These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 18345291)

  • 1. Comparison between staple and vessel sealing device for parynchemal transection in laparoscopic liver surgery in a swine model.
    Saidi RF; Ahad A; Escobar R; Nalbantoglu I; Adsay V; Jacobs MJ
    HPB (Oxford); 2007; 9(6):440-3. PubMed ID: 18345291
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Laparoscopic nonanatomic hepatic resection employing the LigaSure device.
    Constant DL; Slakey DP; Campeau RJ; Dunne JB
    JSLS; 2005; 9(1):35-8. PubMed ID: 15791967
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Perioperative outcome of laparoscopic left lateral liver resection is improved by using a bioabsorbable staple line reinforcement material in a porcine model.
    Consten EC; Dakin GF; Robertus JL; Bardaro S; Milone L; Gagner M
    Surg Endosc; 2008 May; 22(5):1188-93. PubMed ID: 18246395
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The vessel sealing system (LigaSure) in hepatic resection: a randomized controlled trial.
    Ikeda M; Hasegawa K; Sano K; Imamura H; Beck Y; Sugawara Y; Kokudo N; Makuuchi M
    Ann Surg; 2009 Aug; 250(2):199-203. PubMed ID: 19638927
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study.
    Nanashima A; Abo T; Arai J; Takagi K; Matsumoto H; Takeshita H; Tsuchiya T; Nagayasu T
    Int J Surg; 2013; 11(9):891-7. PubMed ID: 23954369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Optimum hepatic parenchymal dissection to prevent bile leak: a comparative study using electrosurgical and stapling devices in swine].
    Ikeda T; Akahoshi T; Kawanaka H; Uchiyama H; Yamashita Y; Morita M; Oki E; Saeki H; Sugimachi K; Ikegami T; Yoshizumi T; Soejima Y; Shirabe K; Mimori K; Watanabe M; Hashizume M; Maehara Y
    Fukuoka Igaku Zasshi; 2013 Dec; 104(12):507-14. PubMed ID: 24693678
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Perioperative outcome of laparoscopic left lateral liver resection is improved by using staple line reinforcement technique: a case report.
    Consten EC; Gagner M
    J Gastrointest Surg; 2005 Mar; 9(3):360-4. PubMed ID: 15749597
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Randomized clinical trial of stapler hepatectomy versus LigaSure™ transection in elective hepatic resection.
    Fritzmann J; Kirchberg J; Sturm D; Ulrich AB; Knebel P; Mehrabi A; Büchler MW; Weitz J; Reissfelder C; Rahbari NN
    Br J Surg; 2018 Aug; 105(9):1119-1127. PubMed ID: 30069876
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of stapling devices in liver surgery: Current status and future prospects.
    Yao DB; Wu SD
    World J Gastroenterol; 2016 Aug; 22(31):7091-8. PubMed ID: 27610019
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety and Efficacy of a New Bipolar Energy Device for Parenchymal Dissection in Laparoscopic Liver Resection.
    Dural C; Akyuz M; Yazici P; Aksoy E; Aucejo F; Quintini C; Miller C; Fung J; Berber E
    Surg Laparosc Endosc Percutan Tech; 2016 Feb; 26(1):21-4. PubMed ID: 26836626
    [TBL] [Abstract][Full Text] [Related]  

  • 11. LigaSure versus CUSA for parenchymal transection during laparoscopic hepatectomy in hepatocellular carcinoma patients with cirrhosis: a propensity score-matched analysis.
    Liu F; Wei Y; Li H; Wang W; Wen T; Wu H; Yang J; Xu M; Li B
    Surg Endosc; 2018 May; 32(5):2454-2465. PubMed ID: 29124405
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy and quality of vessel sealing: comparison of a reusable with a disposable device and effects of clamp surface geometry and structure.
    Richter S; Kollmar O; Schilling MK; Pistorius GA; Menger MD
    Surg Endosc; 2006 Jun; 20(6):890-4. PubMed ID: 16738977
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laparoscopic blood-saving liver resection using a new radiofrequency-assisted device: preliminary report of an in vivo study with pig liver.
    Navarro A; Burdio F; Berjano EJ; Güemes A; Sousa R; Rufas M; Subirá J; Gonzalez A; Burdío JM; Castiella T; Tejero E; De Gregorio MA; Grande L; Lozano R
    Surg Endosc; 2008 May; 22(5):1384-91. PubMed ID: 18322742
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clip on Staple Method to Prevent Bile Leakage in Anatomical Liver Resection Using Stapling Devices.
    Ninomiya M; Tomino T; Matono R; Nishizaki T
    Anticancer Res; 2020 Jan; 40(1):401-404. PubMed ID: 31892593
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Usefulness of LigaSure for liver resection: analysis by randomized clinical trial.
    Saiura A; Yamamoto J; Koga R; Sakamoto Y; Kokudo N; Seki M; Yamaguchi T; Yamaguchi T; Muto T; Makuuchi M
    Am J Surg; 2006 Jul; 192(1):41-5. PubMed ID: 16769273
    [TBL] [Abstract][Full Text] [Related]  

  • 16. InLine radiofrequency ablation-assisted laparoscopic liver resection: first experiment with stapling device.
    Yao P; Gunasegaram A; Ladd LA; Chu F; Morris DL
    ANZ J Surg; 2007 Jun; 77(6):480-4. PubMed ID: 17501891
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Laparoscopic liver resection using a bipolar vessel-sealing device: LigaSure.
    Slakey DP
    HPB (Oxford); 2008; 10(4):253-5. PubMed ID: 18773105
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laparoscopic right hepatectomy with intrahepatic transection of the right bile duct.
    Tsai TJ; Chouillard EK; Gumbs AA
    Ann Surg Oncol; 2012 Feb; 19(2):467-8. PubMed ID: 21822559
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Left-sided hepatectomy with a linear stapling device: an experimental study on pigs.
    Zilling T; Walther BS; Holmin T
    HPB Surg; 1992; 6(1):51-5. PubMed ID: 1467316
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Feasibility Study of a Newly Developed Hybrid Energy Device Used During Laparoscopic Liver Resection in a Porcine Model.
    Wakabayashi T; Abe Y; Kanazawa A; Oshima G; Kodai S; Ehara K; Kinugasa Y; Kinoshita T; Nomura A; Kawakubo H; Kitagawa Y
    Surg Innov; 2019 Jun; 26(3):350-358. PubMed ID: 30419791
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.