These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 1833179)

  • 41. An evaluation of knot integrity when tied robotically and conventionally.
    Muffly T; McCormick TC; Dean J; Bonham A; Hill RF
    Am J Obstet Gynecol; 2009 May; 200(5):e18-20. PubMed ID: 19111718
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.
    Landman J; Kerbl K; Rehman J; Andreoni C; Humphrey PA; Collyer W; Olweny E; Sundaram C; Clayman RV
    J Urol; 2003 Feb; 169(2):697-700. PubMed ID: 12544345
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A biomechanical study of the aponeurotic inguinal hernia repair.
    Lipton S; Estrin J; Nathan I
    J Am Coll Surg; 1994 Jun; 178(6):595-9. PubMed ID: 8193752
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparison of Maxon suture with Vicryl, chromic catgut, and PDS sutures in fascial closure in rats.
    Sanz LE; Patterson JA; Kamath R; Willett G; Ahmed SW; Butterfield AB
    Obstet Gynecol; 1988 Mar; 71(3 Pt 1):418-22. PubMed ID: 3126470
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Newly designed laparoscopic retractable dissector and suture passer.
    Chung SY; Chon CH; Ng CS; Fuchs GJ
    Urology; 2005 Feb; 65(2):374-7. PubMed ID: 15708056
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Biomechanical characteristics of 10 arthroscopic knots.
    Hassinger SM; Wongworawat MD; Hechanova JW
    Arthroscopy; 2006 Aug; 22(8):827-32. PubMed ID: 16904578
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Comparison and performance characteristics of 3 different knots when tied with 2 suture materials used for shoulder arthroscopy.
    Mahar AT; Moezzi DM; Serra-Hsu F; Pedowitz RA
    Arthroscopy; 2006 Jun; 22(6):614.e1-2. PubMed ID: 16762698
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Safety of a thermal vessel sealer on main pulmonary vessels.
    Lacin T; Batirel HF; Ozer K; Demirutku A; Ahiskali R; Yuksel M
    Eur J Cardiothorac Surg; 2007 Mar; 31(3):482-5; discussion 485. PubMed ID: 17239609
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Strength of knots in surgery in relation to type of knot, type of suture material and dimension of suture thread.
    Tera H; Aberg C
    Acta Chir Scand; 1977; 143(2):75-83. PubMed ID: 899593
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A new and effective tension-band braided polyester suture technique for transverse patellar fracture fixation.
    Hughes SC; Stott PM; Hearnden AJ; Ripley LG
    Injury; 2007 Feb; 38(2):212-22. PubMed ID: 17098238
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Square not a running knot.
    Aanning HL; Haas T; Jorgensen DR; Wulf CA
    J Am Coll Surg; 2007 Mar; 204(3):422-5. PubMed ID: 17324776
    [TBL] [Abstract][Full Text] [Related]  

  • 52. An efficient hand-tying technique for vessel ligation.
    Sandwell S; Hazani R; Kasdan M
    Am Surg; 2009 Nov; 75(11):1098-9. PubMed ID: 19927513
    [TBL] [Abstract][Full Text] [Related]  

  • 53. The effect of number of throws on knot security with nonidentical sliding knots.
    Ivy JJ; Unger JB; Hurt J; Mukherjee D
    Am J Obstet Gynecol; 2004 Nov; 191(5):1618-20. PubMed ID: 15547532
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Tensile strength of surgical knots in abdominal wound closure.
    Fong ED; Bartlett AS; Malak S; Anderson IA
    ANZ J Surg; 2008 Mar; 78(3):164-6. PubMed ID: 18269480
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Sealing of pulmonary arteries with LigaSure: in vivo and ex vivo examinations.
    Lesser TG; Wolfram F; Boltze C
    J Thorac Cardiovasc Surg; 2013 Jun; 145(6):1525-8. PubMed ID: 23228409
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Dynamic loading of surgical knots.
    Brouwers JE; Oosting H; de Haas D; Klopper PJ
    Surg Gynecol Obstet; 1991 Dec; 173(6):443-8. PubMed ID: 1948600
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Use of Roeder knot with vicryl-reel ligature for laparoscopic appendicectomy: have we forgotten how to tie knots?
    Stevens P
    Ann R Coll Surg Engl; 2012 Jan; 94(1):63. PubMed ID: 22524936
    [No Abstract]   [Full Text] [Related]  

  • 58. A simple technique of securing inferior epigastric vessels and repairing the rectus sheath at laparoscopic surgery.
    Chatzipapas IK; Magos AL
    Obstet Gynecol; 1997 Aug; 90(2):304-6. PubMed ID: 9241313
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Use of titanium knot placement device (TK-5) to secure dorsal vein complex during laparoscopic radical prostatectomy and cystoprostatectomy.
    Abreu SC; Rubinstein M; Messias FI; Argollo RS; Guedes GA; Araújo MB; Rubinstein I; Cerqueira JB; Fonseca GN
    Urology; 2006 Jan; 67(1):190-4. PubMed ID: 16413363
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Selective versus standard ligature of the deep venous complex during laparoscopic radical prostatectomy: effects on continence, blood loss, and margin status.
    Porpiglia F; Fiori C; Grande S; Morra I; Scarpa RM
    Eur Urol; 2009 Jun; 55(6):1377-83. PubMed ID: 19243886
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.