1. Validation of a self-applied unattended monitor for sleep disordered breathing. Ayappa I; Norman RG; Seelall V; Rapoport DM J Clin Sleep Med; 2008 Feb; 4(1):26-37. PubMed ID: 18350959 [TBL] [Abstract][Full Text] [Related]
2. Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation. Pittman SD; Ayas NT; MacDonald MM; Malhotra A; Fogel RB; White DP Sleep; 2004 Aug; 27(5):923-33. PubMed ID: 15453551 [TBL] [Abstract][Full Text] [Related]
3. Comparison of limited monitoring using a nasal-cannula flow signal to full polysomnography in sleep-disordered breathing. Ayappa I; Norman RG; Suryadevara M; Rapoport DM Sleep; 2004 Sep; 27(6):1171-9. PubMed ID: 15532212 [TBL] [Abstract][Full Text] [Related]
4. Follow-up assessment of CPAP efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry. Pittman SD; Pillar G; Berry RB; Malhotra A; MacDonald MM; White DP Sleep Breath; 2006 Sep; 10(3):123-31. PubMed ID: 16586136 [TBL] [Abstract][Full Text] [Related]
5. Automated detection of sleep disordered breathing using a nasal pressure monitoring device. Grover SS; Pittman SD Sleep Breath; 2008 Nov; 12(4):339-45. PubMed ID: 18368430 [TBL] [Abstract][Full Text] [Related]
6. Description and validation of the apnea risk evaluation system: a novel method to diagnose sleep apnea-hypopnea in the home. Westbrook PR; Levendowski DJ; Cvetinovic M; Zavora T; Velimirovic V; Henninger D; Nicholson D Chest; 2005 Oct; 128(4):2166-75. PubMed ID: 16236870 [TBL] [Abstract][Full Text] [Related]
7. Diagnostic performance of single airflow channel recording (ApneaLink) in home diagnosis of sleep apnea. Ragette R; Wang Y; Weinreich G; Teschler H Sleep Breath; 2010 Jun; 14(2):109-14. PubMed ID: 19714380 [TBL] [Abstract][Full Text] [Related]
8. Validation of the Apnea Risk Evaluation System (ARES) device against laboratory polysomnography in pregnant women at risk for obstructive sleep apnea syndrome. Sharkey KM; Waters K; Millman RP; Moore R; Martin SM; Bourjeily G J Clin Sleep Med; 2014 May; 10(5):497-502. PubMed ID: 24910550 [TBL] [Abstract][Full Text] [Related]
9. Validation of ApneaLink Ox™ for the diagnosis of obstructive sleep apnea. Nigro CA; Dibur E; Malnis S; Grandval S; Nogueira F Sleep Breath; 2013 Mar; 17(1):259-66. PubMed ID: 22447171 [TBL] [Abstract][Full Text] [Related]
11. Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea. Nigro CA; González S; Arce A; Aragone MR; Nigro L Sleep Breath; 2015 May; 19(2):569-78. PubMed ID: 25115886 [TBL] [Abstract][Full Text] [Related]
12. Response to CPAP withdrawal in patients with mild versus severe obstructive sleep apnea/hypopnea syndrome. Young LR; Taxin ZH; Norman RG; Walsleben JA; Rapoport DM; Ayappa I Sleep; 2013 Mar; 36(3):405-12. PubMed ID: 23449493 [TBL] [Abstract][Full Text] [Related]
13. Sleep-disordered breathing in the usual lifestyle setting as detected with home monitoring in a population of working men in Japan. Nakayama-Ashida Y; Takegami M; Chin K; Sumi K; Nakamura T; Takahashi K; Wakamura T; Horita S; Oka Y; Minami I; Fukuhara S; Kadotani H Sleep; 2008 Mar; 31(3):419-25. PubMed ID: 18363319 [TBL] [Abstract][Full Text] [Related]
14. Addition of frontal EEG to adult home sleep apnea testing: does a more accurate determination of sleep time make a difference? Light MP; Casimire TN; Chua C; Koushyk V; Burschtin OE; Ayappa I; Rapoport DM Sleep Breath; 2018 Dec; 22(4):1179-1188. PubMed ID: 30311183 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of a portable recording device (ApneaLink) for case selection of obstructive sleep apnea. Chen H; Lowe AA; Bai Y; Hamilton P; Fleetham JA; Almeida FR Sleep Breath; 2009 Aug; 13(3):213-9. PubMed ID: 19052790 [TBL] [Abstract][Full Text] [Related]
16. In-home evaluation of efficacy and titration of a mandibular advancement device for obstructive sleep apnea. Levendowski DJ; Morgan TD; Patrickus JE; Westbrook PR; Berka C; Zavora T; Popovic D Sleep Breath; 2007 Sep; 11(3):139-47. PubMed ID: 17235580 [TBL] [Abstract][Full Text] [Related]
17. Utility of ApneaLink for the diagnosis of sleep apnea-hypopnea syndrome. Nigro CA; Serrano F; Aimaretti S; González S; Codinardo C; Rhodius E Medicina (B Aires); 2010; 70(1):53-9. PubMed ID: 20228025 [TBL] [Abstract][Full Text] [Related]
18. Short-term variability of respiration and sleep during unattended nonlaboratory polysomnography--the Sleep Heart Health Study. [corrected]. Quan SF; Griswold ME; Iber C; Nieto FJ; Rapoport DM; Redline S; Sanders M; Young T; Sleep; 2002 Dec; 25(8):843-9. PubMed ID: 12489889 [TBL] [Abstract][Full Text] [Related]
19. [Utility of the type 3 portable monitor for the diagnosis of patients with obstructive sleep apnea]. Wen YF; Chang Y; Xu LY; Dong XS; Zhao L; Zhang XL; Li J; Zuo YH; Zhang W; Gao YH; Han F Zhonghua Yi Xue Za Zhi; 2019 Oct; 99(38):2994-2999. PubMed ID: 31607031 [No Abstract] [Full Text] [Related]