BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 1834838)

  • 1. Laparoscopic clips. Evaluation of absorbable and titanium with regard to hemostasis and tissue reactivity.
    Grainger DA; Meyer WR; DeCherney AH; Diamond MP
    J Reprod Med; 1991 Jul; 36(7):493-5. PubMed ID: 1834838
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of titanium and absorbable polymeric surgical clips for use in laparoscopic cholecystectomy.
    Klein RD; Jessup G; Ahari F; Connolly RJ; Schwaitzberg SD
    Surg Endosc; 1994 Jul; 8(7):753-8. PubMed ID: 7974100
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanisms of hemostatic failure during laparoscopic nephrectomy: review of Food and Drug Administration database.
    Hsi RS; Saint-Elie DT; Zimmerman GJ; Baldwin DD
    Urology; 2007 Nov; 70(5):888-92. PubMed ID: 17919695
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adhesion formation to the uterine horn of the rat in response to nylon and a new absorbable clip.
    Lavy G; Graebe RA; Oelsner G; Boyers SP; DeCherney AH
    Surg Gynecol Obstet; 1987 Mar; 164(3):204-6. PubMed ID: 3824109
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Value of absorbable clips in laparoscopic cholecystectomy. A randomized prospective study].
    Rohr S; De Manzini N; Vix J; Tiberio G; Wantz C; Meyer C
    J Chir (Paris); 1997 Sep; 134(4):180-4. PubMed ID: 9499947
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A clinical evaluation of absorbable polydioxanone ligating clips in abdominal and pelvic operations.
    Clarke-Pearson DL; Creasman WT
    Surg Gynecol Obstet; 1985 Sep; 161(3):250-2. PubMed ID: 3929412
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid neurorrhaphy with titanium clips.
    Park JW; Lee KS; Kim SK; Park JH; Hong JS; Oh KJ
    Microsurgery; 2002; 22(8):386-90. PubMed ID: 12497577
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of absorbable clips compared with metal clips for cystic duct ligation in laparoscopic cholecystectomy.
    Yano H; Okada K; Kinuta M; Nakano Y; Tono T; Matsui S; Iwazawa T; Kanoh T; Monden T
    Surg Today; 2003; 33(1):18-23. PubMed ID: 12560902
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Experimental study of an absorbable hemostatic clip].
    Ponsot Y; Michel F; Roland J; Pays D; Gattegno B; Rouquette AM; Thibault P
    J Chir (Paris); 1984 Jan; 121(1):33-7. PubMed ID: 6425307
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of copolymer staple versus chromic suture during hysterectomy: gross, histologic, and microbiologic findings.
    Weinstein SA
    Obstet Gynecol; 1989 May; 73(5 Pt 1):829-30. PubMed ID: 2704513
    [No Abstract]   [Full Text] [Related]  

  • 11. The use of absorbable clips in laparoscopic cholecystectomy.
    Hawasli A
    J Laparoendosc Surg; 1994 Oct; 4(5):333-8. PubMed ID: 7833518
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-clip laparoscopic colectomy using electrothermal bipolar vessel sealer clinical experiences.
    Takada M; Ichihara T; Kuroda Y
    Hepatogastroenterology; 2006; 53(72):840-2. PubMed ID: 17153436
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laparoscopic knot substitutes. An assessment of techniques of securing sutures through the laparoscope.
    Andrews SM; Lewis JL
    Endosc Surg Allied Technol; 1994 Feb; 2(1):62-5. PubMed ID: 8081918
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tissue reactivity and degradation patterns of absorbable vascular ligating clips implanted in peritoneum and rectus fascia.
    Chegini N; Metz SA; Masterson BJ
    J Biomed Mater Res; 1990 Jul; 24(7):929-37. PubMed ID: 2118910
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel technique and instrumentation for laparoscopic application of hemostatic clips.
    Chin AK; Moll FH; McColl MB
    J Am Assoc Gynecol Laparosc; 1994 Feb; 1(2):150-3. PubMed ID: 9050479
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Hem-o-lok clip is safe for laparoscopic nephrectomy: a multi-institutional review.
    Ponsky L; Cherullo E; Moinzadeh A; Desai M; Kaouk J; Haber GP; Chen D; Ng C; Fuchs G; Singh D; Finelli A; Frank I; Matin S
    Urology; 2008 Apr; 71(4):593-6. PubMed ID: 18295866
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of peritoneal closure and suture material on adhesion formation in a rabbit model.
    Whitfield RR; Stills HF; Huls HR; Crouch JM; Hurd WW
    Am J Obstet Gynecol; 2007 Dec; 197(6):644.e1-5. PubMed ID: 18060964
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Our experience with the use of Absolok polydioxanone resorbable clips in laparoscopic surgery].
    Veronese E; Elio A; Residori C; Frigo F; Salvato S; Orcalli F
    Minerva Chir; 1999 Mar; 54(3):195-7. PubMed ID: 10352533
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adhesion induction by suture of varying tissue reactivity and caliber.
    Holtz G
    Int J Fertil; 1982; 27(3):134-5. PubMed ID: 6128317
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Absorbable versus non-absorbable sutures in ovarian microsurgery: experimental results in the rabbit model.
    Marana R; Muzii L; Catalano GF; Muscatello P; Mancuso S
    Acta Eur Fertil; 1990; 21(6):309-11. PubMed ID: 2132484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.