81 related articles for article (PubMed ID: 18309332)
21. Analysis of GDx-VCC polarimetry data by Wavelet-Fourier analysis across glaucoma stages.
Essock EA; Zheng Y; Gunvant P
Invest Ophthalmol Vis Sci; 2005 Aug; 46(8):2838-47. PubMed ID: 16043858
[TBL] [Abstract][Full Text] [Related]
22. Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma.
Brusini P; Salvetat ML; Zeppieri M; Tosoni C; Parisi L; Felletti M
Acta Ophthalmol Scand; 2006 Oct; 84(5):650-5. PubMed ID: 16965496
[TBL] [Abstract][Full Text] [Related]
23. Comparison of quantitative imaging devices and subjective optic nerve head assessment by general ophthalmologists to differentiate normal from glaucomatous eyes.
Vessani RM; Moritz R; Batis L; Zagui RB; Bernardoni S; Susanna R
J Glaucoma; 2009 Mar; 18(3):253-61. PubMed ID: 19295383
[TBL] [Abstract][Full Text] [Related]
24. Correlation between scanning laser polarimetry with and without enhanced corneal compensation and high-definition optical coherence tomography in normal and glaucomatous eyes.
Benítez-del-Castillo J; Martinez A; Regi T
Int J Clin Pract; 2011 Jul; 65(7):807-16. PubMed ID: 21535460
[TBL] [Abstract][Full Text] [Related]
25. Comparison of retinal nerve fibre layer thickness and visual field loss between different glaucoma groups.
Galvão Filho RP; Vessani RM; Susanna R
Br J Ophthalmol; 2005 Aug; 89(8):1004-7. PubMed ID: 16024854
[TBL] [Abstract][Full Text] [Related]
26. Structure-function relationship is stronger with enhanced corneal compensation than with variable corneal compensation in scanning laser polarimetry.
Mai TA; Reus NJ; Lemij HG
Invest Ophthalmol Vis Sci; 2007 Apr; 48(4):1651-8. PubMed ID: 17389496
[TBL] [Abstract][Full Text] [Related]
27. Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.
Rao HL; Yadav RK; Begum VU; Addepalli UK; Senthil S; Choudhari NS; Garudadri CS
Acta Ophthalmol; 2015 Mar; 93(2):e105-10. PubMed ID: 25270298
[TBL] [Abstract][Full Text] [Related]
28. Detection of structural damage from glaucoma with confocal laser image analysis.
Uchida H; Brigatti L; Caprioli J
Invest Ophthalmol Vis Sci; 1996 Nov; 37(12):2393-401. PubMed ID: 8933756
[TBL] [Abstract][Full Text] [Related]
29. Relationships between standard automated perimetry, HRT confocal scanning laser ophthalmoscopy, and GDx VCC scanning laser polarimetry.
Reus NJ; Lemij HG
Invest Ophthalmol Vis Sci; 2005 Nov; 46(11):4182-8. PubMed ID: 16249497
[TBL] [Abstract][Full Text] [Related]
30. Correlation between optic disc topography and retinal nerve fibre layer measurements in glaucoma.
Magacho L; Marcondes AM; Costa VP
Acta Ophthalmol Scand; 2005 Jun; 83(3):322-7. PubMed ID: 15948785
[TBL] [Abstract][Full Text] [Related]
31. Enhanced imaging algorithm for scanning laser polarimetry with variable corneal compensation.
Reus NJ; Zhou Q; Lemij HG
Invest Ophthalmol Vis Sci; 2006 Sep; 47(9):3870-7. PubMed ID: 16936099
[TBL] [Abstract][Full Text] [Related]
32. Correlation between local glaucomatous visual field defects and loss of nerve fiber layer thickness measured with polarimetry and spectral domain OCT.
Horn FK; Mardin CY; Laemmer R; Baleanu D; Juenemann AM; Kruse FE; Tornow RP
Invest Ophthalmol Vis Sci; 2009 May; 50(5):1971-7. PubMed ID: 19151389
[TBL] [Abstract][Full Text] [Related]
33. Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma.
Medeiros FA; Zangwill LM; Bowd C; Bernd AS; Weinreb RN
Invest Ophthalmol Vis Sci; 2003 Jun; 44(6):2606-12. PubMed ID: 12766063
[TBL] [Abstract][Full Text] [Related]
34. Can frequency-doubling technology and short-wavelength automated perimetries detect visual field defects before standard automated perimetry in patients with preperimetric glaucoma?
Ferreras A; Polo V; Larrosa JM; Pablo LE; Pajarin AB; Pueyo V; Honrubia FM
J Glaucoma; 2007; 16(4):372-83. PubMed ID: 17571000
[TBL] [Abstract][Full Text] [Related]
35. Predicting visual field loss in ocular hypertensive patients using wavelet-fourier analysis of GDx scanning laser polarimetry.
Essock EA; Gunvant P; Zheng Y; Garway-Heath DF; Kotecha A; Spratt A
Optom Vis Sci; 2007 May; 84(5):380-7. PubMed ID: 17502818
[TBL] [Abstract][Full Text] [Related]
36. Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation.
Bagga H; Greenfield DS; Feuer WJ
Am J Ophthalmol; 2005 Mar; 139(3):437-46. PubMed ID: 15767051
[TBL] [Abstract][Full Text] [Related]
37. Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements.
Lauande-Pimentel R; Carvalho RA; Oliveira HC; Gonçalves DC; Silva LM; Costa VP
Br J Ophthalmol; 2001 May; 85(5):586-91. PubMed ID: 11316722
[TBL] [Abstract][Full Text] [Related]
38. Retinal nerve fiber layer measurement repeatability in scanning laser polarimetry with enhanced corneal compensation.
Mai TA; Reus NJ; Lemij HG
J Glaucoma; 2008; 17(4):269-74. PubMed ID: 18552611
[TBL] [Abstract][Full Text] [Related]
39. Comparison of optic nerve imaging methods to distinguish normal eyes from those with glaucoma.
Greaney MJ; Hoffman DC; Garway-Heath DF; Nakla M; Coleman AL; Caprioli J
Invest Ophthalmol Vis Sci; 2002 Jan; 43(1):140-5. PubMed ID: 11773024
[TBL] [Abstract][Full Text] [Related]
40. Logistic regression analysis for early glaucoma diagnosis using optical coherence tomography.
Ferreras A; Pablo LE; Pajarín AB; Larrosa JM; Polo V; Honrubia FM
Arch Ophthalmol; 2008 Apr; 126(4):465-70. PubMed ID: 18413514
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]