266 related articles for article (PubMed ID: 18331738)
1. Tissue ingrowth in a fully covered self-expandable metallic stent (with videos).
Jaganmohan S; Raju GS
Gastrointest Endosc; 2008 Sep; 68(3):602-4. PubMed ID: 18331738
[No Abstract] [Full Text] [Related]
2. Stent-induced esophageal perforation: treatment by means of placing a second stent after removal of the original stent.
Jung GS; Park SD; Cho YD
Cardiovasc Intervent Radiol; 2008; 31(3):663-8. PubMed ID: 18259810
[TBL] [Abstract][Full Text] [Related]
3. Solving the problem of difficult stent removal due to tissue ingrowth in partially uncovered esophageal self-expanding metal stents.
Langer FB; Schoppmann SF; Prager G; Riegler FM; Zacherl J
Ann Thorac Surg; 2010 May; 89(5):1691-2. PubMed ID: 20417822
[TBL] [Abstract][Full Text] [Related]
4. Endoscopic removal of a fractured partially covered Evolution esophageal stent.
Mou S; Kaltenbach T; Yao M; Corrales CE; McGill S; Soetikno R
Endoscopy; 2012; 44 Suppl 2 UCTN():E378-9. PubMed ID: 23135973
[No Abstract] [Full Text] [Related]
5. Fixation of a covered self-expandable metal stent by means of a polypectomy snare: an easy method to prevent stent migration.
Manes G; Corsi F; Pallotta S; Massari A; Foschi D; Trabucchi E
Dig Liver Dis; 2008 Sep; 40(9):791-3. PubMed ID: 18083080
[TBL] [Abstract][Full Text] [Related]
6. Endoscopic removal of a migrated esophageal self-expandable metal stent after compression with detachable snares through an intact esophageal stent.
An HJ; Lee HY; Kim BW; Park SM; Ji JS; Lee BI; Choi H; Chae HS; Choi KY; Chung IS
Gastrointest Endosc; 2010 Jan; 71(1):205-7. PubMed ID: 19640522
[No Abstract] [Full Text] [Related]
7. Endoscopic retrieval of a migrated esophageal stent using another anchored esophageal stent and an enteroscopy overtube: A novel technique.
Nakahara K; Itoh F
Dig Endosc; 2015 Sep; 27(6):709. PubMed ID: 25963954
[No Abstract] [Full Text] [Related]
8. Novel removable internally fully covered self-expanding metal esophageal stent: feasibility, technique of removal, and tissue response in humans.
Eloubeidi MA; Lopes TL
Am J Gastroenterol; 2009 Jun; 104(6):1374-81. PubMed ID: 19491851
[TBL] [Abstract][Full Text] [Related]
9. Closure of a duodenal stent-induced perforation by endoscopic stent removal and covered self-expandable metal stent placement (with video).
Small AJ; Petersen BT; Baron TH
Gastrointest Endosc; 2007 Nov; 66(5):1063-5. PubMed ID: 17767928
[No Abstract] [Full Text] [Related]
10. Removal of metallic stent by using polyflex stent in esophago-colic anastomotic stricture.
Tunçözgür B; Savaş MC; Işik AF; Sarimehmetoğlu A; Sanli M; Elbeyli L
Ann Thorac Surg; 2006 Nov; 82(5):1913-4. PubMed ID: 17062280
[TBL] [Abstract][Full Text] [Related]
11. Self-expandable metal coil stents in the treatment of benign esophageal strictures refractory to conventional therapy: a case series.
Fiorini A; Fleischer D; Valero J; Israeli E; Wengrower D; Goldin E
Gastrointest Endosc; 2000 Aug; 52(2):259-62. PubMed ID: 10922106
[TBL] [Abstract][Full Text] [Related]
12. Bilateral vocal cord paralysis following stent placement for proximal esophageal stricture.
Gellad ZF; Hampton D; Tebbit CL; Puscas L; Pavey DA
Endoscopy; 2008 Sep; 40 Suppl 2():E150. PubMed ID: 18633878
[No Abstract] [Full Text] [Related]
13. Self-expanding plastic stents in benign esophageal strictures.
Menon S
Gastrointest Endosc; 2008 Aug; 68(2):402; author reply 403. PubMed ID: 18656601
[No Abstract] [Full Text] [Related]
14. An uncommon complication of savary gilliard dilation.
Mohan P; Ramakrishnan R; Venkataraman J
Am J Gastroenterol; 2009 Nov; 104(11):2865. PubMed ID: 19888255
[No Abstract] [Full Text] [Related]
15. Retrieval of a migrated Polyflex stent--a novel technique.
Dinani AM; Cortes RA; Sridhara S; Reichert S; Somnay K
Endoscopy; 2009; 41 Suppl 2():E304-5. PubMed ID: 19921602
[No Abstract] [Full Text] [Related]
16. Removal of long-term tracheal stents with excellent tracheal healing.
Ranu H; Evans J; Sheth A; Madden BP
Ann Thorac Surg; 2010 Feb; 89(2):598-9. PubMed ID: 20103350
[TBL] [Abstract][Full Text] [Related]
17. Self-expandable covered metal tracheal type stent for sealing cervical anastomotic leak after esophagectomy and gastric pull-up: pitfalls and possibilities.
Lindenmann J; Matzi V; Porubsky C; Anegg U; Sankin O; Gabor S; Neuboeck N; Maier A; Smolle-Juettner FM
Ann Thorac Surg; 2008 Jan; 85(1):354-6. PubMed ID: 18154853
[TBL] [Abstract][Full Text] [Related]
18. Expandable stents for benign esophageal disease.
Dua KS
Gastrointest Endosc Clin N Am; 2011 Jul; 21(3):359-76, vii. PubMed ID: 21684459
[TBL] [Abstract][Full Text] [Related]
19. Airway obstruction complicating esophageal stent placement in two post-pneumonectomy patients.
Farivar AS; Vallières E; Kowdley KV; Wood DE; Mulligan MS
Ann Thorac Surg; 2004 Aug; 78(2):e22-3. PubMed ID: 15276582
[TBL] [Abstract][Full Text] [Related]
20. Multimodal endoscopic treatment for delayed severe esophageal stricture caused by incomplete stent removal.
Setoyma T; Miyamoto S; Horimatsu T; Morita S; Ezoe Y; Muto M; Watanabe G; Tanaka E; Chiba T
Dis Esophagus; 2014; 27(2):112-5. PubMed ID: 23441591
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]