  • 1. In situ 3omega techniques for measuring thermal conductivity of phase-change materials.
    Risk WP; Rettner CT; Raoux S
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):026108. PubMed ID: 18315340
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Temperature-dependent quantitative 3omega scanning thermal microscopy: Local thermal conductivity changes in NiTi microstructures induced by martensite-austenite phase transition.
    Chirtoc M; Gibkes J; Wernhardt R; Pelzl J; Wieck A
    Rev Sci Instrum; 2008 Sep; 79(9):093703. PubMed ID: 19044421
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The freestanding sensor-based 3ω technique for measuring thermal conductivity of solids: principle and examination.
    Qiu L; Tang DW; Zheng XH; Su GP
    Rev Sci Instrum; 2011 Apr; 82(4):045106. PubMed ID: 21529038
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High temperature thermal conductivity of platinum microwire by 3ω method.
    Bhatta RP; Annamalai S; Mohr RK; Brandys M; Pegg IL; Dutta B
    Rev Sci Instrum; 2010 Nov; 81(11):114904. PubMed ID: 21133493
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved 3-omega measurement of thermal conductivity in liquid, gases, and powders using a metal-coated optical fiber.
    Schiffres SN; Malen JA
    Rev Sci Instrum; 2011 Jun; 82(6):064903. PubMed ID: 21721720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermal conductivity measurements using 1ω and 3ω methods revisited for voltage-driven setups.
    Kimling J; Martens S; Nielsch K
    Rev Sci Instrum; 2011 Jul; 82(7):074903. PubMed ID: 21806217
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 3omega method to measure thermal properties of electrically conducting small-volume liquid.
    Choi SR; Kim J; Kim D
    Rev Sci Instrum; 2007 Aug; 78(8):084902. PubMed ID: 17764347
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thermal conductivity measurement of fluids using the 3omega method.
    Lee SM
    Rev Sci Instrum; 2009 Feb; 80(2):024901. PubMed ID: 19256671
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aerosol jet printed 3 omega sensors for thermal conductivity measurement.
    Kempf N; Zhang Y
    Rev Sci Instrum; 2021 Oct; 92(10):105008. PubMed ID: 34717438
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Highly sensitive thermal conductivity measurements of suspended membranes (SiN and diamond) using a 3ω-Völklein method.
    Sikora A; Ftouni H; Richard J; Hébert C; Eon D; Omnès F; Bourgeois O
    Rev Sci Instrum; 2012 May; 83(5):054902. PubMed ID: 22667639
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A "2-omega" technique for measuring anisotropy of thermal conductivity.
    Ramu AT; Bowers JE
    Rev Sci Instrum; 2012 Dec; 83(12):124903. PubMed ID: 23278014
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Solution-phase deposition and nanopatterning of GeSbSe phase-change materials.
    Milliron DJ; Raoux S; Shelby RM; Jordan-Sweet J
    Nat Mater; 2007 May; 6(5):352-6. PubMed ID: 17417642
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Note: Non-destructive measurement of thermal effusivity of a solid and liquid using a freestanding serpentine sensor-based 3ω technique.
    Qiu L; Zheng XH; Zhu J; Tang DW
    Rev Sci Instrum; 2011 Aug; 82(8):086110. PubMed ID: 21895288
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Specific heat measurement of thin suspended SiN membrane from 8 K to 300 K using the 3ω-Völklein method.
    Ftouni H; Tainoff D; Richard J; Lulla K; Guidi J; Collin E; Bourgeois O
    Rev Sci Instrum; 2013 Sep; 84(9):094902. PubMed ID: 24089850
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two omega method for active thermocouple microscopy.
    Thiery L; Gavignet E; Cretin B
    Rev Sci Instrum; 2009 Mar; 80(3):034901. PubMed ID: 19334942
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High throughput, spatially resolved thermal properties measurement using attachable and reusable 3ω sensors.
    Chalise D; Tee R; Zeng Y; Kaur S; Pokharna H; Prasher RS
    Rev Sci Instrum; 2023 Sep; 94(9):. PubMed ID: 37676087