracy of intraocular pressure measurement in rabbits after excimer laser photoablation.
Stahl J; Vold S
J Cataract Refract Surg; 2000 May; 26(5):736-43. PubMed ID: 10831906
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]