These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 1835137)

  • 21. [Study of myocardial perfusion at rest using technetium Tc 99m methoxy-isobutylisonitrile: comparison with labeled microspheres and thallium 201].
    Santoro GM; Bisi G; Sciagrà R; Antoniucci D; De Cristofaro MT; Dovellini EV; Pupi A; Zerauschek M; Fazzini PF
    G Ital Cardiol; 1988 Nov; 18(11):907-13. PubMed ID: 3266855
    [TBL] [Abstract][Full Text] [Related]  

  • 22. ECG-gated and static technetium-99m-SESTAMIBI planar myocardial perfusion imaging: a comparison with thallium-201 and study of observer variabilities.
    Verzijlbergen JF; Cramer MJ; Niemeyer MG; Ascoop CA; Van der Wall EE; Pauwels EK
    Am J Physiol Imaging; 1990; 5(2):60-7. PubMed ID: 2147553
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT.
    Maunoury C; Chen CC; Chua KB; Thompson CJ
    J Nucl Med; 1997 Jun; 38(6):958-61. PubMed ID: 9189150
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of myocardial ischemia using a rest metabolism/stress perfusion protocol with fluorine-18 deoxyglucose/technetium-99m MIBI and dual-isotope simultaneous-acquisition single-photon emission computed tomography.
    Sandler MP; Videlefsky S; Delbeke D; Patton JA; Meyerowitz C; Martin WH; Ohana I
    J Am Coll Cardiol; 1995 Oct; 26(4):870-8. PubMed ID: 7560611
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Usefulness of rapid low-dose/high-dose 1-day 99mTc-sestamibi ECG-gated myocardial perfusion single-photon emission computed tomography.
    Matsumoto N; Sato Y; Suzuki Y; Yoda S; Kunimasa T; Kato M; Tadehara F; Lewin HC; Hyun MC; Saito S
    Circ J; 2006 Dec; 70(12):1585-9. PubMed ID: 17127804
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Attenuation-corrected rest thallium-201/stress technetium 99m sestamibi myocardial SPECT in normals.
    Matsunari I; Böning G; Ziegler SI; Kosa I; Nekolla SG; Ficaro EP; Schwaiger M
    J Nucl Cardiol; 1998; 5(1):48-55. PubMed ID: 9504873
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Adenosine technetium-99m sestamibi myocardial perfusion SPECT in women: diagnostic efficacy in detection of coronary artery disease.
    Amanullah AM; Kiat H; Friedman JD; Berman DS
    J Am Coll Cardiol; 1996 Mar; 27(4):803-9. PubMed ID: 8613606
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Technetium-99m sestamibi myocardial imaging: same-day rest-stress studies and dipyridamole.
    Taillefer R
    Am J Cardiol; 1990 Oct; 66(13):80E-84E. PubMed ID: 2145751
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Diagnostic efficacy of stress technetium 99m-labeled sestamibi myocardial perfusion single-photon emission computed tomography in detection of coronary artery disease among patients over age 80.
    Wang FP; Amanullah AM; Kiat H; Friedman JD; Berman DS
    J Nucl Cardiol; 1995; 2(5):380-8. PubMed ID: 9420817
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging.
    Smanio PE; Watson DD; Segalla DL; Vinson EL; Smith WH; Beller GA
    J Am Coll Cardiol; 1997 Dec; 30(7):1687-92. PubMed ID: 9385894
    [TBL] [Abstract][Full Text] [Related]  

  • 31. State-of-the-art myocardial perfusion imaging.
    Maddahi J; Rodrigues E; Berman DS; Kiat H
    Cardiol Clin; 1994 May; 12(2):199-222. PubMed ID: 8033173
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Are technetium-99m-labeled myocardial perfusion agents adequate for detection of myocardial viability?
    Caner B; Beller GA
    Clin Cardiol; 1998 Apr; 21(4):235-42. PubMed ID: 9562932
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects.
    Siebelink HM; Natale D; Sinusas AJ; Wackers FJ
    J Nucl Cardiol; 1996; 3(6 Pt 1):483-93. PubMed ID: 8989673
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women.
    Taillefer R; DePuey EG; Udelson JE; Beller GA; Latour Y; Reeves F
    J Am Coll Cardiol; 1997 Jan; 29(1):69-77. PubMed ID: 8996297
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Myocardial viability in patients with chronic coronary artery disease. Comparison of 99mTc-sestamibi with thallium reinjection and [18F]fluorodeoxyglucose.
    Dilsizian V; Arrighi JA; Diodati JG; Quyyumi AA; Alavi K; Bacharach SL; Marin-Neto JA; Katsiyiannis PT; Bonow RO
    Circulation; 1994 Feb; 89(2):578-87. PubMed ID: 8313546
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.
    Hannequin P; Weinmann P; Mas J; Vinot S
    J Nucl Cardiol; 2001; 8(2):144-51. PubMed ID: 11295691
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of technetium-99m sestamibi left ventricular wall motion and perfusion studies with thallium-201 perfusion imaging: in search of the combination of variables with the highest accuracy in predicting coronary artery disease.
    Verzijlbergen JF; Zwinderman AH; Ascoop CA; van der Wall EE; Niemeyer MG; Pauwels EK
    Eur J Nucl Med; 1996 May; 23(5):550-9. PubMed ID: 8698061
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.
    Okudan B; Smitherman TC
    Anadolu Kardiyol Derg; 2004 Jun; 4(2):161-8. PubMed ID: 15165953
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Technetium-99m sestamibi in chronic coronary artery disease: the European experience.
    Sochor H
    Am J Cardiol; 1990 Oct; 66(13):91E-96E. PubMed ID: 2145754
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Simultaneous assessment of myocardial perfusion and ventricular function using thallium-201 at rest/Tc-99m tetrofosmin at effort with single-photon emission computerized tomography, synchronized with electrocardiogram (synchronized SPECT). Initial experience in Latin America].
    Puente A; Alexánderson E; Arroyo A; Lorenzo A; Victoria D
    Arch Inst Cardiol Mex; 2000; 70(5):448-55. PubMed ID: 11534095
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.