292 related articles for article (PubMed ID: 18325856)
21. Determination of sodium cromoglycate in human plasma by liquid chromatography with tandem mass.
Liu XY; Qu TT; Wang BJ; Wei CM; Yuan GY; Zhang R; Guo RC
Biomed Chromatogr; 2008 Sep; 22(9):1021-7. PubMed ID: 18506696
[TBL] [Abstract][Full Text] [Related]
22. Simultaneous determination of mifepristone and monodemethyl-mifepristone in human plasma by liquid chromatography-tandem mass spectrometry method using levonorgestrel as an internal standard: application to a pharmacokinetic study.
Tang C; Bi HC; Zhong GP; Chen X; Huang ZY; Huang M
Biomed Chromatogr; 2009 Jan; 23(1):71-80. PubMed ID: 18816505
[TBL] [Abstract][Full Text] [Related]
23. Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of phenylephrine in human plasma and its application to a pharmacokinetic study.
Ptácek P; Klíma J; Macek J
J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Oct; 858(1-2):263-8. PubMed ID: 17900999
[TBL] [Abstract][Full Text] [Related]
24. Liquid chromatography tandem mass spectrometry assay for the simultaneous determination of venlafaxine and O-desmethylvenlafaxine in human plasma and its application to a bioequivalence study.
Patel BN; Sharma N; Sanyal M; Shrivastav PS
J Pharm Biomed Anal; 2008 Jul; 47(3):603-11. PubMed ID: 18387768
[TBL] [Abstract][Full Text] [Related]
25. Profiling of 19-norsteroid sulfoconjugates in human urine by liquid chromatography mass spectrometry.
Strahm E; Rudaz S; Veuthey JL; Saugy M; Saudan C
Anal Chim Acta; 2008 Apr; 613(2):228-37. PubMed ID: 18395062
[TBL] [Abstract][Full Text] [Related]
26. Simultaneous analysis of THC and its metabolites in blood using liquid chromatography-tandem mass spectrometry.
Del Mar Ramirez Fernandez M; De Boeck G; Wood M; Lopez-Rivadulla M; Samyn N
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Nov; 875(2):465-70. PubMed ID: 18922747
[TBL] [Abstract][Full Text] [Related]
27. Rapid and simultaneous determination of tacrolimus (FK506) and diltiazem in human whole blood by liquid chromatography-tandem mass spectrometry: application to a clinical drug-drug interaction study.
Li JL; Wang XD; Wang CX; Fu Q; Liu LS; Huang M; Zhou SF
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 May; 867(1):111-8. PubMed ID: 18417431
[TBL] [Abstract][Full Text] [Related]
28. Simultaneous determination of udenafil and its active metabolite, DA-8164, in human plasma and urine using ultra-performance liquid chromatography-tandem mass spectrometry: application to a pharmacokinetic study.
Bae SK; Kang MJ; Yeo CW; Kim MJ; Shon JH; Liu KH; Shin JG
Biomed Chromatogr; 2008 Sep; 22(9):939-46. PubMed ID: 18651603
[TBL] [Abstract][Full Text] [Related]
29. Determination of a novel paclitaxel derivative (NPD-103) in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.
Zhang SQ; Chen GH
Biomed Chromatogr; 2009 May; 23(5):510-5. PubMed ID: 19016232
[TBL] [Abstract][Full Text] [Related]
30. Rapid and sensitive liquid chromatography tandem mass spectrometry method for the quantification of ambroxol in human plasma.
Hu W; Xu Y; Liu F; Liu A; Guo Q
Biomed Chromatogr; 2008 Oct; 22(10):1108-14. PubMed ID: 18506738
[TBL] [Abstract][Full Text] [Related]
31. Direct detection and quantification of 19-norandrosterone sulfate in human urine by liquid chromatography-linear ion trap mass spectrometry.
Strahm E; Saudan C; Sottas PE; Mangin P; Saugy M
J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):491-6. PubMed ID: 17321808
[TBL] [Abstract][Full Text] [Related]
32. Sensitive and specific LC-ESI-MS/MS method for the determination of a styrylquinoline, BA011FZ041, a potent HIV anti-integrase agent, in rat plasma.
Pruvost A; Levi M; Zouhiri F; Ménier I; Benech H
J Chromatogr B Analyt Technol Biomed Life Sci; 2007 May; 850(1-2):259-66. PubMed ID: 17161029
[TBL] [Abstract][Full Text] [Related]
33. A highly sensitive assay for ritodrine in human serum by hydrophilic interaction chromatography-tandem mass spectrometry.
Ohmori T; Nakamura M; Tada S; Sugiyama T; Itoh Y; Udagawa Y; Hirano K
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jan; 861(1):95-100. PubMed ID: 18054846
[TBL] [Abstract][Full Text] [Related]
34. Quantitative determination of icotinib in human plasma and urine using liquid chromatography coupled to tandem mass spectrometry.
Liu D; Jiang J; Hu P; Tan F; Wang Y
J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Nov; 877(30):3781-6. PubMed ID: 19833564
[TBL] [Abstract][Full Text] [Related]
35. Development and validation of a liquid chromatography-tandem mass spectrometric assay for pitavastatin and its lactone in human plasma and urine.
Tian L; Huang Y; Jia Y; Hua L; Li Y
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Apr; 865(1-2):127-32. PubMed ID: 18342583
[TBL] [Abstract][Full Text] [Related]
36. Sensitive liquid chromatography/tandem mass spectrometry assay for absolute quantification of ITIH4-derived putative biomarker peptides in clinical serum samples.
van den Broek I; Sparidans RW; Schellens JH; Beijnen JH
Rapid Commun Mass Spectrom; 2010 Jul; 24(13):1842-50. PubMed ID: 20533314
[TBL] [Abstract][Full Text] [Related]
37. Development and validation of a sensitive LC-MS/MS method with electrospray ionization for quantitation of pramipexole in human plasma: application to a clinical pharmacokinetic study.
Bharathi DV; Hotha KK; Sagar PV; Kumar SS; Naidu A; Mullangi R
Biomed Chromatogr; 2009 Feb; 23(2):212-8. PubMed ID: 18814193
[TBL] [Abstract][Full Text] [Related]
38. Development and validation of a method for quantitative determination of valsartan in human plasma by liquid chromatography-tandem mass spectrometry.
Koseki N; Kawashita H; Hara H; Niina M; Tanaka M; Kawai R; Nagae Y; Masuda N
J Pharm Biomed Anal; 2007 Apr; 43(5):1769-74. PubMed ID: 17289324
[TBL] [Abstract][Full Text] [Related]
39. Development and validation of a liquid chromatography-tandem mass spectrometry assay for the simultaneous quantitation of prednisolone and dipyridamole in human plasma and its application in a pharmacokinetic study.
Chen M; Granvil C; Ji QC; Zhang ZY; Padval MV; Kansra VV
J Pharm Biomed Anal; 2009 Jul; 49(5):1241-9. PubMed ID: 19304431
[TBL] [Abstract][Full Text] [Related]
40. Quantification of montelukast, a selective cysteinyl leukotriene receptor (CysLT1) antagonist in human plasma by liquid chromatography-mass spectrometry: validation and its application to a human pharmacokinetic study.
Bharathi DV; Hotha KK; Jagadeesh B; Mullangi R; Naidu A
Biomed Chromatogr; 2009 Aug; 23(8):804-10. PubMed ID: 19309765
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]