278 related articles for article (PubMed ID: 18316708)
1. Efficacy and safety of biodegradable collagen-glycosaminoglycan polymer as a material for scleral buckling.
Wu WC; Lai CC; Chen HS; Sun MH; Lee LM; Shih CP; Lee HW; Hsu WC
Invest Ophthalmol Vis Sci; 2008 Jun; 49(6):2673-8. PubMed ID: 18316708
[TBL] [Abstract][Full Text] [Related]
2. Efficacy, safety, and biodegradation of a degradable scleral buckle of chitosan-gelatin polymer in rabbits.
Xu T; Yang Y; Yu Y; Zhu R; Chen H
Retina; 2013 May; 33(5):1062-9. PubMed ID: 23296049
[TBL] [Abstract][Full Text] [Related]
3. [Histological changes related to scleral buckling for treatment of retinal detachment].
D'Hermies F; Korobelnik JF; Meyer A; Morel X; Béhar-Cohen F; Bertin S; Chérif N; Chauvaud D; Renard G; Audouin J; Diebold J; Duprez A
Clin Exp Pathol; 1999; 47(5):215-22. PubMed ID: 10598369
[TBL] [Abstract][Full Text] [Related]
4. Histologic analysis of bioabsorbable scleral buckling implants: an experimental study on rabbits.
Länsman S; Pääkkö P; Ryhänen J; Hirvelä H; Kellomäki M; Ellä V; Törmälä P; Waris T; Ashammakhi NA
Retina; 2005 Dec; 25(8):1032-8. PubMed ID: 16340534
[TBL] [Abstract][Full Text] [Related]
5. [Resorbable implant materials in retinal detachment surgery. Initial animal experiment studies].
Guthoff R; Wagner T; Holste J; Winter R
Klin Monbl Augenheilkd; 1993 Jan; 202(1):43-8. PubMed ID: 8464204
[TBL] [Abstract][Full Text] [Related]
6. Encapsulation of scleral buckling materials. A study of sixty specimens.
D'Hermies F; Korobelnik JF; Caputo G; Mashhour B; Chauvaud D; Pouliquen Y; Renard G
Ophthalmology; 1998 Jun; 105(6):1079-86. PubMed ID: 9627660
[TBL] [Abstract][Full Text] [Related]
7. S/e-PTFE episcleral buckling implants: an experimental and histopathologic study.
Mortemousque B; Leger F; Velou S; Graffan R; Colin J; Korobelnik JF
J Biomed Mater Res; 2002; 63(6):686-91. PubMed ID: 12418011
[TBL] [Abstract][Full Text] [Related]
8. [Value of silicone sponge in retinal detachment surgery].
Starzycka M; Kobylarz J; Górniak-Bednarz A; Ortyl E
Klin Oczna; 1993; 95(9-10):346-7. PubMed ID: 8022164
[TBL] [Abstract][Full Text] [Related]
9. Persistence of indentation with bioabsorbable poly-L/D-lactide versus silicone sponge scleral buckling implants.
Länsman SM; Karttunen AI; Hirvelä HK; Palosaari JT; Kellomäki M; Ellä V; Ohtonen PP; Törmälä P; Waris TH; Ashammakhi NA
Retina; 2005; 25(5):581-6. PubMed ID: 16077354
[TBL] [Abstract][Full Text] [Related]
10. [Preliminary results for treatment of rhegmatogenous retinal detachment and new material for episcleral buckle: silicone Korobelnik sponge].
Gribomont AC
Bull Soc Belge Ophtalmol; 2003; (287):73-5. PubMed ID: 12784580
[TBL] [Abstract][Full Text] [Related]
11. The effects of scleral buckling on young rabbit eyes.
Moshfeghi AA; Pendergast SD; Hartzer MK; Ferrone PJ
Arch Ophthalmol; 2004 Apr; 122(4):473-6. PubMed ID: 15078663
[TBL] [Abstract][Full Text] [Related]
12. Expanded polytetrafluoroethylene episcleral implants used as encircling scleral buckling. an experimental and histopathological study.
Korobelnik JF; D'Hermies F; Chauvaud D; Legeais JM; Hoang-Xuan T; Renard G
Ophthalmic Res; 2000; 32(2-3):110-7. PubMed ID: 10754444
[TBL] [Abstract][Full Text] [Related]
13. Changes in higher-order aberrations after scleral buckling surgery for rhegmatogenous retinal detachment.
Okamoto F; Yamane N; Okamoto C; Hiraoka T; Oshika T
Ophthalmology; 2008 Jul; 115(7):1216-21. PubMed ID: 17997487
[TBL] [Abstract][Full Text] [Related]
14. [Retinal detachment surgery: Incidence and causes of silicone sponge implant rejection].
Hanselmayer H; Roll P
Klin Monbl Augenheilkd; 1979 Mar; 174(3):333-41. PubMed ID: 384073
[TBL] [Abstract][Full Text] [Related]
15. [Experimental studies of using polyester-coated materials of Polish production in surgical treatment of retinal detachment].
Kmera-Muszyńska M; Kecik T; Pratnicki A; Zajkowska G; Wael I
Klin Oczna; 1991; 93(4-5):101-4. PubMed ID: 1921212
[TBL] [Abstract][Full Text] [Related]
16. An unusual complication of retinal reattachment surgery.
Ozertürk Y; Bardak Y; Durmus M
Ophthalmic Surg Lasers; 1999 Jun; 30(6):483-4. PubMed ID: 10392738
[TBL] [Abstract][Full Text] [Related]
17. Long-term stability of circumferential silicone sponge scleral buckling exoplants.
Brown DM; Beardsley RM; Fish RH; Wong TP; Kim RY
Retina; 2006; 26(6):645-9. PubMed ID: 16829806
[TBL] [Abstract][Full Text] [Related]
18. Variation of technique of episcleral sponge placement: effect on scleral indentation for retinal detachment repair.
Boldrey EE
Ann Ophthalmol; 1981 Jun; 13(6):743-6. PubMed ID: 7020553
[TBL] [Abstract][Full Text] [Related]
19. Macular microcirculation blood flow changes after conventional surgery for rhegmatogenous retinal detachment.
Kubicka-Trzaska A; Górniak-Bednarz A
Klin Oczna; 2007; 109(4-6):179-82. PubMed ID: 17725281
[TBL] [Abstract][Full Text] [Related]
20. Scleral buckling biomaterials and implants for retinal detachment surgery.
Baino F
Med Eng Phys; 2010 Nov; 32(9):945-56. PubMed ID: 20702127
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]