These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
238 related articles for article (PubMed ID: 18324247)
1. Analysis of a low-finesse Fabry-Perot sensing interferometer illuminated by a multimode optical fiber. Pérennès F; Beard PC; Mills TN Appl Opt; 1999 Dec; 38(34):7026-34. PubMed ID: 18324247 [TBL] [Abstract][Full Text] [Related]
2. Exact analysis of low-finesse multimode fiber extrinsic Fabry-Perot interferometers. Han M; Wang A Appl Opt; 2004 Aug; 43(24):4659-66. PubMed ID: 15352389 [TBL] [Abstract][Full Text] [Related]
3. Crescent shaped Fabry-Perot fiber cavity for ultra-sensitive strain measurement. Liu Y; Wang DN; Chen WP Sci Rep; 2016 Dec; 6():38390. PubMed ID: 27910918 [TBL] [Abstract][Full Text] [Related]
4. Decoding the spectra of low-finesse extrinsic optical fiber Fabry-Perot interferometers. Ma C; Dong B; Gong J; Wang A Opt Express; 2011 Nov; 19(24):23727-42. PubMed ID: 22109399 [TBL] [Abstract][Full Text] [Related]
5. Optical fiber sensing with a low-finesse Fabry-Perot cavity. Santos JL; Leite AP; Jackson DA Appl Opt; 1992 Dec; 31(34):7361-6. PubMed ID: 20802607 [TBL] [Abstract][Full Text] [Related]
6. Low-Finesse Fabry-Pérot Interferometers Applied in the Study of the Relation between the Optical Path Difference and Poles Location. Guillen Bonilla JT; Guillen Bonilla H; Rodríguez Betancourtt VM; Sánchez Morales ME; Gómez JR; Zamora AC; Guillen Bonilla A Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31941162 [TBL] [Abstract][Full Text] [Related]
7. Multimode excitation-induced phase shifts in intrinsic Fabry-Perot interferometric fiber sensor spectra. Ma C; Wang A Appl Opt; 2010 Sep; 49(25):4836-45. PubMed ID: 20820227 [TBL] [Abstract][Full Text] [Related]
8. Optical Fiber Fabry-Pérot Microfluidic Sensor Based on Capillary Fiber and Side Illumination Method. Wu S; Lv N; Geng Y; Chen X; Wang G; He S Sensors (Basel); 2023 Mar; 23(6):. PubMed ID: 36991908 [TBL] [Abstract][Full Text] [Related]
9. Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer. Beard PC; Mills TN Appl Opt; 1996 Feb; 35(4):663-75. PubMed ID: 21069054 [TBL] [Abstract][Full Text] [Related]
10. Analytical model for low finesse, external cavity, fiber Fabry-Perot interferometers including multiple reflections and angular misalignment. Wilkinson PR; Pratt JR Appl Opt; 2011 Aug; 50(23):4671-80. PubMed ID: 21833146 [TBL] [Abstract][Full Text] [Related]
11. Three-dimensional-printed Fabry-Perot interferometer on an optical fiber tip for a gas pressure sensor. Wei H; Chen M; Krishnaswamy S Appl Opt; 2020 Mar; 59(7):2173-2178. PubMed ID: 32225743 [TBL] [Abstract][Full Text] [Related]
12. Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers. Majchrowicz D; Hirsch M; Wierzba P; Bechelany M; Viter R; Jędrzejewska-Szczerska M Sensors (Basel); 2016 Mar; 16(3):. PubMed ID: 27011188 [TBL] [Abstract][Full Text] [Related]
17. Hermetic Welding of an Optical Fiber Fabry-Pérot Cavity for a Diaphragm-Based Pressure Sensor Using CO Zhang H; Li Y; Zhang Z; Yang C; Liang M; Hu Y; Wei H; Pang F Sensors (Basel); 2022 Jun; 22(13):. PubMed ID: 35808196 [TBL] [Abstract][Full Text] [Related]
18. Miniature fiber-optic force sensor for vitreoretinal microsurgery based on low-coherence Fabry-Pérot interferometry. Liu X; Iordachita II; He X; Taylor RH; Kang JU Proc SPIE Int Soc Opt Eng; 2013 Jan; 8218():82180O. PubMed ID: 24027611 [TBL] [Abstract][Full Text] [Related]
19. Passive quadrature demodulation of birefringent low-finesse fiber-optic Fabry-Perot interferometric sensors. Zhu Y; Han M Opt Lett; 2020 Jul; 45(13):3419-3422. PubMed ID: 32630860 [TBL] [Abstract][Full Text] [Related]
20. A Hot-Polymer Fiber Fabry-Perot Interferometer Anemometer for Sensing Airflow. Lee CL; Liu KW; Luo SH; Wu MS; Ma CT Sensors (Basel); 2017 Sep; 17(9):. PubMed ID: 28869510 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]