BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 18311279)

  • 1. Noncontact temperature measurement by means of CCD cameras in a participating medium.
    Liu D; Wang F; Cen K; Yan J; Huang Q; Chi Y
    Opt Lett; 2008 Mar; 33(5):422-4. PubMed ID: 18311279
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Theoretical and experimental investigation of the thermal resolution and dynamic range of CCD-based thermoreflectance imaging.
    Mayer PM; Lüerssen D; Ram RJ; Hudgings JA
    J Opt Soc Am A Opt Image Sci Vis; 2007 Apr; 24(4):1156-63. PubMed ID: 17361303
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sample-based cameras for feed forward reflection rendering.
    Popescu V; Sacks E; Mei C
    IEEE Trans Vis Comput Graph; 2006; 12(6):1590-600. PubMed ID: 17073380
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Single quantum dots as local temperature markers.
    Li S; Zhang K; Yang JM; Lin L; Yang H
    Nano Lett; 2007 Oct; 7(10):3102-5. PubMed ID: 17727300
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermoacoustic and photoacoustic sensing of temperature.
    Pramanik M; Wang LV
    J Biomed Opt; 2009; 14(5):054024. PubMed ID: 19895126
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An equivalent time temperature mapping system with a 320 x 256 pixels full-frame 100 kHz sampling rate.
    Riccio M; Breglio G; Irace A; Spirito P
    Rev Sci Instrum; 2007 Oct; 78(10):106106. PubMed ID: 17979462
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved MRI thermometry with multiple-echo spirals.
    Marx M; Butts Pauly K
    Magn Reson Med; 2016 Sep; 76(3):747-56. PubMed ID: 26332512
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers.
    Bazán I; Vazquez M; Ramos A; Vera A; Leija L
    Ultrasonics; 2009 Mar; 49(3):358-76. PubMed ID: 19100591
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Method for producing correct fingerprints.
    Rao SM
    Appl Opt; 2008 Jan; 47(1):25-9. PubMed ID: 18157272
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monitoring of tissue thermal modification with a bundle-based full-field speckle analyzer.
    Zimnyakov DA; Sviridov AP; Kuznetsova LV; Baranov SA; Ignatieva NY
    Appl Opt; 2006 Jun; 45(18):4480-90. PubMed ID: 16778958
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computational imaging based on time-correlated single-photon-counting technique at low light level.
    Yang Y; Shi J; Cao F; Peng J; Zeng G
    Appl Opt; 2015 Nov; 54(31):9277-83. PubMed ID: 26560582
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulsed-microwave-induced thermoacoustic tomography: filtered backprojection in a circular measurement configuration.
    Xu M; Wang LV
    Med Phys; 2002 Aug; 29(8):1661-9. PubMed ID: 12201411
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MR thermometry near metallic devices using multispectral imaging.
    Weber H; Taviani V; Yoon D; Ghanouni P; Pauly KB; Hargreaves BA
    Magn Reson Med; 2017 Mar; 77(3):1162-1169. PubMed ID: 26991803
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multiple light source detection.
    Bouganis CS; Brookes M
    IEEE Trans Pattern Anal Mach Intell; 2004 Apr; 26(4):509-14. PubMed ID: 15382654
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Photo-consistent reconstruction of semitransparent scenes by density-sheet decomposition.
    Hasinoff SW; Kutulakos KN
    IEEE Trans Pattern Anal Mach Intell; 2007 May; 29(5):870-85. PubMed ID: 17356205
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analytical light-ray tracing in two-dimensional objects for light-extraction problems in light-emitting diodes.
    Masui H; Nakamura S; DenBaars SP
    Appl Opt; 2008 Jan; 47(1):88-92. PubMed ID: 18157281
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimal-invasive thermal imaging of a malignant tumor: a simple model and algorithm.
    Gescheit IM; Dayan A; Ben-David M; Gannot I
    Med Phys; 2010 Jan; 37(1):211-6. PubMed ID: 20175483
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enhancement of infrared image based on the Retinex theory.
    Li Y; Hou C; Tian F; Yu H; Guo L; Xu G; Shen X; Yan W
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3315-8. PubMed ID: 18002705
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A study of thermographic diagnosis system and imaging algorithm by distributed thermal data using single infrared sensor.
    Yoon SJ; Noh SC; Choi HH
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3319-22. PubMed ID: 18002706
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Acquisition of 3D temperature distributions in fluid flow using proton resonance frequency thermometry.
    Buchenberg WB; Wassermann F; Grundmann S; Jung B; Simpson R
    Magn Reson Med; 2016 Jul; 76(1):145-55. PubMed ID: 26302238
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.