These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Optimizing precision of rotating-analyzer and rotating-compensator ellipsometers. Aspnes DE J Opt Soc Am A Opt Image Sci Vis; 2004 Mar; 21(3):403-10. PubMed ID: 15005405 [TBL] [Abstract][Full Text] [Related]
3. Optimization of polarizer azimuth in improving signal-to-noise ratio in Kerr microscopy. Wang X; Lian J; Xu XJ; Li X; Li P; Li MM; Wang Y; Liu YX Appl Opt; 2016 Mar; 55(7):1725-30. PubMed ID: 26974636 [TBL] [Abstract][Full Text] [Related]
4. Real-time characterization of film growth on transparent substrates by rotating-compensator multichannel ellipsometry. Lee J; Collins RW Appl Opt; 1998 Jul; 37(19):4230-8. PubMed ID: 18285868 [TBL] [Abstract][Full Text] [Related]
5. Optimization of azimuth angle settings in polarizer-compensator-sample-analyzer off-null ellipsometry. Wang G; Arwin H; Jansson R Appl Opt; 2003 Jan; 42(1):38-44. PubMed ID: 12518821 [TBL] [Abstract][Full Text] [Related]
6. Spectroscopic generalized ellipsometry based on fourier analysis. En Naciri A; Johann L; Kleim R Appl Opt; 1999 Aug; 38(22):4802-11. PubMed ID: 18323969 [TBL] [Abstract][Full Text] [Related]
7. Spectroscopic null ellipsometer using a variable retarder. Watkins LR; Shamailov SS Appl Opt; 2011 Jan; 50(1):50-2. PubMed ID: 21221159 [TBL] [Abstract][Full Text] [Related]
8. Analytical solutions of the azimuthal deviation of a polarizer and an analyzer by polarizer-sample-analyzer ellipsometry. Chao YF; Lee KY; Lin YD Appl Opt; 2006 Jun; 45(17):3935-9. PubMed ID: 16761030 [TBL] [Abstract][Full Text] [Related]
9. Error analysis of circular polarizer-analyzer systems for phase retardation measurements. Theofanous NG J Opt Soc Am A; 1987 Dec; 4(12):2191-200. PubMed ID: 3430212 [TBL] [Abstract][Full Text] [Related]
10. Design of a scanning ellipsometer by synchronous rotation of the polarizer and analyzer. Chen LY; Feng XW; Su Y; Ma HZ; Qian YH Appl Opt; 1994 Mar; 33(7):1299-305. PubMed ID: 20862155 [TBL] [Abstract][Full Text] [Related]
11. Spectroscopic ellipsometry of anisotropic materials: application to the optical constants of HgI2. En Naciri A; Johann L; Kleim R; Sieskind M; Amann M Appl Opt; 1999 Feb; 38(4):647-54. PubMed ID: 18305658 [TBL] [Abstract][Full Text] [Related]
12. Errors of Mueller matrix measurements with a partially polarized light source. Nee SM Appl Opt; 2006 Sep; 45(25):6497-506. PubMed ID: 16912788 [TBL] [Abstract][Full Text] [Related]
13. Spectroscopic ellipsometer based on direct measurement of polarization ellipticity. Watkins LR Appl Opt; 2011 Jun; 50(18):2973-8. PubMed ID: 21691363 [TBL] [Abstract][Full Text] [Related]
14. Optimization of off-null ellipsometry in sensor applications. Wang G; Arwin H; Jansson R Appl Opt; 2004 Apr; 43(10):2000-5. PubMed ID: 15074405 [TBL] [Abstract][Full Text] [Related]
15. Surface Effects of the HgI(2) Crystal Characterized by Spectroscopic Ellipsometry. En Naciri A; Johann L; Kleim R; Sieskind M; Amann M Appl Opt; 2001 Sep; 40(25):4519-25. PubMed ID: 18360492 [TBL] [Abstract][Full Text] [Related]
18. Determination of the optical function n(λ) of vitreous silica by spectroscopic ellipsometry with an achromatic compensator. Chindaudom P; Vedam K Appl Opt; 1993 Nov; 32(31):6391-8. PubMed ID: 20856477 [TBL] [Abstract][Full Text] [Related]