These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 18308228)

  • 1. Let them walk! Current prosthesis options for leg and foot amputees.
    Tang PC; Ravji K; Key JJ; Mahler DB; Blume PA; Sumpio B
    J Am Coll Surg; 2008 Mar; 206(3):548-60. PubMed ID: 18308228
    [No Abstract]   [Full Text] [Related]  

  • 2. Prosthetic options available for the diabetic lower limb amputee.
    Chitragari G; Mahler DB; Sumpio BJ; Blume PA; Sumpio BE
    Clin Podiatr Med Surg; 2014 Jan; 31(1):173-85. PubMed ID: 24296024
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Selection of components for lower limb amputation prostheses.
    Rubin G; Fischer E
    Bull Hosp Jt Dis Orthop Inst; 1982; 42(1):39-67. PubMed ID: 6288154
    [No Abstract]   [Full Text] [Related]  

  • 4. Technical note--tilting stubbies.
    Balakrishnan A
    Prosthet Orthot Int; 1981 Aug; 5(2):85-6. PubMed ID: 7301526
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transfemoral amputee recovery strategies following trips to their sound and prosthesis sides throughout swing phase.
    Shirota C; Simon AM; Kuiken TA
    J Neuroeng Rehabil; 2015 Sep; 12():79. PubMed ID: 26353775
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prosthetic choices for people with leg and arm amputations.
    Kistenberg RS
    Phys Med Rehabil Clin N Am; 2014 Feb; 25(1):93-115. PubMed ID: 24287242
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microprocessor prosthetic knees.
    Berry D
    Phys Med Rehabil Clin N Am; 2006 Feb; 17(1):91-113, vii. PubMed ID: 16517347
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Using a microprocessor knee (C-Leg) with appropriate foot transitioned individuals with dysvascular transfemoral amputations to higher performance levels: a longitudinal randomized clinical trial.
    Jayaraman C; Mummidisetty CK; Albert MV; Lipschutz R; Hoppe-Ludwig S; Mathur G; Jayaraman A
    J Neuroeng Rehabil; 2021 May; 18(1):88. PubMed ID: 34034753
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Below the knee and Syme's amputation prostheses.
    Sinclair WF
    Orthop Clin North Am; 1972 Jul; 3(2):349-57. PubMed ID: 5037521
    [No Abstract]   [Full Text] [Related]  

  • 10. Effects of inertial properties of transfemoral prosthesis on leg swing motion during stair ascent.
    Inoue K; Hobara H; Wada T
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1591-4. PubMed ID: 24110006
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Co-contraction patterns of trans-tibial amputee ankle and knee musculature during gait.
    Seyedali M; Czerniecki JM; Morgenroth DC; Hahn ME
    J Neuroeng Rehabil; 2012 May; 9():29. PubMed ID: 22640660
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Semi-flexible sockets for amputation below the knee.
    Symington DC; Lowe PJ; Mackay S
    Arch Phys Med Rehabil; 1975 Sep; 56(9):399-404. PubMed ID: 1164180
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Construction methods and materials for external prostheses--present and future.
    Foort J; Lawrence RB; Davies RM
    Int Rehabil Med; 1984; 6(2):72-8. PubMed ID: 6746203
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of different microprocessor controlled knee joints on the energy consumption during walking in trans-femoral amputees: intelligent knee prosthesis (IP) versus C-leg.
    Chin T; Machida K; Sawamura S; Shiba R; Oyabu H; Nagakura Y; Takase I; Nakagawa A
    Prosthet Orthot Int; 2006 Apr; 30(1):73-80. PubMed ID: 16739783
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Metabolic effects of using a variable impedance prosthetic knee.
    Williams MR; Herr H; D'Andrea S
    J Rehabil Res Dev; 2016; 53(6):1079-1088. PubMed ID: 28355031
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Early fitting of artificial limbs to amputated lower limbs.
    de Noordhout BM; Pirnay L; de Brogniez A
    Acta Chir Belg; 2004 Aug; 104(4):393-5. PubMed ID: 15469149
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Segment velocities in normal and transtibial amputees: prosthetic design implications.
    Rao SS; Boyd LA; Mulroy SJ; Bontrager EL; Gronley JK; Perry J
    IEEE Trans Rehabil Eng; 1998 Jun; 6(2):219-26. PubMed ID: 9631330
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The efficacy of the Ankle Mimicking Prosthetic Foot prototype 4.0 during walking: Physiological determinants.
    De Pauw K; Cherelle P; Roelands B; Lefeber D; Meeusen R
    Prosthet Orthot Int; 2018 Oct; 42(5):504-510. PubMed ID: 29623812
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Longitudinal gait analysis of a person with a transfemoral amputation using three different prosthetic knee/foot pairs.
    Barr JB; Wutzke CJ; Threlkeld AJ
    Physiother Theory Pract; 2012 Jul; 28(5):407-11. PubMed ID: 22191438
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of the Femurett adjustable prosthesis in the assessment and walking training of new above-knee amputees.
    Parry M; Morrison JD
    Prosthet Orthot Int; 1989 Apr; 13(1):36-8. PubMed ID: 2717383
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.