BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 18328575)

  • 1. Detection of high-risk human papillomavirus by two molecular techniques: hybrid capture and linear array.
    de Antonio JC; Fernández-Olmos A; Mercadillo M; Lindemann ML; Mochales FB
    J Virol Methods; 2008 Apr; 149(1):163-6. PubMed ID: 18328575
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analytical evaluation of the PapilloCheck test, a new commercial DNA chip for detection and genotyping of human papillomavirus.
    Dalstein V; Merlin S; Bali C; Saunier M; Dachez R; Ronsin C
    J Virol Methods; 2009 Mar; 156(1-2):77-83. PubMed ID: 19041893
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of human papillomavirus in cervical cell specimens by hybrid capture and PCR with different primers.
    Szostek S; Klimek M; Zawilinska B; Rys J; Kope J; Daszkiewic E
    Acta Biochim Pol; 2006; 53(3):603-7. PubMed ID: 17019439
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Detection and typing of human papilloma virus by polymerase chain reaction and hybridization assay in cervical samples with cytological abnormalities].
    Ergünay K; Misirlioğlu M; Firat P; Tuncer ZS; Tuncer S; Yildiz I; Ustaçelebi S
    Mikrobiyol Bul; 2008 Apr; 42(2):273-82. PubMed ID: 18697425
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of high-risk HPV types by the hybrid capture 2 test.
    Terry G; Ho L; Londesborough P; Cuzick J; Mielzynska-Lohnas I; Lorincz A
    J Med Virol; 2001 Sep; 65(1):155-62. PubMed ID: 11505458
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An HPV 16, 18, and 45 genotyping test based on Hybrid Capture technology.
    Thai H; Rangwala S; Gay T; Keating K; McLeod S; Nazarenko I; O'Neil D; Pfister D; Loeffert D
    J Clin Virol; 2009 Jul; 45 Suppl 1():S93-7. PubMed ID: 19651375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated extraction and quantitation of oncogenic HPV genotypes from cervical samples by a real-time PCR-based system.
    Broccolo F; Cocuzza CE
    J Virol Methods; 2008 Mar; 148(1-2):48-57. PubMed ID: 18053585
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A novel method of HPV genotyping using Hybrid Capture sample preparation method combined with GP5+/6+ PCR and multiplex detection on Luminex XMAP.
    Nazarenko I; Kobayashi L; Giles J; Fishman C; Chen G; Lorincz A
    J Virol Methods; 2008 Dec; 154(1-2):76-81. PubMed ID: 18835300
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Digene HPV Genotyping RH Test RUO: comparative evaluation with INNO-LiPA HPV Genotyping Extra Test for detection of 18 high-risk and probable high-risk human papillomavirus genotypes.
    Seme K; Lepej SZ; Lunar MM; Iscić-Bes J; Planinić A; Kocjan BJ; Vince A; Poljak M
    J Clin Virol; 2009 Oct; 46(2):176-9. PubMed ID: 19683958
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of human papillomavirus DNA in cervical samples: analysis of the new PGMY-PCR compared to the hybrid capture II and MY-PCR assays and a two-step nested PCR assay.
    Giovannelli L; Lama A; Capra G; Giordano V; Aricò P; Ammatuna P
    J Clin Microbiol; 2004 Aug; 42(8):3861-4. PubMed ID: 15297550
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New approach to human high-risk papillomavirus (HR-HPV) genotyping.
    Weismanová E; Weismann P; Vizváryová M; Lehotská V; Krizanová O; Repiská V; Kausitz J
    Neoplasma; 2002; 49(4):217-24. PubMed ID: 12382018
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The next-generation Hybrid Capture High-Risk HPV DNA assay on a fully automated platform.
    Eder PS; Lou J; Huff J; Macioszek J
    J Clin Virol; 2009 Jul; 45 Suppl 1():S85-92. PubMed ID: 19651374
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and validation of a real-time PCR assay specifically detecting human papillomavirus 52 using the Roche LightCycler 480 system.
    Stevens MP; Garland SM; Tabrizi SN
    J Virol Methods; 2008 Feb; 147(2):290-6. PubMed ID: 17996311
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the PapilloCheck DNA micro-array Human Papillomavirus detection assay with Hybrid Capture II and PCR-enzyme immunoassay using the GP5/6+ primer set.
    Jones J; Powell NG; Tristram A; Fiander AN; Hibbitts S
    J Clin Virol; 2009 Jun; 45(2):100-4. PubMed ID: 19394266
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Human papillomavirus detection and typing in thin prep cervical cytologic specimens comparing the Digene Hybrid Capture II Assay, the Roche Linear Array HPV Genotyping Assay, and the Kurabo GeneSquare Microarray Assay.
    Ermel A; Qadadri B; Morishita A; Miyagawa I; Yamazaki G; Weaver B; Tu W; Tong Y; Randolph M; Cramer H; Brown D
    J Virol Methods; 2010 Oct; 169(1):154-61. PubMed ID: 20670658
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative evaluation of AMPLICOR HPV PCR and Linear Array assays on SurePath liquid-based Pap samples for the detection of high-risk HPV genotypes.
    Chernesky M; Jang D; Portillo E; Smieja M; Chong S; Buracond S; Klingel M; El Sebai R; Kapala J; Patel J; Biers K; Harroun N; Doucette C; Sumner J
    J Clin Virol; 2011 Mar; 50(3):201-4. PubMed ID: 21195020
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Type-specific reproducibility of the Roche linear array HPV genotyping test.
    Steinau M; Swan DC; Unger ER
    J Clin Virol; 2008 Aug; 42(4):412-4. PubMed ID: 18424229
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Human papillomavirus quantification in urine and cervical samples by using the Mx4000 and LightCycler general real-time PCR systems.
    Payan C; Ducancelle A; Aboubaker MH; Caer J; Tapia M; Chauvin A; Peyronnet D; Le Hen E; Arab Z; Legrand MC; Tran A; Postec E; Tourmen F; Avenel M; Malbois C; De Brux MA; Descamps P; Lunel F
    J Clin Microbiol; 2007 Mar; 45(3):897-901. PubMed ID: 17229868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Human papillomavirus typing with a polymerase chain reaction-based genotyping array compared with type-specific PCR.
    Lin CY; Chao A; Yang YC; Chou HH; Ho CM; Lin RW; Chang TC; Chiou JY; Chao FY; Wang KL; Chien TY; Hsueh S; Huang CC; Chen CJ; Lai CH
    J Clin Virol; 2008 Aug; 42(4):361-7. PubMed ID: 18455959
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection of persistent high risk human papillomavirus infections with hybrid capture II and SPF10/LiPA.
    Perrons C; Jelley R; Kleter B; Quint W; Brink N
    J Clin Virol; 2005 Apr; 32(4):278-85. PubMed ID: 15780805
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.