These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 18345160)

  • 1. Remote-sensing infrared thermometer with radiation balancing.
    Harigovindan S; Sobha KS
    Appl Opt; 2000 May; 39(15):2461-6. PubMed ID: 18345160
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-Precision Measurement of Sea Surface Temperature with Integrated Infrared Thermometer.
    Zhang K; Wang X
    Sensors (Basel); 2022 Feb; 22(5):. PubMed ID: 35271019
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An Oil-Bath-Based 293 K to 473 K Blackbody Source.
    Fowler JB
    J Res Natl Inst Stand Technol; 1996; 101(5):629-637. PubMed ID: 27805082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis and improvements of effective emissivities of nonisothermal blackbody cavities.
    He S; Dai C; Wang Y; Liu J; Feng G; Wang J
    Appl Opt; 2020 Aug; 59(23):6977-6983. PubMed ID: 32788789
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Third Generation Water Bath Based Blackbody Source.
    Fowler JB
    J Res Natl Inst Stand Technol; 1995; 100(5):591-599. PubMed ID: 29151763
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A method for optimizing the reference temperature in the effective emissivity calculation of nonisothermal blackbody cavities.
    He S; Dai C; Wang Y; Liu J; Xie Y; Feng G; Wang J
    Opt Express; 2020 Sep; 28(20):29829-29842. PubMed ID: 33114873
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A millikelvin precision temperature control system designed for a low cost, portable and variable temperature blackbody from 298.15 to 693.15 K.
    Liang P; Hu T; Xu J; Xu Q; Ding J
    Rev Sci Instrum; 2023 May; 94(5):. PubMed ID: 37125858
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Infrared cameras are potential traceable "fixed points" for future thermometry studies.
    Yap Kannan R; Keresztes K; Hussain S; Coats TJ; Bown MJ
    J Med Eng Technol; 2015; 39(8):485-9. PubMed ID: 26468981
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigation of High-Temperature Normal Infrared Spectral Emissivity of ZrO
    Zhang T; Song X; Qi G; An B; Dong W; Zhao Y; Wang Z; Yi X; Yuan Z; Zhao Y; Sun L; Mao H
    Materials (Basel); 2021 Dec; 15(1):. PubMed ID: 35009381
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of surface temperature and emissivity by a multitemperature method for Fourier-transform infrared spectrometers.
    Clausen S; Morgenstjerne A; Rathmann O
    Appl Opt; 1996 Oct; 35(28):5683-91. PubMed ID: 21127576
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design, Fabrication, and Performance Evaluation of Portable and Large-Area Blackbody System.
    Bae JY; Choi W; Hong SJ; Kim S; Kim E; Lee CH; Han YH; Hur H; Lee KS; Chang KS; Kim GH; Kim G
    Sensors (Basel); 2020 Oct; 20(20):. PubMed ID: 33076430
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Highly emissive spaceborne blackbody radiation source based on light capture.
    Zhou J; Hao X; Wang X; Song J; Xing Z; Li X; Wang B; Han C; Sima RH
    Opt Express; 2022 Jun; 30(12):20859-20870. PubMed ID: 36224821
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of thermal radiation using regular glass optics and short-wave infrared detectors.
    Yoon HW; Eppeldauer GP
    Opt Express; 2008 Jan; 16(2):937-49. PubMed ID: 18542168
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Thermal infrared emissivity spectrum and its characteristics of crude oil slick covered seawater.
    Xiong P; Gu XF; Yu T; Meng QY; Li JG; Shi JX; Cheng Y; Wang L; Liu WS; Liu QY; Zhao LM
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Nov; 34(11):2953-60. PubMed ID: 25752038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A method for improving temperature measurement accuracy on an infrared thermometer for the ambient temperature field.
    Cui S; Sun B; Sun X
    Rev Sci Instrum; 2020 May; 91(5):054903. PubMed ID: 32486718
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thermodynamic-temperature determinations of the Ag and Au freezing temperatures using a detector-based radiation thermometer.
    Yoon HW; Allen DW; Gibson CE; Litorja M; Saunders RD; Brown SW; Eppeldauer GP; Lykke KR
    Appl Opt; 2007 May; 46(15):2870-80. PubMed ID: 17514232
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Systematic errors in the measurement of emissivity caused by directional effects.
    Kribus A; Vishnevetsky I; Rotenberg E; Yakir D
    Appl Opt; 2003 Apr; 42(10):1839-46. PubMed ID: 12683764
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Temperature-Automated Calibration Methods for a Large-Area Blackbody Radiation Source.
    Yang W; Cao C; Huang P; Bai J; Zhao B; Zhu S; Jin H; Jin K; He X; Li C; Wang J; Liu S; Qi H
    Sensors (Basel); 2024 Mar; 24(5):. PubMed ID: 38475243
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Temperature and emissivity measurement algorithm using a moving emissivity retardation spectral window method based on Lagrange mean value theorem.
    Luan Y; Wang X; He Z; Mao Z; Yang Q
    Appl Opt; 2023 Jul; 62(21):5727-5734. PubMed ID: 37707190
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Study on Method for Measuring Coating Emissivity by Applying Active Irradiation Based on Infrared Thermal Imager.
    Li Y; Zhang P; Chen G; Li Y; Hua W; Li Y; Jiao Z
    Sensors (Basel); 2022 Mar; 22(6):. PubMed ID: 35336563
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.