BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

309 related articles for article (PubMed ID: 18334442)

  • 1. Perturbative refinement of the geometric calibration in pinhole SPECT.
    Defrise M; Vanhove C; Nuyts J
    IEEE Trans Med Imaging; 2008 Feb; 27(2):204-14. PubMed ID: 18334442
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of pinhole SPECT acquisition geometry.
    Bequé D; Nuyts J; Bormans G; Suetens P; Dupont P
    IEEE Trans Med Imaging; 2003 May; 22(5):599-612. PubMed ID: 12846429
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pinhole SPECT with different data acquisition geometries: usefulness of unified projection operators in homogeneous coordinates.
    Wang Y; Tsui BM
    IEEE Trans Med Imaging; 2007 Mar; 26(3):298-308. PubMed ID: 17354636
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Single and multipinhole collimator design evaluation method for small animal SPECT.
    Vunckx K; Beque D; Defrise M; Nuyts J
    IEEE Trans Med Imaging; 2008 Jan; 27(1):36-46. PubMed ID: 18270060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intrinsic uniformity requirements for pinhole SPECT.
    Seret A; Bleeser F
    J Nucl Med Technol; 2006 Mar; 34(1):43-7. PubMed ID: 16517968
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.
    Holen RV; Vandenberghe S; Staelens S; De Beenhouwer J; Lemahieu I
    Phys Med Biol; 2009 Feb; 54(3):715-29. PubMed ID: 19131666
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multi-pinhole SPECT calibration: influence of data noise and systematic orbit deviations.
    Zhou L; Vunckx K; Nuyts J
    IEEE Trans Med Imaging; 2011 Oct; 30(10):1795-807. PubMed ID: 21536518
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Small animal imaging with multi-pinhole SPECT.
    Nuyts J; Vunckx K; Defrise M; Vanhove C
    Methods; 2009 Jun; 48(2):83-91. PubMed ID: 19328232
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera.
    Gambhir SS; Berman DS; Ziffer J; Nagler M; Sandler M; Patton J; Hutton B; Sharir T; Haim SB; Haim SB
    J Nucl Med; 2009 Apr; 50(4):635-43. PubMed ID: 19339672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative rotating multisegment slant-hole SPECT mammography with attenuation and collimator-detector response compensation.
    Xu J; Liu C; Wang Y; Frey EC; Tsui BM
    IEEE Trans Med Imaging; 2007 Jul; 26(7):906-16. PubMed ID: 17649904
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization of geometrical calibration in pinhole SPECT.
    Bequé D; Nuyts J; Suetens P; Bormans G
    IEEE Trans Med Imaging; 2005 Feb; 24(2):180-90. PubMed ID: 15707244
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A SVD-based method to assess the uniqueness and accuracy of SPECT geometrical calibration.
    Ma T; Yao R; Shao Y; Zhou R
    IEEE Trans Med Imaging; 2009 Dec; 28(12):1929-39. PubMed ID: 19556192
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simple camera calibration from a single image using five points on two orthogonal 1-D objects.
    Miyagawa I; Arai H; Koike H
    IEEE Trans Image Process; 2010 Jun; 19(6):1528-38. PubMed ID: 20129859
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An efficient analytical calculation of probability matrix in 2D SPECT.
    Loudos GK
    Comput Med Imaging Graph; 2008 Mar; 32(2):83-94. PubMed ID: 17981436
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of novel whole-body high-resolution rodent SPECT (Linoview) based on direct acquisition of linogram projections.
    Walrand S; Jamar F; de Jong M; Pauwels S
    J Nucl Med; 2005 Nov; 46(11):1872-80. PubMed ID: 16269602
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A pinhole gamma camera with optical depth-of-interaction elimination.
    Korevaar MA; Heemskerk JW; Beekman FJ
    Phys Med Biol; 2009 Jul; 54(13):N267-72. PubMed ID: 19521006
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computer-aided evaluation of anatomical accuracy of image fusion between X-ray CT and SPECT.
    Han J; Köstler H; Bennewitz C; Kuwert T; Hornegger J
    Comput Med Imaging Graph; 2008 Jul; 32(5):388-95. PubMed ID: 18468862
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 1D camera geometry and its application to the self-calibration of circular motion sequences.
    Wong KY; Zhang G; Liang C; Zhang H
    IEEE Trans Pattern Anal Mach Intell; 2008 Dec; 30(12):2243-8. PubMed ID: 18988956
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences.
    Jaszczak RJ
    Phys Med Biol; 2006 Jul; 51(13):R99-115. PubMed ID: 16790923
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Camera calibration from video of a walking human.
    Lv F; Zhao T; Nevatia R
    IEEE Trans Pattern Anal Mach Intell; 2006 Sep; 28(9):1513-8. PubMed ID: 16929736
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.